| SPDX-FileCopyrightText: © 2020 Open Networking Foundation <support@opennetworking.org> |
| SPDX-License-Identifier: Apache-2.0 |
| |
| General Procedures |
| ================== |
| |
| Edge shutdown procedure |
| ----------------------- |
| |
| To gracefully shutdown an Aether Edge Pod, follow the following steps: |
| |
| 1. Shutdown the fabric switches using ``shutdown -h now`` |
| |
| 2. Shutdown the compute servers using ``shutdown -h now`` |
| |
| 3. Shutdown the management server using ``shutdown -h now`` |
| |
| 4. The management switch and eNB aren't capable of a graceful shutdown, so no |
| steps need to be taken for that hardware. |
| |
| 5. Remove power from the pod. |
| |
| .. note:: |
| |
| The shutdown steps can be automated with an :doc:`ad-hoc ansible command |
| <ansible:user_guide/intro_adhoc>` and you have an ansible inventory of all |
| the systems:: |
| |
| ansible -i inventory/sitename.ini -b -m shutdown -a "delay=60" all |
| |
| The ``delay=60`` arg is to allow hosts behind the management server to be |
| reached before the management server shuts down. |
| |
| Edge power up procedure |
| ----------------------- |
| |
| 1. Restore power to the pod equipment. The fabric and management switches will |
| power on automatically. |
| |
| 2. Turn on the management server using the front panel power button |
| |
| 3. Turn on the compute servers using the front panel power buttons |