| --- |
| |
| # ----------------------------------------------------------------------- |
| # Copyright 2017-2024 Open Networking Foundation Contributors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http:#www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # ----------------------------------------------------------------------- |
| # SPDX-FileCopyrightText: 2017-2024 Open Networking Foundation Contributors |
| # SPDX-License-Identifier: Apache-2.0 |
| # ----------------------------------------------------------------------- |
| # Entropy: 0fcb5ffa-d1a4-11ee-be5e-9f44b7181764 |
| # ----------------------------------------------------------------------- |
| # Intent: voltha 2.0 tests, end-2-end pipeline jobs. |
| # ----------------------------------------------------------------------- |
| |
| - project: |
| name: voltha-e2e |
| |
| project-name: '{name}' |
| manualBranch: '' |
| olts: 1 |
| onus: 1 |
| pons: 1 |
| withAlarms: true |
| make-target-failtest: bbsim-failurescenarios |
| make-target-errortest: bbsim-errorscenarios |
| make-target-alarmtest: bbsim-alarms-kind |
| make-target-multipleolt: bbsim-multiolt-kind |
| make-target-1t4gemtest: 1t4gem-openonu-go-adapter-test |
| make-target-1t8gemtest: 1t8gem-openonu-go-adapter-test |
| make-target-reconciletest: reconcile-openonu-go-adapter-test-att |
| make-target-reconciledttest: reconcile-openonu-go-adapter-test-dt |
| make-target-reconciletttest: reconcile-openonu-go-adapter-test-tt |
| |
| jobs: |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multiple-olts-test-bbsim' |
| code-branch: 'master' |
| olts: 2 |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-multi-olt |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiolt-failurescenarios |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiolt-errorscenarios |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiolt-kind |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-multiple-olts-test-bbsim-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: 'voltha-2.8' |
| # olts: 2 |
| # extraHelmFlags: '--set onu=2,pon=2' |
| # time-trigger: "H H/23 * * *" |
| # testTargets: | |
| # - target: functional-multi-olt |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: bbsim-multiolt-failurescenarios |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| # - target: bbsim-multiolt-errorscenarios |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| # - target: bbsim-multiolt-kind |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multiple-olts-test-bbsim-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| olts: 2 |
| extraHelmFlags: '--set onu=2,pon=2' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-multi-olt |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiolt-failurescenarios |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiolt-errorscenarios |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiolt-kind |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multiple-olts-test-bbsim-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| olts: 2 |
| extraHelmFlags: '--set onu=2,pon=2' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-multi-olt |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiolt-failurescenarios |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiolt-errorscenarios |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiolt-kind |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multi-uni-test-bbsim' |
| code-branch: 'master' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-single-kind-multiuni-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiuni-failurescenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiuni-errorscenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multi-uni-multiple-olts-test-bbsim' |
| code-branch: 'master' |
| olts: 2 |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2 --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-multiuni-multiolt-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiuni-multiolt-failurescenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiuni-multiolt-errorscenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| timeout: 360 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-multi-uni-test-bbsim-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: 'voltha-2.8' |
| # extraHelmFlags: '--set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| # time-trigger: "H H/23 * * *" |
| # testTargets: | |
| # - target: functional-single-kind-multiuni-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: bbsim-multiuni-failurescenarios-att |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| # - target: bbsim-multiuni-errorscenarios-att |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multi-uni-test-bbsim-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| extraHelmFlags: '--set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-single-kind-multiuni-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiuni-failurescenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiuni-errorscenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multi-uni-test-bbsim-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| extraHelmFlags: '--set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-single-kind-multiuni-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiuni-failurescenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiuni-errorscenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-multi-uni-multiple-olts-test-bbsim-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: 'voltha-2.8' |
| # olts: 2 |
| # extraHelmFlags: '--set onu=2,pon=2 --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| # time-trigger: "H H/23 * * *" |
| # testTargets: | |
| # - target: functional-multiuni-multiolt-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: bbsim-multiuni-multiolt-failurescenarios-att |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| # - target: bbsim-multiuni-multiolt-errorscenarios-att |
| # workflow: att |
| # flags: "" |
| # teardown: false |
| # logging: true |
| # timeout: 180 |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multi-uni-multiple-olts-test-bbsim-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| olts: 2 |
| extraHelmFlags: '--set onu=2,pon=2 --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-multiuni-multiolt-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiuni-multiolt-failurescenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiuni-multiolt-errorscenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| timeout: 180 |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multi-uni-multiple-olts-test-bbsim-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| olts: 2 |
| extraHelmFlags: '--set onu=2,pon=2 --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: functional-multiuni-multiolt-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-multiuni-multiolt-failurescenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| - target: bbsim-multiuni-multiolt-errorscenarios-att |
| workflow: att |
| flags: "" |
| teardown: false |
| logging: true |
| timeout: 180 |
| |
| # ----------------------------------------------------------------------- |
| # openonu Go periodic tests |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-openonu-go-test-bbsim' |
| code-branch: 'master' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master' |
| time-trigger: "H H/12 * * *" |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: mib-upload-templating-openonu-go-adapter-test |
| workflow: att |
| flags: "--set pon=2,onu=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true --set global.extended_omci_support.enabled=true " |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-passed-test |
| workflow: att |
| flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-failed-test |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,omci_response_rate=7" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-att |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-tt |
| workflow: tt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-robustness-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1" |
| teardown: true |
| logging: true |
| - target: onu-robustness-test-multi-uni-kind-tt |
| workflow: tt |
| flags: "--set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF,kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1" |
| teardown: true |
| logging: true |
| timeout: 240 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-openonu-go-test-bbsim-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: 'voltha-2.8' |
| # time-trigger: "H H/23 * * *" |
| # logLevel: 'DEBUG' |
| # testTargets: | |
| # - target: 1t1gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t4gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t8gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: mib-upload-templating-openonu-go-adapter-test |
| # workflow: att |
| # flags: "--set pon=2,onu=2,controlledActivation=only-onu" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-test-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-test-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-test-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: openonu-go-adapter-omci-hardening-passed-test |
| # workflow: att |
| ################## flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| # teardown: true |
| # logging: true |
| # - target: openonu-go-adapter-omci-hardening-failed-test |
| # workflow: att |
| # flags: "--set omci_response_rate=7" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-single-kind-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-single-kind-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-single-kind-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-openonu-go-test-bbsim-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| time-trigger: "H H/23 * * *" |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: mib-upload-templating-openonu-go-adapter-test |
| workflow: att |
| flags: "--set pon=2,onu=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true --set global.extended_omci_support.enabled=true " |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-passed-test |
| workflow: att |
| flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-failed-test |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,omci_response_rate=7" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-att |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-tt |
| workflow: tt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-robustness-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1" |
| teardown: true |
| logging: true |
| - target: onu-robustness-test-multi-uni-kind-tt |
| workflow: tt |
| flags: "--set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF,kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1" |
| teardown: true |
| logging: true |
| timeout: 240 |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-openonu-go-test-bbsim-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| time-trigger: "H H/23 * * *" |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: mib-upload-templating-openonu-go-adapter-test |
| workflow: att |
| flags: "--set pon=2,onu=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true --set global.extended_omci_support.enabled=true " |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-passed-test |
| workflow: att |
| flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-failed-test |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,omci_response_rate=7" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-att |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-tt |
| workflow: tt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-robustness-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1" |
| teardown: true |
| logging: true |
| - target: onu-robustness-test-multi-uni-kind-tt |
| workflow: tt |
| flags: "--set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF,kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1" |
| teardown: true |
| logging: true |
| timeout: 240 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-openonu-go-test-bbsim' |
| trigger-comment: "voltha test openonu singleolt" |
| code-branch: '$GERRIT_BRANCH' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: mib-upload-templating-openonu-go-adapter-test |
| workflow: att |
| flags: "--set pon=2,onu=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true --set global.extended_omci_support.enabled=true " |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-passed-test |
| workflow: att |
| flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-failed-test |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,omci_response_rate=7" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-att |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-tt |
| workflow: tt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| timeout: 210 |
| |
| # - 'voltha-periodic-test': |
| # name: 'patchset-voltha-2.8-openonu-go-test-bbsim' |
| # trigger-comment: "voltha 2.8 test openonu singleolt" |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: '$GERRIT_BRANCH' |
| # gerritProject: '$GERRIT_PROJECT' |
| # gerritRefspec: '$GERRIT_REFSPEC' |
| # logLevel: 'DEBUG' |
| # testTargets: | |
| # - target: 1t1gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t4gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t8gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: mib-upload-templating-openonu-go-adapter-test |
| # workflow: att |
| # flags: "--set pon=2,onu=2,controlledActivation=only-onu" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-test-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-test-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-test-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: openonu-go-adapter-omci-hardening-passed-test |
| # workflow: att |
| ############## flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| # teardown: true |
| # logging: true |
| # - target: openonu-go-adapter-omci-hardening-failed-test |
| # workflow: att |
| # flags: "--set omci_response_rate=7" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-single-kind-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-single-kind-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-single-kind-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-2.11-openonu-go-test-bbsim' |
| trigger-comment: "voltha 2.11 test openonu singleolt" |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: '$GERRIT_BRANCH' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: mib-upload-templating-openonu-go-adapter-test |
| workflow: att |
| flags: "--set pon=2,onu=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true --set global.extended_omci_support.enabled=true " |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-passed-test |
| workflow: att |
| flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-failed-test |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,omci_response_rate=7" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-att |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-tt |
| workflow: tt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| timeout: 210 |
| |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-2.12-openonu-go-test-bbsim' |
| trigger-comment: "voltha 2.12 test openonu singleolt" |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: '$GERRIT_BRANCH' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: mib-upload-templating-openonu-go-adapter-test |
| workflow: att |
| flags: "--set pon=2,onu=2,controlledActivation=only-onu,injectOmciUnknownAttributes=true,injectOmciUnknownMe=true --set global.extended_omci_support.enabled=true " |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-passed-test |
| workflow: att |
| flags: "--set omci_response_rate=9 --set voltha-adapter-openonu.adapter_open_onu.omci_timeout=1s" |
| teardown: true |
| logging: true |
| - target: openonu-go-adapter-omci-hardening-failed-test |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,omci_response_rate=7" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-att |
| workflow: att |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-dt |
| workflow: dt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| - target: onu-mib-audit-test-single-kind-tt |
| workflow: tt |
| flags: "--set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1,voltha-adapter-openonu.global.mib_audit.interval=60s" |
| teardown: true |
| logging: true |
| timeout: 210 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multiple-olts-openonu-go-test-bbsim' |
| code-branch: 'master' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2' |
| olts: 2 |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| time-trigger: "H H/12 * * *" |
| timeout: 270 |
| |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-multiple-olts-openonu-go-test-bbsim-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: 'voltha-2.8' |
| # extraHelmFlags: '--set onu=2,pon=2' |
| # olts: 2 |
| # logLevel: 'DEBUG' |
| # testTargets: | |
| # - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-multi-olt-test-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-multiolt-kind-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-multiolt-kind-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-multiolt-kind-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # time-trigger: "H H/23 * * *" |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multiple-olts-openonu-go-test-bbsim-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| extraHelmFlags: '--set onu=2,pon=2' |
| olts: 2 |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| time-trigger: "H H/23 * * *" |
| timeout: 270 |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-multiple-olts-openonu-go-test-bbsim-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| extraHelmFlags: '--set onu=2,pon=2' |
| olts: 2 |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| time-trigger: "H H/23 * * *" |
| timeout: 270 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-multiple-olts-openonu-go-test-bbsim' |
| trigger-comment: "voltha test openonu multiolt" |
| code-branch: '$GERRIT_BRANCH' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| olts: 2 |
| timeout: 270 |
| |
| # - 'voltha-periodic-test': |
| # name: 'patchset-voltha-2.8-multiple-olts-openonu-go-test-bbsim' |
| # trigger-comment: "voltha 2.8 test openonu multiolt" |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: '$GERRIT_BRANCH' |
| # gerritProject: '$GERRIT_PROJECT' |
| # gerritRefspec: '$GERRIT_REFSPEC' |
| # extraHelmFlags: '--set onu=2,pon=2' |
| # olts: 2 |
| # logLevel: 'DEBUG' |
| # testTargets: | |
| # - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: reconcile-openonu-go-adapter-multi-olt-test-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-multiolt-kind-att |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-multiolt-kind-dt |
| # workflow: dt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| # - target: voltha-onu-omci-get-multiolt-kind-tt |
| # workflow: tt |
| # flags: "" |
| # teardown: true |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-2.11-multiple-olts-openonu-go-test-bbsim' |
| trigger-comment: "voltha 2.11 test openonu multiolt" |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: '$GERRIT_BRANCH' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| extraHelmFlags: '--set onu=2,pon=2' |
| olts: 2 |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| timeout: 270 |
| |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-2.12-multiple-olts-openonu-go-test-bbsim' |
| trigger-comment: "voltha 2.12 test openonu multiolt" |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: '$GERRIT_BRANCH' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| extraHelmFlags: '--set onu=2,pon=2' |
| olts: 2 |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: 1t1gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t4gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: 1t8gem-openonu-go-adapter-multi-olt-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-test-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: reconcile-openonu-go-adapter-multi-olt-multi-uni-test-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-omci-get-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-onu-flows-check-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| timeout: 270 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-pm-data-test-bbsim' |
| trigger-comment: "voltha test pm data singleolt" |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1' |
| code-branch: '$GERRIT_BRANCH' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: voltha-pm-data-single-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-pm-data-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-pm-data-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| timeout: 140 |
| ## YY |
| #----------------------------------------------------------------------- |
| # Intent: Pipeline jobs refactored into voltha-e2e/votlha-x.1x |
| # What to do with patchset-* (?) |
| #----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'patchset-voltha-multiple-olts-pm-data-test-bbsim' |
| trigger-comment: "voltha test pm data multiolt" |
| code-branch: '$GERRIT_BRANCH' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2 --set kafka.externalAccess.enabled=true,kafka.externalAccess.service.type=NodePort,kafka.externalAccess.service.nodePorts[0]=30201,kafka.externalAccess.service.domain=127.0.0.1' |
| gerritProject: '$GERRIT_PROJECT' |
| gerritRefspec: '$GERRIT_REFSPEC' |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: voltha-pm-data-multiolt-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-pm-data-multiolt-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: voltha-pm-data-multiolt-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| olts: 2 |
| timeout: 180 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-test-DMI' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master' |
| code-branch: 'master' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: bbsim-dmi-hw-management-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-test-DMI-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # code-branch: 'voltha-2.8' |
| # time-trigger: "H H/23 * * *" |
| # testTargets: | |
| # - target: bbsim-dmi-hw-management-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-test-DMI-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: bbsim-dmi-hw-management-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-test-DMI-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: bbsim-dmi-hw-management-test |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-etcd-test' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| code-branch: 'master' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2' |
| time-trigger: "H H/12 * * *" |
| testTargets: | |
| - target: sanity-multi-kind |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| |
| # - 'voltha-periodic-test': |
| # name: 'periodic-voltha-etcd-test-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/bbsim-tests.groovy' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| # code-branch: 'voltha-2.8' |
| # extraHelmFlags: '--set onu=2,pon=2' |
| # time-trigger: "H H/23 * * *" |
| # testTargets: | |
| # - target: sanity-multi-kind |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-etcd-test-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| code-branch: 'voltha-2.11' |
| extraHelmFlags: '--set onu=2,pon=2' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: sanity-multi-kind |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-etcd-test-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| code-branch: 'voltha-2.12' |
| extraHelmFlags: '--set onu=2,pon=2' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: sanity-multi-kind |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-unitag-subscriber-tt-test-bbsim' |
| code-branch: 'master' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onos-classic.replicas=3,onos-classic.atomix.replicas=3 --set voltha.onos_classic.replicas=3 ' |
| time-trigger: "H H/23 * * *" |
| logLevel: 'DEBUG' |
| robot-args: '-v unitag_sub:True' |
| testTargets: | |
| - target: functional-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-failurescenarios-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: functional-single-kind-multiuni-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-unitag-subscriber-tt-test-bbsim-2.12' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| extraHelmFlags: '--set onos-classic.replicas=3,onos-classic.atomix.replicas=3 --set voltha.onos_classic.replicas=3 ' |
| time-trigger: "H H/23 * * *" |
| logLevel: 'DEBUG' |
| robot-args: '-v unitag_sub:True' |
| testTargets: | |
| - target: functional-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-failurescenarios-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: functional-single-kind-multiuni-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-unitag-subscriber-tt-test-bbsim-2.11' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| extraHelmFlags: '--set onos-classic.replicas=3,onos-classic.atomix.replicas=3 --set voltha.onos_classic.replicas=3 ' |
| time-trigger: "H H/23 * * *" |
| logLevel: 'DEBUG' |
| robot-args: '-v unitag_sub:True' |
| testTargets: | |
| - target: functional-single-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: bbsim-failurescenarios-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: functional-single-kind-multiuni-tt |
| workflow: tt |
| flags: " --set voltha-adapter-openonu.adapter_open_onu.uni_port_mask=0x00FF " |
| teardown: true |
| logging: true |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-tt-maclearner-sanity-test-bbsim' |
| code-branch: 'master' |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onos-classic.replicas=3,onos-classic.atomix.replicas=3 --set voltha.onos_classic.replicas=3 ' |
| time-trigger: "H H/23 * * *" |
| logLevel: 'DEBUG' |
| enableMacLearning: true |
| testTargets: | |
| - target: sanity-kind-tt-maclearning |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| |
| # Attention: Due VOL-4703 is not corrected memory leak tests will run in pipeline for DT workflow only! |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-memory-leak-test-bbsim' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| code-branch: 'master' |
| time-trigger: "H H/23 * * *" |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,controlledActivation=only-onu' |
| withMonitoring: true |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: memory-leak-test-single-pon-multi-onu-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| timeout: 230 |
| |
| # ----------------------------------------------------------------------- |
| # ----------------------------------------------------------------------- |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-memory-leak-test-bbsim-2.12' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.12' |
| code-branch: 'voltha-2.12' |
| time-trigger: "H H/23 * * *" |
| withMonitoring: true |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: memory-leak-test-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| timeout: 230 |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-memory-leak-test-bbsim-2.11' |
| # build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| pipeline-script: 'voltha/voltha-2.11/bbsim-tests.groovy' |
| pipeline-branch: 'voltha-2.11' |
| code-branch: 'voltha-2.11' |
| time-trigger: "H H/23 * * *" |
| withMonitoring: true |
| logLevel: 'DEBUG' |
| testTargets: | |
| - target: memory-leak-test-single-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| timeout: 230 |
| |
| - 'voltha-periodic-test': |
| name: 'periodic-voltha-tim-multiple-olts-test-bbsim' |
| code-branch: 'master' |
| olts: 2 |
| extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set onu=2,pon=2' |
| time-trigger: "H H/23 * * *" |
| testTargets: | |
| - target: sanity-kind-tim-multi-olt-multi-pon-multi-onu |
| workflow: tim |
| flags: "" |
| teardown: true |
| logging: true |
| |
| # ATT Per-patchset Pod builds on Tucson pod (master) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_auto': |
| # name: 'verify_physical_voltha_patchset_auto' |
| # extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set global.log_level=debug' |
| # workflow: 'att' |
| # branch-pattern: master |
| |
| |
| # ATT Per-patchset Pod builds on Tucson pod (voltha-2.8) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_auto': |
| # name: 'verify_physical_voltha_patchset_auto-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/tucson-build-and-test.groovy' |
| # extraHelmFlags: '--set global.log_level=debug' |
| # workflow: 'att' |
| # branch-pattern: voltha-2.8 |
| |
| # ATT Per-patchset Pod builds on Tucson pod (voltha-2.11) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_auto': |
| # name: 'verify_physical_voltha_patchset_auto-2.11' |
| # pipeline-script: 'voltha/voltha-2.11/tucson-build-and-test.groovy' |
| # extraHelmFlags: '--set global.log_level=debug' |
| # workflow: 'att' |
| # branch-pattern: voltha-2.11 |
| |
| # ATT Manual Pod builds on Tucson pod (master) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_manual': |
| # name: 'verify_physical_voltha_patchset_manual' |
| # trigger-string: 'hardware test' |
| # branch-pattern: master |
| # extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set global.log_level=debug' |
| # workflow: 'att' |
| |
| # ATT Manual Pod builds on Tucson pod (voltha-2.8) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_manual': |
| # name: 'verify_physical_voltha_patchset_manual-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/tucson-build-and-test.groovy' |
| # trigger-string: 'hardware test' |
| # branch-pattern: voltha-2.8 |
| # extraHelmFlags: '--set global.log_level=debug' |
| # workflow: 'att' |
| |
| # ATT Manual Pod builds on Tucson pod (voltha-2.11) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_manual': |
| # name: 'verify_physical_voltha_patchset_manual-2.11' |
| # pipeline-script: 'voltha/voltha-2.11/tucson-build-and-test.groovy' |
| # trigger-string: 'hardware test' |
| # branch-pattern: voltha-2.11 |
| # extraHelmFlags: '--set global.log_level=debug' |
| # workflow: 'att' |
| |
| # DT Manual Pod builds on Tucson pod (master) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_manual': |
| # name: 'verify_physical_voltha_patchset_manual_DT' |
| # workflow: 'dt' |
| # trigger-string: 'DT hardware test' |
| # default-test-args: '-i sanityDt -i PowerSwitch -X' |
| # branch-pattern: master |
| # extraHelmFlags: '--set global.image_tag=master --set onos-classic.image.tag=master --set global.log_level=debug' |
| |
| # DT Manual Pod builds on Tucson pod (voltha-2.8) |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_manual': |
| # name: 'verify_physical_voltha_patchset_manual_DT-2.8' |
| # pipeline-script: 'voltha/voltha-2.8/tucson-build-and-test.groovy' |
| # workflow: 'dt' |
| # trigger-string: 'DT hardware test' |
| # default-test-args: '-i sanityDt -i PowerSwitch -X' |
| # branch-pattern: voltha-2.8 |
| # extraHelmFlags: '--set global.log_level=debug' |
| # DT Manual Pod builds on Tucson pod (voltha-2.8) |
| |
| # Disable Tucson pod jobs as the corresponding ASXVOLT16 OLT is bad and replacement is needed. |
| # The dev_mgmt_daemon process keeps crashing on this OLT and seems to be a hardware issue. Reenable |
| # the job when the OLT is replaced and everything works fine. |
| # - 'verify_physical_voltha_patchset_manual': |
| # name: 'verify_physical_voltha_patchset_manual_DT-2.11' |
| # pipeline-script: 'voltha/voltha-2.11/tucson-build-and-test.groovy' |
| # workflow: 'dt' |
| # trigger-string: 'DT hardware test' |
| # default-test-args: '-i sanityDt -i PowerSwitch -X' |
| # branch-pattern: voltha-2.11 |
| # extraHelmFlags: '--set global.log_level=debug' |
| |
| - job-template: |
| id: 'voltha-periodic-test' |
| name: '{name}' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'master' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| robot-args: '' |
| gerritProject: '' |
| gerritRefspec: '' |
| volthaSystemTestsChange: '' |
| volthaHelmChartsChange: '' |
| extraHelmFlags: '' |
| registry: mirror.registry.opennetworking.org |
| sandbox: true |
| olts: 1 |
| timeout: 130 |
| logLevel: 'INFO' |
| enableMacLearning: false |
| withMonitoring: false |
| |
| trigger-comment: vv7CBoQQYYonvaN8xcru |
| time-trigger: 0 0 29 2 * |
| |
| description: | |
| <!-- Managed by Jenkins Job Builder --> |
| Created by {id} job-template from ci-management/jjb/voltha-e2e.yaml <br /><br /> |
| E2E Validation for Voltha 2.X |
| |
| properties: |
| - onf-infra-volthadevs-permissions |
| - cord-infra-properties: |
| build-days-to-keep: '{big-build-days-to-keep}' |
| artifact-num-to-keep: '{big-artifact-num-to-keep}' |
| |
| wrappers: |
| - lf-infra-wrappers: |
| build-timeout: '{build-timeout}' |
| jenkins-ssh-credential: '{jenkins-ssh-credential}' |
| |
| parameters: |
| - string: |
| name: buildNode |
| default: '{build-node}' |
| description: 'Name of the Jenkins node to run the job on' |
| |
| - string: |
| name: extraHelmFlags |
| default: '{extraHelmFlags}' |
| description: 'Helm flags (passed to each deployment)' |
| |
| # test configuration |
| # this is a parameter to drive the test execution, VOLTHA is redeployed each time with |
| # the provided configuration and then the make target is invoked, |
| # example value (has to be valid YAML): |
| # testTargets: | |
| # - target: 1t1gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| - text: |
| name: testTargets |
| default: '{testTargets}' |
| description: 'Test configuration, see the ci-management job definition for more info' |
| |
| - string: |
| name: branch |
| default: '{code-branch}' |
| description: 'Repo manifest branch for code checkout' |
| |
| - string: |
| name: gerritProject |
| default: '{gerritProject}' |
| description: 'Name of the Gerrit project' |
| |
| - string: |
| name: gerritRefspec |
| default: '{gerritRefspec}' |
| description: 'PatchSet REFSPEC in Gerrit, example value: "refs/changes/79/18779/13"' |
| |
| # applicable for voltha-2.9 (excluding) onwards |
| - bool: |
| name: enableMacLearning |
| default: '{enableMacLearning}' |
| description: "Deploy and test with ONOS Mac-Learning app" |
| |
| - string: |
| name: extraRobotArgs |
| default: '{robot-args}' |
| description: 'Arguments to pass to robot' |
| |
| - string: |
| name: volthaSystemTestsChange |
| default: '{volthaSystemTestsChange}' |
| description: 'Download a change for gerrit in the voltha-system-tests repo, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: volthaHelmChartsChange |
| default: '{volthaHelmChartsChange}' |
| description: 'Download a change for gerrit in the voltha-helm-charts repo, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: olts |
| default: '{olts}' |
| description: 'How many BBSim instances to run' |
| |
| - string: |
| name: registry |
| default: '{registry}' |
| description: 'Which registry to use (amazon vs menlo)' |
| |
| - string: |
| name: logLevel |
| default: '{logLevel}' |
| description: 'Log level for all the components' |
| |
| - bool: |
| name: withMonitoring |
| default: '{withMonitoring}' |
| description: 'Option to install Prometheus' |
| |
| - string: |
| name: timeout |
| default: '{timeout}' |
| description: 'Timeout of pipeline job [minutes]' |
| |
| project-type: pipeline |
| concurrent: true |
| |
| pipeline-scm: |
| scm: |
| - git: |
| url: https://gerrit.opencord.org/ci-management |
| branches: |
| - origin/{pipeline-branch} |
| script-path: jjb/pipeline/{pipeline-script} |
| |
| triggers: |
| # patchset jobs will set this to "0 0 29 2 *" (feb 29th, it's once every 4 years) |
| - timed: | |
| TZ=America/Los_Angeles |
| {time-trigger} |
| # periodic jobs will set this to vv7CBoQQYYonvaN8xcru (hopefully no-one will comment with that) |
| - gerrit: |
| server-name: '{gerrit-server-name}' |
| silent-start: false |
| successful-message: "PASSED openonu-go test" |
| failure-message: "FAILED openonu-go test" |
| unstable-message: "UNSTABLE openonu-go test" |
| trigger-on: |
| - comment-added-contains-event: |
| comment-contains-value: '.*{trigger-comment}.*' |
| projects: |
| - project-compare-type: REG_EXP |
| project-pattern: '^(voltha-go|voltha-openolt-adapter|voltha-openonu-adapter-go|ofagent-go|voltha-onos|bbsim)$' |
| branches: |
| - branch-compare-type: REG_EXP |
| branch-pattern: '{all-branches-regexp}' |
| |
| - job-template: |
| id: 'voltha-patch-test' |
| name: 'verify_{project}_sanity-test{name-extension}' |
| #build-node: 'ubuntu18.04-basebuild-4c-8g' |
| build-node: 'ubuntu18.04-basebuild-8c-15g' |
| pipeline-script: 'voltha/bbsim-tests.groovy' |
| pipeline-branch: 'master' |
| override-branch: '$GERRIT_BRANCH' |
| sandbox: true |
| build-timeout: 20 |
| timeout: 50 |
| olts: 1 |
| registry: mirror.registry.opennetworking.org |
| logLevel: 'INFO' |
| volthaSystemTestsChange: '' |
| volthaHelmChartsChange: '' |
| extraHelmFlags: '' |
| enableMacLearning: false |
| withMonitoring: false |
| robot-args: '' |
| branch-regexp: '{all-branches-regexp}' |
| testTargets: | |
| - target: sanity-kind-att |
| workflow: att |
| flags: "" |
| teardown: true |
| logging: true |
| - target: sanity-kind-dt |
| workflow: dt |
| flags: "" |
| teardown: true |
| logging: true |
| - target: sanity-kind-tt |
| workflow: tt |
| flags: "" |
| teardown: true |
| logging: true |
| |
| description: | |
| <!-- Managed by Jenkins Job Builder --> |
| Created by {id} job-template from ci-management/jjb/voltha-e2e.yaml <br /><br /> |
| E2E Validation for Voltha 2.X |
| |
| properties: |
| - onf-infra-volthadevs-permissions |
| - cord-infra-properties: |
| build-days-to-keep: '{build-days-to-keep}' |
| artifact-num-to-keep: '{artifact-num-to-keep}' |
| |
| wrappers: |
| - lf-infra-wrappers: |
| build-timeout: '{build-timeout}' |
| jenkins-ssh-credential: '{jenkins-ssh-credential}' |
| |
| parameters: |
| - string: |
| name: buildNode |
| default: '{build-node}' |
| description: 'Name of the Jenkins node to run the job on' |
| |
| - string: |
| name: gerritProject |
| default: '$GERRIT_PROJECT' |
| description: 'Name of the Gerrit project' |
| |
| - string: |
| name: gerritRefspec |
| default: '$GERRIT_REFSPEC' |
| description: 'PatchSet REFSPEC in Gerrit, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: extraHelmFlags |
| default: '{extraHelmFlags}' |
| description: 'Helm flags to pass to every helm command' |
| |
| # applicable for voltha-2.9 (excluding) onwards |
| - bool: |
| name: enableMacLearning |
| default: '{enableMacLearning}' |
| description: "Deploy and test with ONOS Mac-Learning app" |
| |
| - string: |
| name: extraRobotArgs |
| default: '{robot-args}' |
| description: 'Arguments to pass to robot' |
| |
| - string: |
| name: volthaSystemTestsChange |
| default: '{volthaSystemTestsChange}' |
| description: 'Download a change for gerrit in the voltha-system-tests repo, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: volthaHelmChartsChange |
| default: '{volthaHelmChartsChange}' |
| description: 'Download a change for gerrit in the voltha-helm-charts repo, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: branch |
| default: '{override-branch}' |
| description: 'Name of the branch to use' |
| |
| # test configuration |
| # this is a parameter to drive the test execution, VOLTHA is redeployed each time with |
| # the provided configuration and then the make target is invoked, |
| # example value (has to be valid YAML): |
| # testTargets: | |
| # - target: 1t1gem-openonu-go-adapter-test |
| # workflow: att |
| # flags: "" |
| # teardown: true |
| # logging: true |
| - text: |
| name: testTargets |
| default: '{testTargets}' |
| description: 'Test configuration, see the ci-management job definition for more info' |
| |
| - string: |
| name: timeout |
| default: '{timeout}' |
| description: 'Timeout of pipeline job [minutes]' |
| |
| - string: |
| name: olts |
| default: '{olts}' |
| description: 'How many BBSim instances to run' |
| |
| - string: |
| name: registry |
| default: '{registry}' |
| description: 'Which registry to use (amazon vs menlo)' |
| |
| - bool: |
| name: withMonitoring |
| default: '{withMonitoring}' |
| description: 'Option to install Prometheus' |
| |
| - string: |
| name: logLevel |
| default: '{logLevel}' |
| description: 'Log level for all the components' |
| |
| project-type: pipeline |
| concurrent: true |
| |
| pipeline-scm: |
| scm: |
| - git: |
| url: https://gerrit.opencord.org/ci-management |
| branches: |
| - origin/{pipeline-branch} |
| script-path: jjb/pipeline/{pipeline-script} |
| |
| triggers: |
| - gerrit: |
| server-name: '{gerrit-server-name}' |
| dependency-jobs: '{dependency-jobs}' |
| silent-start: true |
| trigger-on: |
| - patchset-created-event: |
| exclude-drafts: true |
| exclude-trivial-rebase: false |
| exclude-no-code-change: true |
| - draft-published-event |
| - comment-added-contains-event: |
| comment-contains-value: '(?i)^.*recheck$' |
| projects: |
| - project-compare-type: REG_EXP |
| project-pattern: '^{project}$' |
| branches: |
| - branch-compare-type: REG_EXP |
| branch-pattern: '{branch-regexp}' |
| file-paths: |
| - compare-type: REG_EXP |
| pattern: '{all-files-regexp}' |
| |
| # POD Per Patchset Pipeline Jobs |
| # to use these parameters in a job: `<<: *voltha-physical-patchset-parameters` |
| - voltha-physical-patchset-parameters: &voltha-physical-patchset-parameters |
| name: voltha-physical-patchset-parameters |
| parameters: |
| - string: |
| name: buildNode |
| default: '{build-node}' |
| description: 'Pod management node' |
| |
| - string: |
| name: branch |
| default: '$GERRIT_BRANCH' |
| description: 'Name of the repo branch to use' |
| |
| - string: |
| name: gerritProject |
| default: '$GERRIT_PROJECT' |
| description: 'Name of the Gerrit project' |
| |
| - string: |
| name: gerritRefspec |
| default: '$GERRIT_REFSPEC' |
| description: 'RefSpec number in Gerrit' |
| |
| - string: |
| name: gerritComment |
| default: '$GERRIT_EVENT_COMMENT_TEXT' |
| description: 'RefSpec number in Gerrit' |
| |
| - string: |
| name: cordRepoUrl |
| default: '{gerrit-server-url}' |
| description: 'The URL of the CORD Project repository' |
| |
| - string: |
| name: configBaseDir |
| default: 'pod-configs' |
| description: 'The directory inside the POD configs repository' |
| |
| - string: |
| name: configDeploymentDir |
| default: 'deployment-configs' |
| description: 'The deployment configs folder' |
| |
| - string: |
| name: configKubernetesDir |
| default: 'kubernetes-configs' |
| description: 'The kubernetes config folder' |
| |
| - string: |
| name: configFileName |
| default: '{config-pod}' |
| description: 'The config file' |
| |
| - string: |
| name: podName |
| default: '{config-pod}' |
| |
| - string: |
| name: sadisConfigFile |
| default: 'voltha-system-tests/tests/data/{config-pod}-sadis.json' |
| description: 'Path of SADIS config to load' |
| |
| - string: |
| name: oltDebVersionMaster |
| default: '{oltDebVersionMaster}' |
| description: 'OLT Software version to install for master branch builds' |
| |
| - string: |
| name: oltDebVersionVoltha23 |
| default: '{oltDebVersionVoltha23}' |
| description: 'OLT Software version to install for voltha-2.3 branch builds' |
| |
| - string: |
| name: profile |
| default: '{profile}' |
| description: 'Technology Profile pushed to the ETCD' |
| |
| - bool: |
| name: reinstallOlt |
| default: true |
| description: "Re-install OLT software" |
| |
| - string: |
| name: extraRobotArgs |
| default: '{default-test-args}' |
| description: 'Arguments to pass to robot' |
| |
| - string: |
| name: volthaSystemTestsChange |
| default: '{volthaSystemTestsChange}' |
| description: 'Download a change for gerrit in the voltha-system-tests repo, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: volthaHelmChartsChange |
| default: '{volthaHelmChartsChange}' |
| description: 'Download a change for gerrit in the voltha-helm-charts repo, example value: "refs/changes/79/18779/13"' |
| |
| - string: |
| name: workflow |
| default: '{workflow}' |
| description: 'Installs and uses the specified work flow on the POD' |
| |
| - string: |
| name: extraHelmFlags |
| default: '{extraHelmFlags}' |
| description: 'Helm flags (passed to each helm command)' |
| |
| # deprecated parameters, remove after VOLTHA-2.8 is released |
| - string: |
| name: deploymentConfigFile |
| default: 'pod-configs/deployment-configs/{config-pod}.yaml' |
| description: 'Path of deployment config file' |
| |
| - string: |
| name: kindVolthaValuesFile |
| default: 'pod-configs/kubernetes-configs/voltha/{config-pod}.yml' |
| description: 'Path of kind-voltha values override file' |
| |
| - string: |
| name: manifestUrl |
| default: '{gerrit-server-url}/{voltha-test-manifest-repo}' |
| description: 'URL to the repo manifest' |
| |
| - string: |
| name: gerritChangeNumber |
| default: '$GERRIT_CHANGE_NUMBER' |
| description: 'Changeset number in Gerrit' |
| |
| - string: |
| name: gerritPatchsetNumber |
| default: '$GERRIT_PATCHSET_NUMBER' |
| description: 'PatchSet number in Gerrit' |
| |
| - string: |
| name: localConfigDir |
| default: null |
| description: 'If specified, config file paths are relative to this dir; otherwise $WORKSPACE' |
| |
| - string: |
| name: configRepo |
| default: 'pod-configs' |
| description: 'A repository containing the config files, will be checked out if specified' |
| |
| - string: |
| name: manualBranch |
| default: '{manualBranch}' |
| description: "If a non-empty string, build manually as a specific branch, not with a specific patchset" |
| |
| - job-template: |
| name: '{name}' |
| id: verify_physical_voltha_patchset_auto |
| description: | |
| <!-- Managed by Jenkins Job Builder --> |
| Automated build on POD {config-pod} using {pipeline-script} <br /><br /> |
| Created from job-template {id} from ci-management/jjb/voltha-e2e.yaml <br /> |
| Created by Andy Bavier, andy@opennetworking.org <br /> |
| Copyright 2019-2024 Open Networking Foundation (ONF) and the ONF Contributors |
| sandbox: true |
| pipeline-script: 'voltha/tucson-build-and-test.groovy' |
| pipeline-branch: 'master' |
| default-test-args: '-i sanityORDeleteOLT -i PowerSwitch -X' |
| build-node: 'tucson-pod' |
| config-pod: 'tucson-pod' |
| profile: 'Default' |
| oltDebVersionMaster: 'openolt_asfvolt16-3.7.4-3b190f027136e845c5850a5b1a97897ce2b74ebf-40G-NNI.deb' |
| oltDebVersionVoltha23: 'openolt_asfvolt16-3.4.9-e2a9597f3d690fe3a0ea0df244571dfc9e8c2833-40G-NNI.deb' |
| volthaSystemTestsChange: '' |
| volthaHelmChartsChange: '' |
| extraHelmFlags: '' |
| |
| properties: |
| - onf-infra-volthadevs-permissions |
| - cord-infra-properties: |
| build-days-to-keep: '{build-days-to-keep}' |
| artifact-num-to-keep: '{artifact-num-to-keep}' |
| |
| <<: *voltha-physical-patchset-parameters |
| |
| project-type: pipeline |
| concurrent: true |
| |
| pipeline-scm: |
| scm: |
| - git: |
| url: https://gerrit.opencord.org/ci-management |
| branches: |
| - origin/{pipeline-branch} |
| script-path: jjb/pipeline/{pipeline-script} |
| |
| |
| triggers: |
| - gerrit: |
| server-name: '{gerrit-server-name}' |
| dependency-jobs: '{dependency-jobs}' |
| silent-start: false |
| successful-message: "PASSED hardware test" |
| failure-message: "FAILED hardware test" |
| unstable-message: "UNSTABLE hardware test" |
| trigger-on: |
| - comment-added-event: |
| approval-category: 'Code-Review' |
| approval-value: '+2' |
| projects: |
| - project-compare-type: REG_EXP |
| project-pattern: '^(voltha-openolt-adapter|voltha-openonu-adapter|voltha-openonu-adapter-go|voltha-go)$' |
| branches: |
| - branch-compare-type: REG_EXP |
| branch-pattern: '{branch-pattern}' |
| |
| - job-template: |
| name: '{name}' |
| id: verify_physical_voltha_patchset_manual |
| description: | |
| <!-- Managed by Jenkins Job Builder --> |
| Automated build on POD {config-pod} using {pipeline-script} <br /><br /> |
| Created from job-template {id} from ci-management/jjb/voltha-e2e.yaml <br /> |
| Created by Andy Bavier, andy@opennetworking.org <br /> |
| Copyright 2019-2024 Open Networking Foundation (ONF) and the ONF Contributors |
| sandbox: true |
| build-node: 'tucson-pod' |
| config-pod: 'tucson-pod' |
| oltDebVersionMaster: 'openolt_asfvolt16-3.7.4-3b190f027136e845c5850a5b1a97897ce2b74ebf-40G-NNI.deb' |
| oltDebVersionVoltha23: 'openolt_asfvolt16-3.4.9-e2a9597f3d690fe3a0ea0df244571dfc9e8c2833-40G-NNI.deb' |
| pipeline-script: 'voltha/tucson-build-and-test.groovy' |
| pipeline-branch: 'master' |
| trigger-string: 'hardware test' |
| default-test-args: '-i sanityORDeleteOLT -i PowerSwitch -X' |
| volthaSystemTestsChange: '' |
| volthaHelmChartsChange: '' |
| profile: 'Default' |
| extraHelmFlags: '' |
| |
| properties: |
| - onf-infra-volthadevs-permissions |
| - cord-infra-properties: |
| build-days-to-keep: '{build-days-to-keep}' |
| artifact-num-to-keep: '{artifact-num-to-keep}' |
| |
| <<: *voltha-physical-patchset-parameters |
| |
| |
| project-type: pipeline |
| concurrent: true |
| |
| pipeline-scm: |
| scm: |
| - git: |
| url: https://gerrit.opencord.org/ci-management |
| branches: |
| - origin/{pipeline-branch} |
| script-path: jjb/pipeline/{pipeline-script} |
| |
| triggers: |
| - gerrit: |
| server-name: '{gerrit-server-name}' |
| dependency-jobs: '{dependency-jobs}' |
| silent-start: false |
| successful-message: "PASSED {trigger-string}" |
| failure-message: "FAILED {trigger-string}" |
| unstable-message: "UNSTABLE {trigger-string}" |
| trigger-on: |
| - comment-added-contains-event: |
| comment-contains-value: '^{trigger-string}$' |
| - comment-added-contains-event: |
| comment-contains-value: '^{trigger-string} with delay$' |
| projects: |
| - project-compare-type: REG_EXP |
| project-pattern: '^(voltha-go|voltha-openolt-adapter|voltha-openonu-adapter|voltha-openonu-adapter-go|voltha-api-server|voltha-system-tests|ofagent-py|ofagent-go|voltha-onos|kind-voltha|voltha-helm-charts)$' |
| branches: |
| - branch-compare-type: REG_EXP |
| branch-pattern: '{branch-pattern}' |
| |
| # [EOF] |