| # Copyright 2017-present Open Networking Foundation |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| --- |
| kind: DaemonSet |
| apiVersion: apps/v1 |
| metadata: |
| name: sriov-device-plugin |
| namespace: kube-system |
| spec: |
| selector: |
| matchLabels: |
| name: sriov-device-plugin |
| template: |
| metadata: |
| labels: |
| name: sriov-device-plugin |
| spec: |
| serviceAccountName: sriov-dp |
| initContainers: |
| - name: init-sriov-dp |
| image: ngick8stesting/aio-cni:k8s-1.13 |
| command: [ "bash", "-c" ] |
| args: |
| - cp /tmp/cni/bin/{multus,sriov,centralip} /host/opt/cni/bin/; |
| echo "Restarting crio/containerd, kubelet"; |
| systemctl daemon-reload; |
| systemctl restart containerd; |
| systemctl restart crio; |
| systemctl restart kubelet; |
| volumeMounts: |
| - name: usr-bin |
| mountPath: /host/usr/bin |
| - name: cni-bin |
| mountPath: /host/opt/cni/bin |
| - name: multus-cm |
| mountPath: /tmp/etc/cni/net.d |
| - name: multus-certs |
| mountPath: /tmp/multus |
| - name: cni-conf |
| mountPath: /host/etc/cni/net.d |
| - name: dbus |
| mountPath: /var/run/dbus |
| - name: systemd |
| mountPath: /run/systemd |
| containers: |
| - name: sriov-device-plugin |
| image: ngick8stesting/aio-cni:k8s-1.13 |
| imagePullPolicy: IfNotPresent |
| command: [ "/bin/sh", "-c" ] |
| args: |
| - /usr/bin/sriovdp --logtostderr -v 10; |
| echo "exit status $?"; |
| volumeMounts: |
| - mountPath: /var/lib/kubelet/device-plugins/ |
| name: devicesock |
| readOnly: false |
| - mountPath: /sys/class/net/ |
| name: net |
| readOnly: true |
| - mountPath: /etc/pcidp/ |
| name: sriov-config |
| readOnly: false |
| volumes: |
| - name: sriov-config |
| configMap: |
| name: sriov-config |
| - name: usr-bin |
| hostPath: |
| path: /usr/bin |
| - name: cni-bin |
| hostPath: |
| path: /opt/cni/bin |
| - name: multus-cm |
| configMap: |
| name: multus-conf |
| - name: multus-certs |
| configMap: |
| defaultMode: 511 |
| name: multus-certs |
| - name: cni-conf |
| hostPath: |
| path: /etc/cni/net.d |
| - name: dbus |
| hostPath: |
| path: /var/run/dbus |
| - name: systemd |
| hostPath: |
| path: /run/systemd |
| - name: net |
| hostPath: |
| path: /sys/class/net |
| - name: devicesock |
| hostPath: |
| path: /var/lib/kubelet/device-plugins/ |
| hostNetwork: true |
| hostPID: true |