| option name = "volt"; |
| |
| message VOLTService (Service){ |
| option verbose_name = "vOLT Service"; |
| option kind = "vOLT"; |
| } |
| |
| message VOLTTenant (ServiceInstance){ |
| option kind = "vOLT"; |
| option verbose_name = "vOLT Tenant"; |
| |
| optional int32 s_tag = 1 [help_text = "s-tag", null = True, db_index = False, blank = True]; |
| optional int32 c_tag = 2 [help_text = "c-tag", null = True, db_index = False, blank = True]; |
| optional manytoone creator->User:created_volts = 3 [db_index = True, null = True, blank = True]; |
| } |
| |
| message AccessAgent (XOSBase){ |
| option verbose_name = "Access Agent"; |
| |
| required string name = 1 [help_text = "name of agent", max_length = 254, null = False, db_index = False, blank = False]; |
| required manytoone volt_service->VOLTService:access_agents = 2 [db_index = True, null = False, blank = False]; |
| optional string mac = 3 [help_text = "MAC Address or Access Agent", max_length = 32, null = True, db_index = False, blank = True]; |
| } |
| |
| message VOLTDevice (XOSBase){ |
| option verbose_name = "vOLT Device"; |
| |
| required string name = 1 [help_text = "name of device", max_length = 254, null = False, db_index = False, blank = False]; |
| required manytoone volt_service->VOLTService:volt_devices = 2 [db_index = True, null = False, blank = False]; |
| optional string openflow_id = 3 [help_text = "OpenFlow ID", max_length = 254, null = True, db_index = False, blank = True]; |
| optional string driver = 4 [help_text = "driver", max_length = 254, null = True, db_index = False, blank = True]; |
| optional manytoone access_agent->AccessAgent:volt_devices = 5 [db_index = True, null = True, blank = True]; |
| } |
| |
| message AccessDevice (XOSBase){ |
| option verbose_name = "Access Device"; |
| |
| required manytoone volt_device->VOLTDevice:access_devices = 1 [db_index = True, null = False, blank = False]; |
| optional int32 uplink = 2 [db_index = False, null = True, blank = True]; |
| optional int32 vlan = 3 [db_index = False, null = True, blank = True]; |
| } |
| |
| message AgentPortMapping (XOSBase){ |
| option verbose_name = "Agent Port Mapping"; |
| |
| required manytoone access_agent->AccessAgent:port_mappings = 1 [db_index = True, null = False, blank = False]; |
| optional string mac = 2 [help_text = "MAC Address", max_length = 32, null = True, db_index = False, blank = True]; |
| optional string port = 3 [help_text = "Openflow port ID", max_length = 32, null = True, db_index = False, blank = True]; |
| } |