blob: 75d0106d88be723c97756d486b2b737ba936433d [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// Dot1AgChassisManagementInfoClassID is the 16-bit ID for the OMCI
// Managed entity Dot1ag chassis-management info
const Dot1AgChassisManagementInfoClassID = ClassID(306) // 0x0132
var dot1agchassismanagementinfoBME *ManagedEntityDefinition
// Dot1AgChassisManagementInfo (Class ID: #306 / 0x0132)
// This ME represents the system-level chassis ID or management address for [IEEE-802.1ag] CFM
// messages, and potentially for other IEEE 802-based functions. Although [IEEE-802.1AB] allows for
// several management addresses (synonyms in different formats or with granularity to the component
// level), [IEEE-802.1ag] does not provide for more than one. Nor is it expected that an ONU would
// require more than one format. Accordingly, this ME provides for only one.
//
// According to sender ID permission attributes in several dot1ag MEs, transmitted IEEE-802.1ag CFM
// messages may include either or both of the chassis ID or management address
// fields.[IEEE-802.1ag] requires that CCMs do not exceed 128-bytes, of which 74 are separately
// allocated to other purposes; the sender ID TLV, if present, must accommodate this requirement.
// The chassis info and management info must fit, with a minimum of 4 additional overhead bytes,
// into the remaining 54-bytes. This limit is exploited in defining the maximum size of the ME's
// attributes.
//
// Relationships
// If an ONU supports [IEEE 802.1ag] functionality, it automatically creates an instance of this
// ME.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies this ME. There is at most one instance, whose value is 0. (R)
// (mandatory) (2-bytes)
//
// Chassis Id Length
// The length of the chassis ID attribute (not including the chassis ID subtype attribute), default
// value 0. (R,-W) (mandatory) (1-byte)
//
// Chassis Id Subtype
// The format of the chassis ID attribute, default value 7, as defined in [IEEE 802.1AB]:
//
// (R,-W) (mandatory) (1-byte)
//
// Chassis ID Part 1
// These two attributes may be regarded as an octet string of up to 50-bytes whose length is given
// by the chassis ID length attribute and whose value is the left-justified chassis ID. (R,-W)
// (mandatory) (25-bytes-*-2 attributes)
//
// Chassis ID Part 2
// These two attributes may be regarded as an octet string of up to 50-bytes whose length is given
// by the chassis ID length attribute and whose value is the left-justified chassis ID. (R,-W)
// (mandatory) (25-bytes-*-2 attributes)
//
// Management Address Domain Length
// The length of the management address domain attribute, default value 0. If this attribute has
// the value 0, all of the other management address attributes are undefined. (R,-W) (mandatory)
// (1-byte)
//
// Management Address Domain 1
// These two attributes may be regarded as an octet string of up to 50-bytes whose length is given
// by the management address domain length attribute and whose value is the left-justified
// management address domain. The attribute is coded as an object identifier (OID) as per [ITUT
// X.690], referring to a TDomain as defined in [IETF RFC 2579]. Typical domain values include
// snmpUDPDomain (from SNMPv2-TM [IETF RFC 3417]) and snmpIeee802Domain (from SNMP-IEEE 802-TM-MIB
// [IETF RFC 4789]). (R,-W) (mandatory) (25-bytes * 2 attributes)
//
// Management Address Domain 2
// These two attributes may be regarded as an octet string of up to 50-bytes whose length is given
// by the management address domain length attribute and whose value is the left-justified
// management address domain. The attribute is coded as an object identifier (OID) as per [ITUT
// X.690], referring to a TDomain as defined in [IETF RFC 2579]. Typical domain values include
// snmpUDPDomain (from SNMPv2-TM [IETF RFC 3417]) and snmpIeee802Domain (from SNMP-IEEE 802-TM-MIB
// [IETF RFC 4789]). (R,-W) (mandatory) (25-bytes * 2 attributes)
//
// Management Address Length
// The length of the management address attribute, default value 0. (R,-W) (mandatory) (1-byte)
//
// Management Address 1
// These two attributes may be regarded as an octet string of up to 50-bytes whose length is given
// by the management address length attribute and whose value is the left-justified management
// address. (R,-W) (mandatory) (25-bytes * 2 attributes)
//
// Management Address 2
// These two attributes may be regarded as an octet string of up to 50-bytes whose length is given
// by the management address length attribute and whose value is the left-justified management
// address. (R,-W) (mandatory) (25-bytes * 2 attributes)
//
type Dot1AgChassisManagementInfo struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
dot1agchassismanagementinfoBME = &ManagedEntityDefinition{
Name: "Dot1AgChassisManagementInfo",
ClassID: 306,
MessageTypes: mapset.NewSetWith(
Get,
Set,
),
AllowedAttributeMask: 0xffc0,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
1: ByteField("ChassisIdLength", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1),
2: ByteField("ChassisIdSubtype", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, false, false, 2),
3: MultiByteField("ChassisIdPart1", OctetsAttributeType, 0x2000, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, false, false, 3),
4: MultiByteField("ChassisIdPart2", OctetsAttributeType, 0x1000, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, false, false, 4),
5: ByteField("ManagementAddressDomainLength", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5),
6: MultiByteField("ManagementAddressDomain1", OctetsAttributeType, 0x0400, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, false, false, 6),
7: MultiByteField("ManagementAddressDomain2", OctetsAttributeType, 0x0200, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, false, false, 7),
8: ByteField("ManagementAddressLength", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, false, false, 8),
9: MultiByteField("ManagementAddress1", OctetsAttributeType, 0x0080, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, false, false, 9),
10: MultiByteField("ManagementAddress2", OctetsAttributeType, 0x0040, 25, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, false, false, 10),
},
Access: CreatedByOnu,
Support: UnknownSupport,
}
}
// NewDot1AgChassisManagementInfo (class ID 306) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewDot1AgChassisManagementInfo(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*dot1agchassismanagementinfoBME, params...)
}