| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // PwAtmPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI |
| // Managed entity PW ATM performance monitoring history data |
| const PwAtmPerformanceMonitoringHistoryDataClassID = ClassID(338) // 0x0152 |
| |
| var pwatmperformancemonitoringhistorydataBME *ManagedEntityDefinition |
| |
| // PwAtmPerformanceMonitoringHistoryData (Class ID: #338 / 0x0152) |
| // This ME collects PM data associated with an ATM pseudowire. Instances of this ME are created and |
| // deleted by the OLT. |
| // |
| // For a complete discussion of generic PM architecture, refer to clause I.4. |
| // |
| // Relationships |
| // An instance of this ME is associated with an instance of the PW ATM configuration data ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is |
| // implicitly linked to the instance of the PW ATM configuration data ME. (R, setbycreate) |
| // (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Downstream Missing Packets Counter |
| // This attribute counts missing packets, as detected via control word sequence number gaps. (R) |
| // (mandatory) (4-bytes) |
| // |
| // Downstream Reordered Packets Counter |
| // This attribute counts packets detected out of sequence via the control word sequence number, but |
| // successfully reordered. Some implementations may not support this feature. (R) (optional) |
| // (4-bytes) |
| // |
| // Downstream Misordered Packets Counter |
| // This attribute counts packets detected out of order via the control word sequence numbers. (R) |
| // (mandatory) (4-bytes) |
| // |
| // Upstream Timeout Packets Counter |
| // This attribute counts packets transmitted due to timeout expiration while attempting to collect |
| // cells. (R) (mandatory) (4-bytes) |
| // |
| // Upstream Transmitted Cells Counter |
| // This attribute counts transmitted cells. (R) (mandatory) (4-bytes) |
| // |
| // Upstream Dropped Cells Counter |
| // This attribute counts dropped cells. (R) (mandatory) (4-bytes) |
| // |
| // Upstream Received Cells Counter |
| // This attribute counts received cells. (R) (mandatory) (4-bytes) |
| // |
| type PwAtmPerformanceMonitoringHistoryData struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| pwatmperformancemonitoringhistorydataBME = &ManagedEntityDefinition{ |
| Name: "PwAtmPerformanceMonitoringHistoryData", |
| ClassID: 338, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| GetCurrentData, |
| ), |
| AllowedAttributeMask: 0xff80, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint32Field("DownstreamMissingPacketsCounter", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint32Field("DownstreamReorderedPacketsCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4), |
| 5: Uint32Field("DownstreamMisorderedPacketsCounter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 6: Uint32Field("UpstreamTimeoutPacketsCounter", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 7: Uint32Field("UpstreamTransmittedCellsCounter", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 8: Uint32Field("UpstreamDroppedCellsCounter", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 9: Uint32Field("UpstreamReceivedCellsCounter", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 1: "Downstream missing packets", |
| 2: "Downstream reordered packets", |
| 3: "Downstream timeout packets", |
| 4: "Upstream dropped cells", |
| }, |
| } |
| } |
| |
| // NewPwAtmPerformanceMonitoringHistoryData (class ID 338) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewPwAtmPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*pwatmperformancemonitoringhistorydataBME, params...) |
| } |