blob: 5e18218499b8cd6b2a712751cc859dd4d6d8109e [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// PwAtmPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity PW ATM performance monitoring history data
const PwAtmPerformanceMonitoringHistoryDataClassID = ClassID(338) // 0x0152
var pwatmperformancemonitoringhistorydataBME *ManagedEntityDefinition
// PwAtmPerformanceMonitoringHistoryData (Class ID: #338 / 0x0152)
// This ME collects PM data associated with an ATM pseudowire. Instances of this ME are created and
// deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the PW ATM configuration data ME.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to the instance of the PW ATM configuration data ME. (R, setbycreate)
// (mandatory) (2-bytes)
//
// Interval End Time
// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Downstream Missing Packets Counter
// This attribute counts missing packets, as detected via control word sequence number gaps. (R)
// (mandatory) (4-bytes)
//
// Downstream Reordered Packets Counter
// This attribute counts packets detected out of sequence via the control word sequence number, but
// successfully reordered. Some implementations may not support this feature. (R) (optional)
// (4-bytes)
//
// Downstream Misordered Packets Counter
// This attribute counts packets detected out of order via the control word sequence numbers. (R)
// (mandatory) (4-bytes)
//
// Upstream Timeout Packets Counter
// This attribute counts packets transmitted due to timeout expiration while attempting to collect
// cells. (R) (mandatory) (4-bytes)
//
// Upstream Transmitted Cells Counter
// This attribute counts transmitted cells. (R) (mandatory) (4-bytes)
//
// Upstream Dropped Cells Counter
// This attribute counts dropped cells. (R) (mandatory) (4-bytes)
//
// Upstream Received Cells Counter
// This attribute counts received cells. (R) (mandatory) (4-bytes)
//
type PwAtmPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
pwatmperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "PwAtmPerformanceMonitoringHistoryData",
ClassID: 338,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xff80,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("DownstreamMissingPacketsCounter", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("DownstreamReorderedPacketsCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4),
5: Uint32Field("DownstreamMisorderedPacketsCounter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field("UpstreamTimeoutPacketsCounter", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint32Field("UpstreamTransmittedCellsCounter", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
8: Uint32Field("UpstreamDroppedCellsCounter", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
9: Uint32Field("UpstreamReceivedCellsCounter", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
1: "Downstream missing packets",
2: "Downstream reordered packets",
3: "Downstream timeout packets",
4: "Upstream dropped cells",
},
}
}
// NewPwAtmPerformanceMonitoringHistoryData (class ID 338) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewPwAtmPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*pwatmperformancemonitoringhistorydataBME, params...)
}