blob: df4499f5bfcbca3811dc965e50ff84fb82758050 [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// TwdmChannelPloamPerformanceMonitoringHistoryDataPart1ClassID is the 16-bit ID for the OMCI
// Managed entity TWDM channel PLOAM performance monitoring history data part 1
const TwdmChannelPloamPerformanceMonitoringHistoryDataPart1ClassID = ClassID(446) // 0x01be
var twdmchannelploamperformancemonitoringhistorydatapart1BME *ManagedEntityDefinition
// TwdmChannelPloamPerformanceMonitoringHistoryDataPart1 (Class ID: #446 / 0x01be)
// This ME collects certain PLOAM-related PM data associated with the slot/circuit pack, hosting
// one or more ANI-G MEs, for a specific TWDM channel. Instances of this ME are created and deleted
// by the OLT.
//
// The downstream PLOAM message counts of this ME include only the received PLOAM messages
// pertaining to the given ONU, i.e.:
//
// - unicast PLOAM messages, addressed by ONU-ID;
//
// - broadcast PLOAM messages, addressed by serial number;
//
// - broadcast PLOAM messages, addressed to all ONUs on the PON.
//
// This ME includes all PLOAM PM counters characterized as mandatory in clause 14 of [ITU-
// T-G.989.3].
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of TWDM channel ME.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to an instance of the TWDM channel ME. (R, setbycreate) (mandatory) (2-bytes)
//
// Interval End Time
// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
// that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Ploam Mic Errors
// The counter of received PLOAM messages that remain unparsable due to MIC error. (R) (mandatory)
// (4-byte)
//
// Downstream Ploam Message Count
// The counter of received broadcast and unicast PLOAM messages pertaining to the given ONU. (R)
// (mandatory) (4-byte)
//
// Ranging_Time Message Count
// The counter of received Ranging_Time PLOAM messages. (R) (mandatory) (4-byte)
//
// Protection_Control Message Count
// The counter of received Protection_Control PLOAM messages. (R) (mandatory) (4-byte)
//
// Adjust_Tx_Wavelength Message Count
// The counter of received Adjust_Tx_Wavelength PLOAM messages. (R) (mandatory) (4-byte)
//
// Adjust_Tx_Wavelength Adjustment Amplitude
// An estimator of the absolute value of the transmission wavelength adjustment. (R) (mandatory)
// (4-byte)
//
type TwdmChannelPloamPerformanceMonitoringHistoryDataPart1 struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
twdmchannelploamperformancemonitoringhistorydatapart1BME = &ManagedEntityDefinition{
Name: "TwdmChannelPloamPerformanceMonitoringHistoryDataPart1",
ClassID: 446,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xff00,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("PloamMicErrors", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("DownstreamPloamMessageCount", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field("RangingTimeMessageCount", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field("ProtectionControlMessageCount", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint32Field("AdjustTxWavelengthMessageCount", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
8: Uint32Field("AdjustTxWavelengthAdjustmentAmplitude", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "PLOAM MIC errors",
},
}
}
// NewTwdmChannelPloamPerformanceMonitoringHistoryDataPart1 (class ID 446) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewTwdmChannelPloamPerformanceMonitoringHistoryDataPart1(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*twdmchannelploamperformancemonitoringhistorydatapart1BME, params...)
}