| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // PhysicalPathTerminationPointCesUniClassID is the 16-bit ID for the OMCI |
| // Managed entity Physical path termination point CES UNI |
| const PhysicalPathTerminationPointCesUniClassID ClassID = ClassID(12) |
| |
| var physicalpathterminationpointcesuniBME *ManagedEntityDefinition |
| |
| // PhysicalPathTerminationPointCesUni (class ID #12) |
| // This ME represents the point at a CES UNI in the ONU where the physical path terminates and |
| // physical level functions are performed. |
| // |
| // The ONU automatically creates an instance of this ME per port: |
| // |
| // o when the ONU has CES ports built into its factory configuration; |
| // |
| // o when a cardholder is provisioned to expect a circuit pack of a CES type; |
| // |
| // o when a cardholder provisioned for plug-and-play is equipped with a circuit pack of a CES type. |
| // Note that the installation of a plug-and-play card may indicate the presence of CES ports via |
| // equipment ID as well as its type and indeed may cause the ONU to instantiate a port-mapping |
| // package that specifies CES ports. |
| // |
| // The ONU automatically deletes instances of this ME when a cardholder is neither provisioned to |
| // expect a CES circuit pack, nor is it equipped with a CES circuit pack. |
| // |
| // Relationships |
| // An instance of this ME is associated with each real or pre-provisioned CES port. It can be |
| // linked from a GEM IW TP, a pseudowire TP or a logical N * 64 kbit/s CTP. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. This 2 byte |
| // number indicates the physical position of the UNI. The first byte is the slot ID (defined in |
| // clause 9.1.5). The second byte is the port ID, with the range 1..255. (R) (mandatory) (2-bytes) |
| // |
| // Expected Type |
| // Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory) (1-byte) |
| // |
| // Sensed Type |
| // Sensed type: If the value of expected type is not 0, then the value of sensed type equals the |
| // value of expected type. If expected type-= 0, then the value of sensed type is one of the |
| // compatible values from Table-9.1.5-1. Upon ME instantiation, the ONU sets this attribute to 0 or |
| // to the value that reflects the physically present equipment. (R) (mandatory if the ONU supports |
| // circuit packs with configurable interface types, e.g., C1.5/2/6.3) (1-byte) |
| // |
| // Ces Loopback Configuration |
| // Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory) (1-byte) |
| // |
| // Administrative State |
| // Administrative state: This attribute locks (1) and unlocks (0) the functions performed by this |
| // ME. Administrative state is further described in clause A.1.6. (R,-W) (mandatory) (1-byte) |
| // |
| // Operational State |
| // Operational state: This attribute indicates whether the ME is capable of performing its |
| // function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte) |
| // |
| // Framing |
| // Upon ME instantiation, the ONU sets this attribute to a value that reflects the vendor's |
| // default. (R,-W) (optional) (1-byte) |
| // |
| // Encoding |
| // Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory for DS1 and DS3 |
| // interfaces) (1-byte) |
| // |
| // Line Length |
| // Line length: This attribute specifies the length of the twisted pair cable from a DS1 physical |
| // UNI to the DSX-1 cross-connect point or the length of coaxial cable from a DS3 physical UNI to |
| // the DSX-3 cross-connect point. Valid values are given in Table 9.8.1-1. Upon ME instantiation |
| // for a DS1 interface, the ONU assigns the value 0 for non-power feed type DS1 and the value 6 for |
| // power feed type DS1. Upon ME instantiation for a DS3 interface, the ONU sets this attribute to |
| // 0x0F. (R,-W) (optional) (1-byte) |
| // |
| // Ds1 Mode |
| // In the event of conflicting values between this attribute and the (also optional) line length |
| // attribute, the line length attribute is taken to be valid. This permits the separation of line |
| // build-out (LBO) and power settings from smart jack and FDL behaviour. Upon ME instantiation, the |
| // ONU sets this attribute to 0. (R,-W) (optional) (1-byte) |
| // |
| // Arc |
| // ARC: See clause A.1.4.3. (R,-W) (optional) (1-byte) |
| // |
| // Arc Interval |
| // ARC interval: See clause A.1.4.3. (R,-W) (optional) (1-byte) |
| // |
| // Line Type |
| // (R,-W) (mandatory for DS3, E3 and multi-configuration interfaces, not applicable to other |
| // interfaces) (1-byte) |
| // |
| type PhysicalPathTerminationPointCesUni struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| physicalpathterminationpointcesuniBME = &ManagedEntityDefinition{ |
| Name: "PhysicalPathTerminationPointCesUni", |
| ClassID: 12, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xfff0, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: ByteField("ExpectedType", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1), |
| 2: ByteField("SensedType", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), true, false, false, 2), |
| 3: ByteField("CesLoopbackConfiguration", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), true, false, false, 3), |
| 4: ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, false, false, 4), |
| 5: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), true, true, false, 5), |
| 6: ByteField("Framing", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6), |
| 7: ByteField("Encoding", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, false, false, 7), |
| 8: ByteField("LineLength", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8), |
| 9: ByteField("Ds1Mode", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, Write), false, true, false, 9), |
| 10: ByteField("Arc", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), true, true, false, 10), |
| 11: ByteField("ArcInterval", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, Write), false, true, false, 11), |
| 12: ByteField("LineType", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, Write), false, false, false, 12), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 0: "TF", |
| 1: "LOS", |
| 2: "LOF", |
| 3: "OOF", |
| 4: "RAI", |
| 5: "1.5 M BAIS", |
| 6: "R-INH", |
| 7: "6M REC", |
| 8: "6M SEND", |
| 9: "6M ERR", |
| 10: "6M BERR", |
| 11: "34M REC", |
| 12: "34M AIS", |
| 13: "2M REC", |
| 14: "2M AIS", |
| 15: "1.5M REC", |
| 16: "1.5 AIS", |
| 17: "INFO0", |
| 18: "45M RDI", |
| 19: "45M AIS", |
| 20: "AIS-CI", |
| 21: "DS1 idle", |
| 22: "RAI-CI", |
| }, |
| } |
| } |
| |
| // NewPhysicalPathTerminationPointCesUni (class ID 12) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewPhysicalPathTerminationPointCesUni(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*physicalpathterminationpointcesuniBME, params...) |
| } |