blob: cc66a165c35334d42bee68220c5736eb6e8600ae [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// PhysicalPathTerminationPointCesUniClassID is the 16-bit ID for the OMCI
// Managed entity Physical path termination point CES UNI
const PhysicalPathTerminationPointCesUniClassID ClassID = ClassID(12)
var physicalpathterminationpointcesuniBME *ManagedEntityDefinition
// PhysicalPathTerminationPointCesUni (class ID #12)
// This ME represents the point at a CES UNI in the ONU where the physical path terminates and
// physical level functions are performed.
//
// The ONU automatically creates an instance of this ME per port:
//
// o when the ONU has CES ports built into its factory configuration;
//
// o when a cardholder is provisioned to expect a circuit pack of a CES type;
//
// o when a cardholder provisioned for plug-and-play is equipped with a circuit pack of a CES type.
// Note that the installation of a plug-and-play card may indicate the presence of CES ports via
// equipment ID as well as its type and indeed may cause the ONU to instantiate a port-mapping
// package that specifies CES ports.
//
// The ONU automatically deletes instances of this ME when a cardholder is neither provisioned to
// expect a CES circuit pack, nor is it equipped with a CES circuit pack.
//
// Relationships
// An instance of this ME is associated with each real or pre-provisioned CES port. It can be
// linked from a GEM IW TP, a pseudowire TP or a logical N * 64 kbit/s CTP.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. This 2 byte
// number indicates the physical position of the UNI. The first byte is the slot ID (defined in
// clause 9.1.5). The second byte is the port ID, with the range 1..255. (R) (mandatory) (2-bytes)
//
// Expected Type
// Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory) (1-byte)
//
// Sensed Type
// Sensed type: If the value of expected type is not 0, then the value of sensed type equals the
// value of expected type. If expected type-= 0, then the value of sensed type is one of the
// compatible values from Table-9.1.5-1. Upon ME instantiation, the ONU sets this attribute to 0 or
// to the value that reflects the physically present equipment. (R) (mandatory if the ONU supports
// circuit packs with configurable interface types, e.g., C1.5/2/6.3) (1-byte)
//
// Ces Loopback Configuration
// Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory) (1-byte)
//
// Administrative State
// Administrative state: This attribute locks (1) and unlocks (0) the functions performed by this
// ME. Administrative state is further described in clause A.1.6. (R,-W) (mandatory) (1-byte)
//
// Operational State
// Operational state: This attribute indicates whether the ME is capable of performing its
// function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte)
//
// Framing
// Upon ME instantiation, the ONU sets this attribute to a value that reflects the vendor's
// default. (R,-W) (optional) (1-byte)
//
// Encoding
// Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory for DS1 and DS3
// interfaces) (1-byte)
//
// Line Length
// Line length: This attribute specifies the length of the twisted pair cable from a DS1 physical
// UNI to the DSX-1 cross-connect point or the length of coaxial cable from a DS3 physical UNI to
// the DSX-3 cross-connect point. Valid values are given in Table 9.8.1-1. Upon ME instantiation
// for a DS1 interface, the ONU assigns the value 0 for non-power feed type DS1 and the value 6 for
// power feed type DS1. Upon ME instantiation for a DS3 interface, the ONU sets this attribute to
// 0x0F. (R,-W) (optional) (1-byte)
//
// Ds1 Mode
// In the event of conflicting values between this attribute and the (also optional) line length
// attribute, the line length attribute is taken to be valid. This permits the separation of line
// build-out (LBO) and power settings from smart jack and FDL behaviour. Upon ME instantiation, the
// ONU sets this attribute to 0. (R,-W) (optional) (1-byte)
//
// Arc
// ARC: See clause A.1.4.3. (R,-W) (optional) (1-byte)
//
// Arc Interval
// ARC interval: See clause A.1.4.3. (R,-W) (optional) (1-byte)
//
// Line Type
// (R,-W) (mandatory for DS3, E3 and multi-configuration interfaces, not applicable to other
// interfaces) (1-byte)
//
type PhysicalPathTerminationPointCesUni struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
physicalpathterminationpointcesuniBME = &ManagedEntityDefinition{
Name: "PhysicalPathTerminationPointCesUni",
ClassID: 12,
MessageTypes: mapset.NewSetWith(
Get,
Set,
),
AllowedAttributeMask: 0xfff0,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0),
1: ByteField("ExpectedType", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1),
2: ByteField("SensedType", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), true, false, false, 2),
3: ByteField("CesLoopbackConfiguration", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), true, false, false, 3),
4: ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, false, false, 4),
5: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), true, true, false, 5),
6: ByteField("Framing", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6),
7: ByteField("Encoding", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, false, false, 7),
8: ByteField("LineLength", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8),
9: ByteField("Ds1Mode", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, Write), false, true, false, 9),
10: ByteField("Arc", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), true, true, false, 10),
11: ByteField("ArcInterval", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, Write), false, true, false, 11),
12: ByteField("LineType", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, Write), false, false, false, 12),
},
Access: CreatedByOnu,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "TF",
1: "LOS",
2: "LOF",
3: "OOF",
4: "RAI",
5: "1.5 M BAIS",
6: "R-INH",
7: "6M REC",
8: "6M SEND",
9: "6M ERR",
10: "6M BERR",
11: "34M REC",
12: "34M AIS",
13: "2M REC",
14: "2M AIS",
15: "1.5M REC",
16: "1.5 AIS",
17: "INFO0",
18: "45M RDI",
19: "45M AIS",
20: "AIS-CI",
21: "DS1 idle",
22: "RAI-CI",
},
}
}
// NewPhysicalPathTerminationPointCesUni (class ID 12) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewPhysicalPathTerminationPointCesUni(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*physicalpathterminationpointcesuniBME, params...)
}