| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // EthernetPerformanceMonitoringHistoryData3ClassID is the 16-bit ID for the OMCI |
| // Managed entity Ethernet performance monitoring history data 3 |
| const EthernetPerformanceMonitoringHistoryData3ClassID ClassID = ClassID(296) |
| |
| var ethernetperformancemonitoringhistorydata3BME *ManagedEntityDefinition |
| |
| // EthernetPerformanceMonitoringHistoryData3 (class ID #296) |
| // This ME collects PM data associated with an Ethernet interface. It includes parameters defined |
| // in the Ethernet statistics group of [IETF RFC 2819] that are not already covered by previously |
| // defined Ethernet monitoring MEs. The received direction is from the CPE towards the network |
| // (upstream). |
| // |
| // NOTE 1 - Several of the same counters are available from the Ethernet frame PM history data MEs, |
| // which are associated with MAC bridge ports. MAC bridge port association allows those MEs to be |
| // used for any Ethernet flow, in both upstream and downstream directions, while the Ethernet PM |
| // history data 3 ME can only be used on a physical IEEE 802.3 port. |
| // |
| // Instances of this ME are created and deleted by the OLT. |
| // |
| // For a complete discussion of generic PM architecture, refer to clause I.4. |
| // |
| // NOTE 2 - Implementers are encouraged to consider the Ethernet frame extended PM ME defined in |
| // clause-9.3.32, which collects the same counters in a more generalized way. |
| // |
| // Relationships |
| // An instance of this ME is associated with an instance of the PPTP Ethernet UNI. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| // identical ID, this ME is implicitly linked to an instance of the PPTP Ethernet UNI. (R, |
| // setbycreate) (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| // (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Drop Events |
| // Drop events: The total number of events in which packets were dropped due to a lack of |
| // resources. This is not necessarily the number of packets dropped; it is the number of times this |
| // event was detected. (R) (mandatory) (4-bytes) |
| // |
| // Octets |
| // Octets: The total number of octets received from the CPE, including those in bad packets, |
| // excluding framing bytes, but including FCS. (R) (mandatory) (4-bytes) |
| // |
| // Packets |
| // Packets: The total number of packets received, including bad packets, broadcast packets and |
| // multicast packets. (R) (mandatory) (4-bytes) |
| // |
| // Broadcast Packets |
| // Broadcast packets: The total number of received good packets directed to the broadcast address. |
| // This does not include multicast packets. (R) (mandatory) (4-bytes) |
| // |
| // Multicast Packets |
| // Multicast packets: The total number of received good packets directed to a multicast address. |
| // This does not include broadcast packets. (R) (mandatory) (4-bytes) |
| // |
| // Undersize Packets |
| // Undersize packets: The total number of packets received that were less than 64 octets long, but |
| // were otherwise well formed (excluding framing bits, but including FCS). (R) (mandatory) |
| // (4-bytes) |
| // |
| // Fragments |
| // Fragments: The total number of packets received that were less than 64 octets long, excluding |
| // framing bits but including FCS octets, and had either a bad FCS with an integral number of |
| // octets (FCS error) or a bad FCS with a non-integral number of octets (alignment error). It is |
| // entirely normal for this attribute to increment. This is because it counts both runts (which are |
| // normal occurrences due to collisions) and noise hits. (R) (mandatory) (4-bytes) |
| // |
| // Jabbers |
| // Jabbers: The total number of packets received that were longer than 1518 octets, excluding |
| // framing bits but including FCS octets, and had either a bad FCS with an integral number of |
| // octets (FCS error) or a bad FCS with a non-integral number of octets (alignment error). The |
| // range to detect jabber is between 20 ms and 150 ms. (R) (mandatory) (4-bytes) |
| // |
| // Packets 64 Octets |
| // Packets 64 octets: The total number of received packets (including bad packets) that were |
| // 64-octets long, excluding framing bits but including FCS. (R) (mandatory) (4-bytes) |
| // |
| // Packets 65 To 127 Octets |
| // Packets 65 to 127 octets: The total number of received packets (including bad packets) that were |
| // 65..127 octets long, excluding framing bits but including FCS. (R) (mandatory) (4-bytes) |
| // |
| // Packets 128 To 255 Octets |
| // Packets 128 to 255 octets: The total number of packets (including bad packets) received that |
| // were 128..255 octets long, excluding framing bits but including FCS. (R) (mandatory) (4-bytes) |
| // |
| // Packets 256 To 511 Octets |
| // Packets 256 to 511 octets: The total number of packets (including bad packets) received that |
| // were 256..511 octets long, excluding framing bits but including FCS. (R) (mandatory) (4-bytes) |
| // |
| // Packets 512 To 1023 Octets |
| // Packets 512 to 1023 octets: The total number of packets (including bad packets) received that |
| // were 512..1023 octets long, excluding framing bits but including FCS. (R) (mandatory) (4-bytes) |
| // |
| // Packets 1024 To 1518 Octets |
| // Packets 1024 to 1518 octets: The total number of packets (including bad packets) received that |
| // were 1024..1518 octets long, excluding framing bits but including FCS. (R) (mandatory) (4-bytes) |
| // |
| type EthernetPerformanceMonitoringHistoryData3 struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| ethernetperformancemonitoringhistorydata3BME = &ManagedEntityDefinition{ |
| Name: "EthernetPerformanceMonitoringHistoryData3", |
| ClassID: 296, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xffff, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", PointerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint32Field("DropEvents", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint32Field("Octets", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 5: Uint32Field("Packets", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 6: Uint32Field("BroadcastPackets", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 7: Uint32Field("MulticastPackets", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 8: Uint32Field("UndersizePackets", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 9: Uint32Field("Fragments", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9), |
| 10: Uint32Field("Jabbers", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10), |
| 11: Uint32Field("Packets64Octets", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11), |
| 12: Uint32Field("Packets65To127Octets", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12), |
| 13: Uint32Field("Packets128To255Octets", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, false, false, 13), |
| 14: Uint32Field("Packets256To511Octets", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, false, false, 14), |
| 15: Uint32Field("Packets512To1023Octets", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, false, false, 15), |
| 16: Uint32Field("Packets1024To1518Octets", CounterAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, false, false, 16), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewEthernetPerformanceMonitoringHistoryData3 (class ID 296) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewEthernetPerformanceMonitoringHistoryData3(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*ethernetperformancemonitoringhistorydata3BME, params...) |
| } |