blob: 9fb48910ee58712d35066f5013d15a3b4d460dda [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// RtpPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity RTP performance monitoring history data
const RtpPerformanceMonitoringHistoryDataClassID ClassID = ClassID(144)
var rtpperformancemonitoringhistorydataBME *ManagedEntityDefinition
// RtpPerformanceMonitoringHistoryData (class ID #144)
// This ME collects PM data related to an RTP session. Instances of this ME are created and deleted
// by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the PPTP POTS UNI ME.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an
// identical ID, this ME is implicitly linked to an instance of the PPTP POTS UNI ME. (R,
// setbycreate) (mandatory) (2-bytes)
//
// Interval End Time
// Interval end time: This attribute identifies the most recently finished 15-min interval. (R)
// (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Rtp Errors
// RTP errors: This attribute counts RTP packet errors. (R) (mandatory) (4-bytes)
//
// Packet Loss
// Packet loss: This attribute represents the fraction of packets lost. This attribute is
// calculated at the end of the 15-min interval, and is undefined under the get current data
// action. The value 0 indicates no packet loss, scaling linearly to 0xFFFF FFFF to indicate 100%
// packet loss (zero divided by zero is defined to be zero). (R) (mandatory) (4-bytes)
//
// Maximum Jitter
// Maximum jitter: This attribute is a high water-mark that represents the maximum jitter
// identified during the measured interval, expressed in RTP timestamp units. (R) (mandatory)
// (4-bytes)
//
// Maximum Time Between Real_Time Transport Control Protocol Rtcp Packets
// Maximum time between real-time transport control protocol (RTCP) packets: This attribute is a
// high water-mark that represents the maximum time between RTCP packets during the measured
// interval, in milliseconds. (R) (mandatory) (4-bytes)
//
// Buffer Underflows
// Buffer underflows: This attribute counts the number of times the reassembly buffer underflows.
// In the case of continuous underflow caused by a loss of IP packets, a single buffer underflow
// should be counted. If the IW function is implemented with multiple buffers, such as a packet
// level buffer and a bit level buffer, then the underflow of either buffer increments this
// counter. (R) (mandatory) (4-bytes)
//
// Buffer Overflows
// Buffer overflows: This attribute counts the number of times the reassembly buffer overflows. If
// the IW function is implemented with multiple buffers, such as a packet level buffer and a bit
// level buffer, then the overflow of either buffer increments this counter. (R) (mandatory)
// (4-bytes)
//
type RtpPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
rtpperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "RtpPerformanceMonitoringHistoryData",
ClassID: 144,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
),
AllowedAttributeMask: 0xff00,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("RtpErrors", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("PacketLoss", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field("MaximumJitter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field("MaximumTimeBetweenRealTimeTransportControlProtocolRtcpPackets", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint32Field("BufferUnderflows", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
8: Uint32Field("BufferOverflows", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
},
Access: CreatedByOlt,
Support: UnknownSupport,
}
}
// NewRtpPerformanceMonitoringHistoryData (class ID 144) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewRtpPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*rtpperformancemonitoringhistorydataBME, params...)
}