| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // XdslLineConfigurationProfilePart2ClassID is the 16-bit ID for the OMCI |
| // Managed entity xDSL line configuration profile part 2 |
| const XdslLineConfigurationProfilePart2ClassID ClassID = ClassID(105) |
| |
| var xdsllineconfigurationprofilepart2BME *ManagedEntityDefinition |
| |
| // XdslLineConfigurationProfilePart2 (class ID #105) |
| // The overall xDSL line configuration profile is modelled in several parts, all of which are |
| // associated together through a common ME ID (the client PPTP xDSL UNI part 1 has a single |
| // pointer, which refers to the entire set of line configuration profile parts). |
| // |
| // Relationships |
| // An instance of this ME may be associated with zero or more instances of an xDSL UNI. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. All xDSL and |
| // VDSL2 line configuration profiles and extensions that pertain to a given PPTP xDSL UNI must |
| // share a common ME ID. (R, setbycreate) (mandatory) (2-bytes) |
| // |
| // Downstream Minimum Time Interval For Upshift Rate Adaptation |
| // Downstream minimum time interval for upshift rate adaptation: This parameter defines the |
| // interval during which the downstream noise margin must remain above the downstream upshift noise |
| // margin before the xTU-R attempts to increase the downstream net data rate. Its value ranges from |
| // 0 to 16383-s. (R,-W, setbycreate) (optional) (2-bytes) |
| // |
| // Upstream Minimum Time Interval For Upshift Rate Adaptation |
| // Upstream minimum time interval for upshift rate adaptation: This parameter defines the interval |
| // during which the upstream noise margin must remain above the upstream upshift noise margin |
| // before the xTU-C attempts to increase the upstream net data rate. Its value ranges from 0 to |
| // 16383-s. (R,-W, setbycreate) (optional) (2-bytes) |
| // |
| // Downstream Downshift Noise Margin |
| // Downstream downshift noise margin: If the downstream noise margin is below the downstream |
| // downshift noise margin and remains there for more than the downstream minimum time interval for |
| // downshift rate adaptation, the xTU-R attempts to decrease the downstream net data rate. This |
| // attribute's value ranges from 0 (0.0 dB) to 310 (31.0 dB). (R,-W, setbycreate) (optional) |
| // (2-bytes) |
| // |
| // Upstream Downshift Noise Margin |
| // Upstream downshift noise margin: If the upstream noise margin is below the upstream downshift |
| // noise margin and remains there for more than the upstream minimum time interval for downshift |
| // rate adaptation, the xTUC attempts to decrease the upstream net data rate. This attribute's |
| // value ranges from 0 (0.0 dB) to 310 (31.0 dB). (R,-W, setbycreate) (optional) (2-bytes) |
| // |
| // Downstream Minimum Time Interval For Downshift Rate Adaptation |
| // Downstream minimum time interval for downshift rate adaptation: This parameter defines the |
| // interval during which the downstream noise margin must remain below the downstream downshift |
| // noise margin before the xTU-R attempts to decrease the downstream net data rate. Its value |
| // ranges from 0 to 16383-s. (R,-W, setbycreate) (optional) (2-bytes) |
| // |
| // Upstream Minimum Time Interval For Downshift Rate Adaptation |
| // Upstream minimum time interval for downshift rate adaptation: This parameter defines the |
| // interval during which the upstream noise margin must remain below the upstream downshift noise |
| // margin before the xTU-C attempts to decrease the upstream net data rate. Its value ranges from 0 |
| // to 16383-s. (R,-W, setbycreate) (optional) (2-bytes) |
| // |
| // Xtu Impedance State Forced |
| // (R,-W, setbycreate) (optional) (1-byte) |
| // |
| // L0_Time |
| // L0-time: This parameter specifies the minimum time between an exit from the L2 state and the |
| // next entry into the L2 state. It is only valid for [ITUT-G.992.3], [ITUT-G.992.4] and |
| // [ITUT-G.992.5]. It ranges from 0 to 255-s. (R,-W, setbycreate) (mandatory) (1 byte) |
| // |
| // L2_Time |
| // L2-time: This parameter specifies the minimum time between an entry into the L2 state and the |
| // first power trim in the L2 state, or between two consecutive power trims in the L2 state. It is |
| // only valid for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. It ranges from 0 to 255-s. (R, |
| // W, setbycreate) (mandatory) (1 byte) |
| // |
| // Downstream Maximum Nominal Power Spectral Density |
| // Downstream maximum nominal power spectral density: This attribute specifies the maximum nominal |
| // transmit PSD in the downstream direction during initialization and showtime. A single |
| // MAXNOMPSDds attribute is defined per mode enabled in the xTSE line configuration attribute. It |
| // is only valid for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. Its value ranges from 0 |
| // (60.0-dBm/Hz) to 300 (-30-dBm/Hz). (R, W, setbycreate) (mandatory) (2 bytes) |
| // |
| // Upstream Maximum Nominal Power Spectral Density |
| // Upstream maximum nominal power spectral density: This attribute specifies the maximum nominal |
| // transmit PSD in the upstream direction during initialization and showtime. A single MAXNOMPSDus |
| // attribute is defined per mode enabled in the xTSE line configuration attribute. It is only valid |
| // for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.993.2]. Its value ranges from 0 (-60.0-dBm/Hz) to |
| // 300 (-30-dBm/Hz). (R, W, setbycreate) (mandatory) (2 bytes) |
| // |
| // Downstream Maximum Nominal Aggregate Transmit Power |
| // Downstream maximum nominal aggregate transmit power: This attribute specifies the maximum |
| // nominal aggregate transmit power in the downstream direction during initialization and showtime. |
| // It is only valid for [ITUT-G.992.3], [ITUT-G.992.4], [ITUT-G.992.5] and [ITUT-G.993.2]. Its |
| // value ranges from 0 (0.0-dBm) to 255 (25.5-dBm). (R, W, setbycreate) (mandatory) (1-byte) |
| // |
| // Upstream Maximum Nominal Aggregate Transmit Power |
| // Upstream maximum nominal aggregate transmit power: This parameter specifies the maximum nominal |
| // aggregate transmit power in the upstream direction during initialization and showtime. It is |
| // only valid for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. Its value ranges from 0 |
| // (0.0-dBm) to 255 (25.5-dBm). (R, W, setbycreate) (mandatory) (1 byte) |
| // |
| // Upstream Maximum Aggregate_Receive Power |
| // Upstream maximum aggregate-receive power: This parameter specifies the maximum upstream |
| // aggregate receive power over a set of subcarriers, as defined in the relevant Recommendation. |
| // The xTU-C requests an upstream power cutback such that the upstream aggregate receive power over |
| // that set of subcarriers is at or below the configured maximum value. It is only valid for |
| // [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. This attribute ranges from 0 (25.5-dBm) to |
| // 510 (+25.5-dBm). The special value 0xFFFF indicates that no upstream maximum aggregate receive |
| // power limit is to be applied. (R, W setbycreate) (mandatory) (2 bytes) |
| // |
| // Vdsl2 Transmission System Enabling |
| // VDSL2 transmission system enabling: This configuration attribute extends the transmission system |
| // coding types to be allowed by the xTU-C. It is a bit map, defined as octet 8 (bits 57..64) in |
| // Table-9.7.12-1. (R, W, setbycreate) (optional) (1 byte) |
| // |
| type XdslLineConfigurationProfilePart2 struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| xdsllineconfigurationprofilepart2BME = &ManagedEntityDefinition{ |
| Name: "XdslLineConfigurationProfilePart2", |
| ClassID: 105, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xfffe, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: Uint16Field("DownstreamMinimumTimeIntervalForUpshiftRateAdaptation", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 1), |
| 2: Uint16Field("UpstreamMinimumTimeIntervalForUpshiftRateAdaptation", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 2), |
| 3: Uint16Field("DownstreamDownshiftNoiseMargin", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 3), |
| 4: Uint16Field("UpstreamDownshiftNoiseMargin", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 4), |
| 5: Uint16Field("DownstreamMinimumTimeIntervalForDownshiftRateAdaptation", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 5), |
| 6: Uint16Field("UpstreamMinimumTimeIntervalForDownshiftRateAdaptation", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 6), |
| 7: ByteField("XtuImpedanceStateForced", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 7), |
| 8: ByteField("L0Time", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 8), |
| 9: ByteField("L2Time", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 9), |
| 10: Uint16Field("DownstreamMaximumNominalPowerSpectralDensity", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 10), |
| 11: Uint16Field("UpstreamMaximumNominalPowerSpectralDensity", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 11), |
| 12: ByteField("DownstreamMaximumNominalAggregateTransmitPower", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 12), |
| 13: ByteField("UpstreamMaximumNominalAggregateTransmitPower", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 13), |
| 14: Uint16Field("UpstreamMaximumAggregateReceivePower", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, false, false, 14), |
| 15: ByteField("Vdsl2TransmissionSystemEnabling", UnsignedIntegerAttributeType, 0x0002, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 15), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewXdslLineConfigurationProfilePart2 (class ID 105) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewXdslLineConfigurationProfilePart2(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*xdsllineconfigurationprofilepart2BME, params...) |
| } |