blob: 082de7430d7b8ad350a869f4af97d489daf23277 [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// MgcPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity MGC performance monitoring history data
const MgcPerformanceMonitoringHistoryDataClassID = ClassID(156) // 0x009c
var mgcperformancemonitoringhistorydataBME *ManagedEntityDefinition
// MgcPerformanceMonitoringHistoryData (Class ID: #156 / 0x009c)
// The MGC monitoring data ME provides run-time statistics for an active MGC association. Instances
// of this ME are created and deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the MGC config data or MGC config
// portal ME.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to an instance of the associated MGC config data or to the MGC config portal
// ME. If a non-OMCI configuration method is used for VoIP, there can be only one live ME instance,
// associated with the MGC config portal, and with ME ID 0. (R, setbycreate) (mandatory) (2-bytes)
//
// Interval End Time
// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Received Messages
// This attribute counts the number of received Megaco messages on this association, as defined by
// [ITUT H.341]. (R) (mandatory) (4-bytes)
//
// Received Octets
// This attribute counts the total number of octets received on this association, as defined by
// [ITU-T H.341]. (R) (mandatory) (4-bytes)
//
// Sent Messages
// This attribute counts the total number of Megaco messages sent over this association, as defined
// by [ITU-T H.341]. (R) (mandatory) (4-bytes)
//
// Sent Octets
// This attribute counts the total number of octets sent over this association, as defined by
// [ITU-T H.341]. (R) (mandatory) (4-bytes)
//
// Protocol Errors
// This attribute counts the total number of errors detected on this association, as defined by
// [ITU-T H.341]. This includes:
//
// o syntax errors detected in a given received message;
//
// o outgoing transactions that failed for protocol reasons.
//
// (R) (mandatory) (4-bytes)
//
// Transport Losses
// This attribute counts the total number of transport losses (e.g., socket problems) detected on
// this association. A link loss is defined as loss of communication with the remote entity due to
// hardware/transient problems, or problems in related software. (R) (mandatory) (4-bytes)
//
// Last Detected Event
// This attribute reports the last event detected on this association. This includes events such as
// the link failing or being set up. Under normal circumstances, a get action on this attribute
// would return 0 to indicate no abnormal activity. This field is an enumeration as follows.
//
// 0 No event - No event has yet been detected during this PM interval.
//
// 1 Link up - The transport link underpinning the association came up.
//
// 2 Link down - The transport link underpinning the association went down.
//
// 3 Persistent error - A persistent error was detected on the link (such as the socket/TCP
// connection to the remote node could not be set up).
//
// 4 Local shutdown - The association was brought down intentionally by the local application.
//
// 5 Failover down - The association was brought down as part of failover processing.
//
// 255 Other event - The latest event does not match any in the list.
//
// (R) (mandatory) (1-byte)
//
// Last Detected Event Time
// This attribute reports the time in seconds since the last event on this association was
// detected, as defined by [ITU-T H.341]. (R) (mandatory) (4-bytes)
//
// Last Detected Reset Time
// This attribute reports the time in seconds since these statistics were last reset, as defined by
// [ITU-T H.341]. Under normal circumstances, a get action on this attribute would return 900-s to
// indicate a completed 15-min interval. (R) (mandatory) (4-bytes)
//
type MgcPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
mgcperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "MgcPerformanceMonitoringHistoryData",
ClassID: 156,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xffe0,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("ReceivedMessages", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("ReceivedOctets", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field("SentMessages", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field("SentOctets", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint32Field("ProtocolErrors", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
8: Uint32Field("TransportLosses", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
9: ByteField("LastDetectedEvent", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9),
10: Uint32Field("LastDetectedEventTime", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10),
11: Uint32Field("LastDetectedResetTime", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "MGCP protocol errors",
1: "MGCP transport losses",
},
}
}
// NewMgcPerformanceMonitoringHistoryData (class ID 156) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewMgcPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {