| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // TimeStatusMessageClassID is the 16-bit ID for the OMCI |
| // Managed entity Time Status Message |
| const TimeStatusMessageClassID = ClassID(440) // 0x01b8 |
| |
| var timestatusmessageBME *ManagedEntityDefinition |
| |
| // TimeStatusMessage (Class ID: #440 / 0x01b8) |
| // This ME provides status and characterization information for the time-transmitting node and its |
| // grandmaster. An ONU that supports time synchronization automatically creates an instance of this |
| // ME. The best practise is to set all the attributes at the same time. |
| // |
| // Relationships |
| // The single instance of this ME is associated with the ONU ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. There is only one instance, number |
| // 0. (R) (mandatory) (2 bytes) |
| // |
| // Domain Number |
| // Using the format of clause 7.1 of [IEEE 1588]. The default value is 0. (R, W) (mandatory) (1 |
| // byte) |
| // |
| // Flag Field |
| // The field format is given in the table. Value 1 represents "true". (R, W) (mandatory) (1 byte) |
| // |
| // Currentutcoffset |
| // Provides the UTC offset value between the TAI and UTC timescales (UTC Offset-= TAI-- UTC), as |
| // specified in clause 7.2.3 of [IEEE 1588]. (R, W) (mandatory) (2 bytes) |
| // |
| // Priority1 |
| // As specified in clause 7.6.2.2 of [IEEE 1588]. (R, W) (mandatory) (1 byte) |
| // |
| // Clockclass |
| // Provides the clockClass information denoting the traceability of the time distributed by the |
| // grandmaster clock, as specified in clause 7.6.2.4 of [IEEE 1588]. (R, W) (mandatory) (1 byte) |
| // |
| // Accuracy |
| // Indicates the expected accuracy of a clock when it is the grandmaster, as specified in clause |
| // 7.6.2.5 of [IEEE 1588]. (R, W) (mandatory) (1 byte) |
| // |
| // Offsetscaledlogvariance |
| // Provides the estimate of the time variance, as specified in clause-7.6.3 of [IEEE 1588]. (R, W) |
| // (mandatory) (2 bytes) |
| // |
| // Priority2 |
| // As specified in clause 7.6.2.3 of [IEEE 1588]. (R, W) (mandatory) (1 byte) |
| // |
| // Grandmaster ID: The clockIdentity attribute of the grandmaster, taken from the IEEE EUI64 |
| // individual assigned numbers. (R, W) (mandatory) (8 bytes) |
| // |
| // Steps removed: Provides the number of boundary clocks between the local clock and the master. |
| // (R, W) (mandatory) (2 bytes) |
| // |
| // Time source: Indicates the source of time used by the grandmaster clock, as specified in clause |
| // 7.6.2.6 of [IEEE 1588]. (R, W) (mandatory) (1 byte) |
| // |
| type TimeStatusMessage struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| timestatusmessageBME = &ManagedEntityDefinition{ |
| Name: "TimeStatusMessage", |
| ClassID: 440, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xff00, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: ByteField("DomainNumber", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1), |
| 2: ByteField("FlagField", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, false, false, 2), |
| 3: Uint16Field("Currentutcoffset", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, false, false, 3), |
| 4: ByteField("Priority1", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, false, false, 4), |
| 5: ByteField("Clockclass", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5), |
| 6: ByteField("Accuracy", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, false, false, 6), |
| 7: Uint16Field("Offsetscaledlogvariance", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, false, false, 7), |
| 8: ByteField("Priority2", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, false, false, 8), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 0: "Clock unlock", |
| 1: "ESMC loss", |
| 2: "Time unlock", |
| }, |
| } |
| } |
| |
| // NewTimeStatusMessage (class ID 440) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewTimeStatusMessage(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*timestatusmessageBME, params...) |
| } |