| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // ReAniGClassID is the 16-bit ID for the OMCI |
| // Managed entity RE ANI-G |
| const ReAniGClassID ClassID = ClassID(313) |
| |
| var reanigBME *ManagedEntityDefinition |
| |
| // ReAniG (class ID #313) |
| // This ME organizes data associated with each R'/S' physical interface of an RE if the RE supports |
| // OEO regeneration in either direction. The management ONU automatically creates one instance of |
| // this ME for each R'/S' physical port (uni- or bidirectional) as follows. |
| // |
| // o When the RE has mid-span PON RE ANI interface ports built into its factory configuration. |
| // |
| // o When a cardholder is provisioned to expect a circuit pack of the mid-span PON RE ANI type. |
| // |
| // o When a cardholder provisioned for plug-and-play is equipped with a circuit pack of the midspan |
| // PON RE ANI type. Note that the installation of a plug-and-play card may indicate the presence of |
| // a mid-span PON RE ANI port via equipment ID as well as its type attribute, and indeed may cause |
| // the management ONU to instantiate a port-mapping package to specify the ports precisely. |
| // |
| // The management ONU automatically deletes instances of this ME when a cardholder is neither |
| // provisioned to expect a mid-span PON RE ANI circuit pack, nor is it equipped with a mid-span PON |
| // RE ANI circuit pack. |
| // |
| // As illustrated in Figure 8.2.10-4, an RE ANI-G may share the physical port with an RE downstream |
| // amplifier. The ONU declares a shared configuration through the port-mapping package combined |
| // port table, whose structure defines one ME as the master. It is recommended that the RE ANI-G be |
| // the master, with the RE downstream amplifier as a secondary ME. |
| // |
| // The administrative state, operational state and ARC attributes of the master ME override similar |
| // attributes in secondary MEs associated with the same port. In the secondary ME, these attributes |
| // are present, but cause no action when written and have undefined values when read. The RE |
| // downstream amplifier should use its provisionable downstream alarm thresholds and should declare |
| // downstream alarms as necessary; other isomorphic alarms should be declared by the RE ANI-G. The |
| // test action should be addressed to the master ME. |
| // |
| // Relationships |
| // An instance of this ME is associated with each R'/S' physical interface of an RE that includes |
| // OEO regeneration in either direction, and with one or more instances of the PPTP RE UNI. It may |
| // also be associated with an RE downstream amplifier. |
| // |
| // Attributes |
| // Managed Entity Id |
| // NOTE 1 - This ME ID may be identical to that of an RE downstream amplifier if it shares the same |
| // physical slot and port. |
| // |
| // Administrative State |
| // NOTE 2 - When an RE supports multiple PONs, or protected access to a single PON, its primary |
| // ANI-G cannot be completely shut down, due to a loss of the management communications capability. |
| // Complete blocking of service and removal of power may nevertheless be appropriate for secondary |
| // RE ANI-Gs. Administrative lock suppresses alarms and notifications for an RE ANI-G, be it either |
| // primary or secondary. |
| // |
| // Operational State |
| // Operational state: This attribute indicates whether the ME is capable of performing its |
| // function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte) |
| // |
| // Arc |
| // ARC: See clause A.1.4.3. (R,-W) (optional) (1-byte) |
| // |
| // Arc Interval |
| // ARC interval: See clause A.1.4.3. (R,-W) (optional) (1-byte) |
| // |
| // Optical Signal Level |
| // Optical signal level: This attribute reports the current measurement of total downstream optical |
| // power. Its value is a 2s complement integer referred to 1-mW (i.e., dBm), with 0.002-dB |
| // granularity. (R) (optional) (2-bytes) |
| // |
| // Lower Optical Threshold |
| // Lower optical threshold: This attribute specifies the optical level that the RE uses to declare |
| // the downstream low received optical power alarm. Valid values are -127-dBm (coded as 254) to |
| // 0-dBm (coded as 0) in 0.5-dB increments. The default value 0xFF selects the RE's internal |
| // policy. (R,-W) (optional) (1-byte) |
| // |
| // Upper Optical Threshold |
| // Upper optical threshold: This attribute specifies the optical level that the RE uses to declare |
| // the downstream high received optical power alarm. Valid values are -127-dBm (coded as 254) to |
| // 0-dBm (coded as 0) in 0.5 dB increments. The default value 0xFF selects the RE's internal |
| // policy. (R,-W) (optional) (1-byte) |
| // |
| // Transmit Optical Level |
| // Transmit optical level: This attribute reports the current measurement of mean optical launch |
| // power. Its value is a 2s complement integer referred to 1-mW (i.e., dBm), with 0.002-dB |
| // granularity. (R) (optional) (2-bytes) |
| // |
| // Lower Transmit Power Threshold |
| // Lower transmit power threshold: This attribute specifies the minimum mean optical launch power |
| // that the RE uses to declare the low transmit optical power alarm. Its value is a 2s-complement |
| // integer referred to 1-mW (i.e., dBm), with 0.5-dB granularity. The default value 0x7F selects |
| // the RE's internal policy. (R,-W) (optional) (1-byte) |
| // |
| // Upper Transmit Power Threshold |
| // Upper transmit power threshold: This attribute specifies the maximum mean optical launch power |
| // that the RE uses to declare the high transmit optical power alarm. Its value is a 2s-complement |
| // integer referred to 1-mW (i.e., dBm), with 0.5-dB granularity. The default value 0x7F selects |
| // the RE's internal policy. (R,-W) (optional) (1-byte) |
| // |
| // Usage Mode |
| // 3 This R'/S' interface is used as the uplink for both the embedded management ONU and one or |
| // more PPTP RE UNI(s) (in a time division fashion). |
| // |
| // Target Upstream Frequency |
| // Target upstream frequency: This attribute specifies the frequency of the converted upstream |
| // signal on the optical trunk line (OTL), in gigahertz. The converted frequency must conform to |
| // the frequency plan specified in [ITUT G.984.6]. The value 0 means that the upstream signal |
| // frequency remains the same as the original frequency; no frequency conversion is done. If the RE |
| // does not support provisionable upstream frequency (wavelength), this attribute should take the |
| // fixed value representing the RE's capability and the RE should deny attempts to set the value of |
| // the attribute. If the RE does support provisionable upstream frequency conversion, the default |
| // value of this attribute is 0. (R, W) (optional) (4 bytes). |
| // |
| // Target Downstream Frequency |
| // Target downstream frequency: This attribute specifies the frequency of the downstream signal |
| // received by the RE on the OTL, in gigahertz. The incoming frequency must conform to the |
| // frequency plan specified in [ITUT G.984.6]. The default value 0 means that the downstream |
| // frequency remains the same as its original frequency; no frequency conversion is done. If the RE |
| // does not support provisionable downstream frequency selectivity, this attribute should take the |
| // fixed value representing the RE's capability, and the RE should deny attempts to set the value |
| // of the attribute. If the RE does support provisionable downstream frequency selectivity, the |
| // default value of this attribute is 0. (R, W) (optional) (4 bytes). |
| // |
| // Upstream Signal Transmission Mode |
| // Upstream signal transmission mode: When true, this Boolean attribute enables conversion from |
| // burst mode to continuous mode. The default value false specifies burst mode upstream |
| // transmission. If the RE does not have the ability to convert from burst to continuous mode |
| // transmission, it should deny attempts to set this attribute to true. (R, W) (optional) (1 byte) |
| // |
| type ReAniG struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| reanigBME = &ManagedEntityDefinition{ |
| Name: "ReAniG", |
| ClassID: 313, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xfffc, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1), |
| 2: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), true, true, false, 2), |
| 3: ByteField("Arc", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), true, true, false, 3), |
| 4: ByteField("ArcInterval", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4), |
| 5: Uint16Field("OpticalSignalLevel", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5), |
| 6: ByteField("LowerOpticalThreshold", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6), |
| 7: ByteField("UpperOpticalThreshold", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7), |
| 8: Uint16Field("TransmitOpticalLevel", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8), |
| 9: ByteField("LowerTransmitPowerThreshold", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, Write), false, true, false, 9), |
| 10: ByteField("UpperTransmitPowerThreshold", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), false, true, false, 10), |
| 11: ByteField("UsageMode", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, Write), false, false, false, 11), |
| 12: Uint32Field("TargetUpstreamFrequency", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, Write), false, true, false, 12), |
| 13: Uint32Field("TargetDownstreamFrequency", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, Write), false, true, false, 13), |
| 14: ByteField("UpstreamSignalTransmissionMode", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read, Write), false, true, false, 14), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewReAniG (class ID 313) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewReAniG(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*reanigBME, params...) |
| } |