| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // TcAdaptorPerformanceMonitoringHistoryDataXdslClassID is the 16-bit ID for the OMCI |
| // Managed entity TC adaptor performance monitoring history data xDSL |
| const TcAdaptorPerformanceMonitoringHistoryDataXdslClassID ClassID = ClassID(116) |
| |
| var tcadaptorperformancemonitoringhistorydataxdslBME *ManagedEntityDefinition |
| |
| // TcAdaptorPerformanceMonitoringHistoryDataXdsl (class ID #116) |
| // This ME collects PM data of an xTUC to xTUR ATM data path. Instances of this ME are created and |
| // deleted by the OLT. |
| // |
| // For a complete discussion of generic PM architecture, refer to clause I.4. |
| // |
| // Relationships |
| // An instance of this ME is associated with an xDSL UNI. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| // identical ID, this ME is implicitly linked to an instance of the PPTP xDSL UNI part 1. (R) |
| // (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| // (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data1/2 ID: This attribute points to an instance of the threshold data1 ME that |
| // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Near_End Hec Violation Count |
| // Near-end HEC violation count: This attribute counts near-end HEC anomalies in the ATM data path. |
| // (R) (mandatory) (2-bytes) |
| // |
| // Near_End Delineated Total Cell Count Cd P |
| // Near-end delineated total cell count (CDP): This attribute counts the total number of cells |
| // passed through the cell delineation and HEC function process operating on the ATM data path |
| // while in the SYNC state. (R) (mandatory) (4-bytes) |
| // |
| // Near_End User Total Cell Count Cu_P |
| // Near-end user total cell count(CU-P): This attribute counts the total number of cells in the ATM |
| // data path delivered at the V-C interface. (R) (mandatory) (4-bytes) |
| // |
| // Near_End Idle Cell Bit Error Count |
| // Near-end idle cell bit error count: This attribute counts cells with bit errors in the ATM data |
| // path idle payload received at the near end. (R) (mandatory) (2-bytes) |
| // |
| // Far_End Hec Violation Count |
| // Far-end HEC violation count: This attribute counts far-end HEC anomalies in the ATM data path. |
| // (R) (mandatory) (2-bytes) |
| // |
| // Far_End Delineated Total Cell Count Cd_Pfe |
| // Far-end delineated total cell count (CD-PFE): This attribute counts the total number of cells |
| // passed through the cell delineation process and HEC function operating on the ATM data path |
| // while in the SYNC state. (R) (mandatory) (4-bytes) |
| // |
| // Far_End User Total Cell Count Cu_Pfe |
| // Far-end user total cell count (CU-PFE): This attribute counts the total number of cells in the |
| // ATM data path delivered at the T-R interface. (R) (mandatory) (4-bytes) |
| // |
| // Far_End Idle Cell Bit Error Count |
| // Far-end idle cell bit error count: This attribute counts cells with bit errors in the ATM data |
| // path idle payload received at the far end. (R) (mandatory) (2-bytes) |
| // |
| type TcAdaptorPerformanceMonitoringHistoryDataXdsl struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| tcadaptorperformancemonitoringhistorydataxdslBME = &ManagedEntityDefinition{ |
| Name: "TcAdaptorPerformanceMonitoringHistoryDataXdsl", |
| ClassID: 116, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xffc0, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint16Field("NearEndHecViolationCount", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint32Field("NearEndDelineatedTotalCellCountCdP", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 5: Uint32Field("NearEndUserTotalCellCountCuP", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 6: Uint16Field("NearEndIdleCellBitErrorCount", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 7: Uint16Field("FarEndHecViolationCount", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 8: Uint32Field("FarEndDelineatedTotalCellCountCdPfe", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 9: Uint32Field("FarEndUserTotalCellCountCuPfe", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9), |
| 10: Uint16Field("FarEndIdleCellBitErrorCount", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewTcAdaptorPerformanceMonitoringHistoryDataXdsl (class ID 116) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewTcAdaptorPerformanceMonitoringHistoryDataXdsl(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*tcadaptorperformancemonitoringhistorydataxdslBME, params...) |
| } |