blob: e1cb44f8d8afe4cefab576804d8bd7b6cad486d4 [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// MplsPseudowireTerminationPointClassID is the 16-bit ID for the OMCI
// Managed entity MPLS pseudowire termination point
const MplsPseudowireTerminationPointClassID ClassID = ClassID(333)
var mplspseudowireterminationpointBME *ManagedEntityDefinition
// MplsPseudowireTerminationPoint (class ID #333)
// This ME contains the configuration data of a pseudowire whose underlying transport method is
// MPLS. Instances of this ME are created and deleted by the OLT.
//
// Relationships
// Zero or one instance of this ME is associated with each instance of the pseudowire TP ME.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. (R,
// setbycreate)-(mandatory) (2 bytes)
//
// Tp Type
// (R, W, setbycreate) (mandatory) (1 byte)
//
// Tp Pointer
// TP pointer: This attribute points to the instance of the TP associated with this MPLS PW TP. The
// type of the associated TP is determined by the TP type attribute. (R, W, setbycreate)
// (mandatory) (2 bytes)
//
// Mpls Label Indicator
// (R, W, setbycreate) (mandatory) (1 byte)
//
// Mpls Pw Direction
// (R, W, setbycreate) (mandatory) (1 byte)
//
// Mpls Pw Uplink Label
// MPLS PW uplink label: This attribute specifies the label of the inner MPLS pseudowire upstream.
// The attribute is not meaningful for unidirectional downstream PWs. (R, W, setbycreate)
// (mandatory) (4 bytes)
//
// Mpls Pw Downlink Label
// MPLS PW downlink label: This attribute specifies the label of the inner MPLS pseudowire
// downstream. The attribute is not meaningful for unidirectional upstream PWs. (R, W, setbycreate)
// (mandatory) (4 bytes)
//
// Mpls Pw Tc
// NOTE 1 - The TC field was previously known as EXP. Refer to [bIETF-RFC-5462].
//
// Mpls Tunnel Direction
// (R, W, setbycreate) (mandatory for double-labelled case) (1 byte)
//
// Mpls Tunnel Uplink Label
// MPLS tunnel uplink label: This attribute specifies the (outer) label for the upstream MPLS
// tunnel. If the MPLS tunnel is downstream only, this attribute should be set to 0. (R, W,
// setbycreate) (mandatory for double-labelled case) (4 bytes)
//
// Mpls Tunnel Downlink Label
// MPLS tunnel downlink label: This attribute specifies the (outer) label for the downstream MPLS
// tunnel. If the MPLS tunnel is upstream only, this attribute should be set to 0. (R, W,
// setbycreate) (mandatory for double-labelled case) (4 bytes)
//
// Mpls Tunnel Tc
// NOTE 2 - The TC field was previously known as EXP. Refer to [bIETF-RFC-5462].
//
// Pseudowire Type
// (R, W, setbycreate) (mandatory) (2 bytes)
//
// Pseudowire Control Word Preference
// Pseudowire control word preference: When set to true, this Boolean attribute specifies that a
// control word is to be sent with each packet. Some PW types mandate the use of a control word in
// any event. In such cases, the value configured for this attribute has no effect on the presence
// of the control word. (R, W, setbycreate) (optional) (1 byte)
//
// Administrative State
// Administrative state: This attribute locks (1) and unlocks (0) the functions performed by the
// MPLS pseudowire TP. Administrative state is further described in clause-A.1.6. (R,-W) (optional)
// (1-byte)
//
// Operational State
// Operational state: This attribute reports whether the ME is currently capable of performing its
// function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte)
//
type MplsPseudowireTerminationPoint struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
mplspseudowireterminationpointBME = &ManagedEntityDefinition{
Name: "MplsPseudowireTerminationPoint",
ClassID: 333,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
),
AllowedAttributeMask: 0xfffe,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("TpType", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1),
2: Uint16Field("TpPointer", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: ByteField("MplsLabelIndicator", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 3),
4: ByteField("MplsPwDirection", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 4),
5: Uint32Field("MplsPwUplinkLabel", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 5),
6: Uint32Field("MplsPwDownlinkLabel", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 6),
7: ByteField("MplsPwTc", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 7),
8: ByteField("MplsTunnelDirection", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 8),
9: Uint32Field("MplsTunnelUplinkLabel", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 9),
10: Uint32Field("MplsTunnelDownlinkLabel", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 10),
11: ByteField("MplsTunnelTc", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 11),
12: Uint16Field("PseudowireType", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 12),
13: ByteField("PseudowireControlWordPreference", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 13),
14: ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read, Write), false, true, false, 14),
15: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x0002, 0, mapset.NewSetWith(Read), true, true, false, 15),
},
Access: CreatedByOlt,
Support: UnknownSupport,
}
}
// NewMplsPseudowireTerminationPoint (class ID 333) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewMplsPseudowireTerminationPoint(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*mplspseudowireterminationpointBME, params...)
}