| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // ReCommonAmplifierParametersClassID is the 16-bit ID for the OMCI |
| // Managed entity RE common amplifier parameters |
| const ReCommonAmplifierParametersClassID ClassID = ClassID(328) |
| |
| var recommonamplifierparametersBME *ManagedEntityDefinition |
| |
| // ReCommonAmplifierParameters (class ID #328) |
| // This ME organizes data associated with each OA supported by the RE. The management ONU |
| // automatically creates one instance of this ME for each upstream or downstream OA. |
| // |
| // Relationships |
| // An instance of this ME is associated with an instance of the RE downstream amplifier or RE |
| // upstream amplifier ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // NOTE - The type of the linked ME can be determined by uniqueness of slot and port. |
| // |
| // Gain |
| // Gain: This attribute reports the current measurement of the OA's gain, in decibels. Its value is |
| // a 2s complement integer with 0.25-dB granularity, and with a range from -32-dB to 31.5-dB. The |
| // value 0x7F indicates that the current measured gain is 0, i.e., negative infinity in decibels |
| // terms. (R) (optional) (1-byte) |
| // |
| // Lower Gain Threshold |
| // Lower gain threshold: This attribute specifies the gain the RE uses to declare the low gain |
| // alarm. Valid values are 0-dB (coded as 0x00) to 63.5-dB (coded as 0xFE). The default value 0xFF |
| // selects the RE's internal policy. (R,-W) (optional) (1-byte) |
| // |
| // Upper Gain Threshold |
| // Upper gain threshold: This attribute specifies the gain the RE uses to declare the high gain |
| // alarm. Valid values are 0-dB (coded as 0x00) to 63.5-dB (coded as 0xFE). The default value 0xFF |
| // selects the RE's internal policy. (R,-W) (optional) (1-byte) |
| // |
| // Target Gain |
| // Target gain: This attribute specifies the target gain, when the operational mode of the parent |
| // RE downstream or upstream amplifier is set to constant gain mode. Valid values are 0-dB (coded |
| // as 0x00) to 63.5-dB (coded as 0xFE). The default value 0xFF selects the RE's internal policy. |
| // (R,-W) (optional) (1-byte) |
| // |
| // Device Temperature |
| // Device temperature: This attribute reports the temperature in degrees Celcius of the active |
| // device (SOA or pump) in the OA. Its value is a 2s complement integer with granularity |
| // 1/256-degree-C. (R) (optional) (2-bytes) |
| // |
| // Lower Device Temperature Threshold |
| // Lower device temperature threshold: This attribute is a 2s complement integer that specifies the |
| // temperature the RE uses to declare the low temperature alarm. Valid values are -64 to |
| // +63-degree-C in 0.5-degree-C increments. The default value 0x7F selects the RE's internal |
| // policy. (R,-W) (optional) (1-byte) |
| // |
| // Upper Device Temperature Threshold |
| // Upper device temperature threshold: This attribute is a 2s complement integer that specifies the |
| // temperature the RE uses to declare the high temperature alarm. Valid values are -64 to |
| // +63-degree-C in 0.5-degree-C increments. The default value 0x7F selects the RE's internal |
| // policy. (R,-W) (optional) (1-byte) |
| // |
| // Device Bias Current |
| // Device bias current: This attribute contains the measured bias current applied to the SOA or |
| // pump laser. Its value is an unsigned integer with granularity 2-mA. Valid values are 0 to |
| // 512-mA. (R) (optional) (1-byte) |
| // |
| // Amplifier Saturation Output Power |
| // Amplifier saturation output power: This attribute reports the saturation output power of the |
| // amplifier as specified by the manufacturer. Its value is an unsigned integer referred to 1-mW |
| // (i.e., dBm), with 0.1-dB granularity. (R) (optional) (2-bytes) |
| // |
| // Amplifier Noise Figure |
| // Amplifier noise figure: This attribute reports the intrinsic noise figure of the amplifier, as |
| // specified by the manufacturer. Its value is an unsigned integer with 0.1-dB granularity (R) |
| // (optional) (1-byte) |
| // |
| // Amplifier Saturation Gain |
| // Amplifier saturation gain: This attribute reports the gain of the amplifier at saturation, as |
| // specified by the manufacturer. Its value is an unsigned integer with 0.25-dB granularity, and |
| // with a range from 0 to 63.75-dB. (R) (optional) (1-byte) |
| // |
| type ReCommonAmplifierParameters struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| recommonamplifierparametersBME = &ManagedEntityDefinition{ |
| Name: "ReCommonAmplifierParameters", |
| ClassID: 328, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xffe0, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: ByteField("Gain", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, true, false, 1), |
| 2: ByteField("LowerGainThreshold", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, true, false, 2), |
| 3: ByteField("UpperGainThreshold", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, true, false, 3), |
| 4: ByteField("TargetGain", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4), |
| 5: Uint16Field("DeviceTemperature", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5), |
| 6: ByteField("LowerDeviceTemperatureThreshold", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6), |
| 7: ByteField("UpperDeviceTemperatureThreshold", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7), |
| 8: ByteField("DeviceBiasCurrent", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8), |
| 9: Uint16Field("AmplifierSaturationOutputPower", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, true, false, 9), |
| 10: ByteField("AmplifierNoiseFigure", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, true, false, 10), |
| 11: ByteField("AmplifierSaturationGain", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewReCommonAmplifierParameters (class ID 328) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewReCommonAmplifierParameters(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*recommonamplifierparametersBME, params...) |
| } |