| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // Vdsl2LineInventoryAndStatusDataPart3ClassID is the 16-bit ID for the OMCI |
| // Managed entity VDSL2 line inventory and status data part 3 |
| const Vdsl2LineInventoryAndStatusDataPart3ClassID ClassID = ClassID(170) |
| |
| var vdsl2lineinventoryandstatusdatapart3BME *ManagedEntityDefinition |
| |
| // Vdsl2LineInventoryAndStatusDataPart3 (class ID #170) |
| // This ME extends the other xDSL line inventory and status data MEs with attributes specific to |
| // VDSL2. This ME contains per-band attributes for both directions. These same attributes are |
| // defined in the xDSL line inventory and status data part 2 ME, but only for a single band. [ITUT |
| // G.993.2] allows for VDSL2 to have as many as five bands upstream and as many as five bands |
| // downstream. |
| // |
| // Relationships |
| // This is one of the status data MEs associated with an xDSL UNI. It is required only if VDSL2 is |
| // supported by the PPTP. The ONU automatically creates or deletes an instance of this ME upon |
| // creation or deletion of a PPTP xDSL UNI part 1 that supports these attributes. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| // identical ID, this ME is implicitly linked to an instance of the PPTP xDSL UNI part 1 ME. (R) |
| // (mandatory) (2-bytes) |
| // |
| // Downstream Line Attenuation Per Band |
| // Downstream line attenuation per band: The LATNds attribute is defined per usable band. It is the |
| // squared magnitude of the channel characteristics function, H(f), averaged over this band, and |
| // measured during loop diagnostic mode and initialization. The exact definition is included in the |
| // relevant xDSL Recommendation. The upstream line attenuation per band ranges from 0 (0.0-dB) to |
| // 1270 (+127.0-dB). The special value 0xFFFF indicates that the line attenuation per band is out |
| // of the range to be represented. (R) (mandatory) (3-bands * 2-bytes-=-6-bytes) |
| // |
| // Upstream Line Attenuation Per Band |
| // Upstream line attenuation per band: The LATNus attribute is defined per usable band. It is the |
| // squared magnitude of the channel characteristics function H(f) averaged over this band, and |
| // measured during loop diagnostic mode and initialization. The exact definition is included in the |
| // relevant xDSL Recommendation. The upstream line attenuation per band ranges from 0 (0.0-dB) to |
| // 1270 (+127.0-dB). The special value 0xFFFF indicates that line attenuation per band is out of |
| // range to be represented. (R) (mandatory) (4-bands * 2-bytes-=-8-bytes) |
| // |
| // Downstream Signal Attenuation Per Band |
| // NOTE 1 - During showtime, only a subset of the subcarriers may be transmitted by the xTU-C, as |
| // compared to loop diagnostic mode and initialization. Therefore, the downstream signal |
| // attenuation value during showtime may be significantly lower than the downstream signal |
| // attenuation value during loop diagnostic mode and initialization. |
| // |
| // Upstream Signal Attenuation Per Band |
| // NOTE 2 - During showtime, only a subset of the subcarriers may be transmitted by the xTU-R, as |
| // compared to loop diagnostic mode and initialization. Therefore, the upstream signal attenuation |
| // value during showtime may be significantly lower than the upstream signal attenuation value |
| // during loop diagnostic mode and initialization. |
| // |
| // Downstream Snr Margin Per Band |
| // Downstream SNR margin per band: The SNRMpbds attribute is defined per usable band. The |
| // downstream SNR margin per band is the maximum increase of noise power received at the xTU-R, |
| // such that the BER requirements are met for all downstream bearer channels. Each array value |
| // ranges from 0 (-64.0-dB) to 1270 (+63.0-dB). The special value 0xFFFF indicates that the |
| // attribute is out of range to be represented. (R) (mandatory) (3 bands * 2-bytes-=-6-bytes) |
| // |
| // Upstream Snr Margin Per Band |
| // Upstream SNR margin per band: The SNRMpbus attribute is defined per usable band. The upstream |
| // SNR margin per band is the maximum increase of noise power received at the xTU-C, such that the |
| // BER requirements are met for all upstream bearer channels. Each array value ranges from 0 |
| // (-64.0-dB) to 1270 (+63.0-dB). The special value 0xFFFF indicates that the attribute is out of |
| // range to be represented. (R) (mandatory) (4 bands * 2-bytes-= 8-bytes) |
| // |
| type Vdsl2LineInventoryAndStatusDataPart3 struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| vdsl2lineinventoryandstatusdatapart3BME = &ManagedEntityDefinition{ |
| Name: "Vdsl2LineInventoryAndStatusDataPart3", |
| ClassID: 170, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| ), |
| AllowedAttributeMask: 0xfc00, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: MultiByteField("DownstreamLineAttenuationPerBand", OctetsAttributeType, 0x8000, 3, toOctets("AAAA"), mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint32Field("UpstreamLineAttenuationPerBand", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), false, false, false, 2), |
| 3: MultiByteField("DownstreamSignalAttenuationPerBand", OctetsAttributeType, 0x2000, 3, toOctets("AAAA"), mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint32Field("UpstreamSignalAttenuationPerBand", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 5: MultiByteField("DownstreamSnrMarginPerBand", OctetsAttributeType, 0x0800, 3, toOctets("AAAA"), mapset.NewSetWith(Read), false, false, false, 5), |
| 6: Uint32Field("UpstreamSnrMarginPerBand", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewVdsl2LineInventoryAndStatusDataPart3 (class ID 170) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewVdsl2LineInventoryAndStatusDataPart3(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*vdsl2lineinventoryandstatusdatapart3BME, params...) |
| } |