blob: 9cdd51c086e5812393d08ca40a003f110a36213b [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// EthernetPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity Ethernet performance monitoring history data
const EthernetPerformanceMonitoringHistoryDataClassID ClassID = ClassID(24)
var ethernetperformancemonitoringhistorydataBME *ManagedEntityDefinition
// EthernetPerformanceMonitoringHistoryData (class ID #24)
// This ME collects some of the PM data for a physical Ethernet interface. Instances of this ME are
// created and deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the PPTP Ethernet UNI.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an
// identical ID, this ME is implicitly linked to an instance of the PPTP Ethernet UNI. (R,
// setbycreate) (mandatory) (2-bytes)
//
// Interval End Time
// Interval end time: This attribute identifies the most recently finished 15-min interval. (R)
// (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
// that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Fcs Errors
// FCS errors: This attribute counts frames received on a particular interface that were an
// integral number of octets in length but failed the FCS check. The count is incremented when the
// MAC service returns the frameCheckError status to the link layer control (LLC) or other MAC
// user. Received frames for which multiple error conditions are obtained are counted according to
// the error status presented to the LLC. (R) (mandatory) (4-bytes)
//
// Excessive Collision Counter
// Excessive collision counter: This attribute counts frames whose transmission failed due to
// excessive collisions.-(R) (mandatory) (4-bytes)
//
// Late Collision Counter
// Late collision counter: This attribute counts the number of times that a collision was detected
// later than 512 bit times into the transmission of a packet. (R) (mandatory) (4-bytes)
//
// Frames Too Long
// Frames too long: This attribute counts received frames that exceeded the maximum permitted frame
// size. The count is incremented when the MAC service returns the frameTooLong status to the LLC.
// (R) (mandatory) (4-bytes)
//
// Buffer Overflows On Receive
// Buffer overflows on receive: This attribute counts the number of times that the receive buffer
// overflowed. (R) (mandatory) (4-bytes)
//
// Buffer Overflows On Transmit
// Buffer overflows on transmit: This attribute counts the number of times that the transmit buffer
// overflowed. (R) (mandatory) (4-bytes)
//
// Single Collision Frame Counter
// Single collision frame counter: This attribute counts successfully transmitted frames whose
// transmission was delayed by exactly one collision. (R) (mandatory) (4-bytes)
//
// Multiple Collisions Frame Counter
// Multiple collisions frame counter: This attribute counts successfully transmitted frames whose
// transmission was delayed by more than one collision. (R) (mandatory) (4-bytes)
//
// Sqe Counter
// SQE counter: This attribute counts the number of times that the SQE test error message was
// generated by the PLS sublayer. (R) (mandatory) (4-bytes)
//
// Deferred Transmission Counter
// Deferred transmission counter: This attribute counts frames whose first transmission attempt was
// delayed because the medium was busy. The count does not include frames involved in collisions.
// (R) (mandatory) (4-bytes)
//
// Internal Mac Transmit Error Counter
// Internal MAC transmit error counter: This attribute counts frames whose transmission failed due
// to an internal MAC sublayer transmit error. (R) (mandatory) (4-bytes)
//
// Carrier Sense Error Counter
// Carrier sense error counter: This attribute counts the number of times that carrier sense was
// lost or never asserted when attempting to transmit a frame. (R) (mandatory) (4-bytes)
//
// Alignment Error Counter
// Alignment error counter: This attribute counts received frames that were not an integral number
// of octets in length and did not pass the FCS check. (R) (mandatory) (4-bytes)
//
// Internal Mac Receive Error Counter
// Internal MAC receive error counter: This attribute counts frames whose reception failed due to
// an internal MAC sublayer receive error. (R) (mandatory) (4-bytes)
//
type EthernetPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
ethernetperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "EthernetPerformanceMonitoringHistoryData",
ClassID: 24,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
),
AllowedAttributeMask: 0xffff,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", PointerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("FcsErrors", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("ExcessiveCollisionCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field("LateCollisionCounter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field("FramesTooLong", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint32Field("BufferOverflowsOnReceive", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
8: Uint32Field("BufferOverflowsOnTransmit", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
9: Uint32Field("SingleCollisionFrameCounter", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9),
10: Uint32Field("MultipleCollisionsFrameCounter", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10),
11: Uint32Field("SqeCounter", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11),
12: Uint32Field("DeferredTransmissionCounter", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12),
13: Uint32Field("InternalMacTransmitErrorCounter", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, false, false, 13),
14: Uint32Field("CarrierSenseErrorCounter", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, false, false, 14),
15: Uint32Field("AlignmentErrorCounter", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, false, false, 15),
16: Uint32Field("InternalMacReceiveErrorCounter", CounterAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, false, false, 16),
},
Access: CreatedByOlt,
Support: UnknownSupport,
}
}
// NewEthernetPerformanceMonitoringHistoryData (class ID 24) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewEthernetPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*ethernetperformancemonitoringhistorydataBME, params...)
}