| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // ReDownstreamAmplifierClassID is the 16-bit ID for the OMCI |
| // Managed entity RE downstream amplifier |
| const ReDownstreamAmplifierClassID ClassID = ClassID(316) |
| |
| var redownstreamamplifierBME *ManagedEntityDefinition |
| |
| // ReDownstreamAmplifier (class ID #316) |
| // This ME organizes data associated with each OA for downstream data supported by the RE. The |
| // management ONU automatically creates one instance of this ME for each downstream OA as follows. |
| // |
| // o When the RE has mid-span PON RE downstream OA ports built into its factory configuration. |
| // |
| // o When a cardholder is provisioned to expect a circuit pack of the mid-span PON RE downstream OA |
| // type. |
| // |
| // o When a cardholder provisioned for plug-and-play is equipped with a circuit pack of the midspan |
| // PON RE downstream OA type. Note that the installation of a plug-and-play card may indicate the |
| // presence of a mid-span PON RE downstream OA via equipment ID as well as its type attribute, and |
| // indeed may cause the management ONU to instantiate a port-mapping package to specify the ports |
| // precisely. |
| // |
| // The management ONU automatically deletes instances of this ME when a cardholder is neither |
| // provisioned to expect a mid-span PON RE downstream OA circuit pack, nor is it equipped with a |
| // mid-span PON RE downstream OA circuit pack. |
| // |
| // Relationships |
| // An instance of this ME is associated with a downstream OA and with an instance of a circuit |
| // pack. If the RE includes OEO regeneration in either direction, the RE downstream amplifier is |
| // also associated with an RE ANI-G. Refer to clause-9.14.1 for further discussion. |
| // |
| // Attributes |
| // Managed Entity Id |
| // NOTE 1 - This ME ID may be identical to that of an RE ANI-G if it shares the same physical slot- |
| // port. |
| // |
| // Administrative State |
| // NOTE 2- When an RE supports multiple PONs, or protected access to a single PON, its primary |
| // ANI-G cannot be completely shut down, due to a loss of the management communications capability. |
| // Complete blocking of service and removal of power may nevertheless be appropriate for secondary |
| // RE ANI-Gs. Administrative lock suppresses alarms and notifications for both primary and |
| // secondary RE ANI-Gs. Administrative lock suppresses alarms and notifications for an RE |
| // downstream amplifier, be it either primary or secondary. |
| // |
| // Operational State |
| // Operational state: This attribute indicates whether the ME is capable of performing its |
| // function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte) |
| // |
| // Arc |
| // ARC: See clause A.1.4.3. (R,-W) (optional) (1-byte) |
| // |
| // Arc Interval |
| // ARC interval: See clause A.1.4.3. (R,-W) (optional) (1-byte) |
| // |
| // Operational Mode |
| // (R,W) (mandatory) (1-byte) |
| // |
| // Input Optical Signal Level |
| // Input optical signal level: This attribute reports the current measurement of the input optical |
| // signal power of the downstream OA. Its value is a 2s-complement integer referred to 1-mW (i.e., |
| // dBm), with 0.002-dB granularity. (R) (optional) (2-bytes) |
| // |
| // Lower Input Optical Threshold |
| // Lower input optical threshold: This attribute specifies the optical level the RE uses to declare |
| // the low received optical power alarm. Valid values are -127-dBm (coded as 254) to 0-dBm (coded |
| // as 0) in 0.5-dB increments. The default value 0xFF selects the RE's internal policy. (R,-W) |
| // (optional) (1-byte) |
| // |
| // Upper Input Optical Threshold |
| // Upper input optical threshold: This attribute specifies the optical level the RE uses to declare |
| // the high received optical power alarm. Valid values are -127-dBm (coded as 254) to 0-dBm (coded |
| // as 0) in 0.5-dB increments. The default value 0xFF selects the RE's internal policy. (R,-W) |
| // (optional) (1-byte) |
| // |
| // Output Optical Signal Level |
| // Output optical signal level: This attribute reports the current measurement of the mean optical |
| // launch power of the downstream OA. Its value is a 2s-complement integer referred to 1-mW (i.e., |
| // dBm), with 0.002-dB granularity. (R) (optional) (2-bytes) |
| // |
| // Lower Output Optical Threshold |
| // Lower output optical threshold: This attribute specifies the minimum mean optical launch power |
| // that the RE uses to declare the low transmit optical power alarm. Its value is a 2s complement |
| // integer referred to 1-mW (i.e., dBm), with 0.5-dB granularity. The default value 0x7F selects |
| // the RE's internal policy. (R,-W) (optional) (1-byte) |
| // |
| // Upper Output Optical Threshold |
| // Upper output optical threshold: This attribute specifies the maximum mean optical launch power |
| // that the RE uses to declare the high transmit optical power alarm. Its value is a 2s complement |
| // integer referred to 1-mW (i.e., dBm), with 0.5-dB granularity. The default value 0x7F selects |
| // the RE's internal policy. (R,-W) (optional) (1-byte) |
| // |
| // R'S' Splitter Coupling Ratio |
| // R'S' splitter coupling ratio: This attribute reports the coupling ratio of the splitter at the |
| // R'/S' interface that connects the embedded management ONU and the amplifiers to the OTL. Valid |
| // values are 99:1 (coded as 99-decimal) to 1:99 (coded as 1 decimal), where the first value is the |
| // value encoded and is the percentage of the optical signal connected to the amplifier. The |
| // default value 0xFF indicates that there is no splitter connected to this upstream/downstream |
| // amplifier pair. (R) (optional) (1-byte) |
| // |
| type ReDownstreamAmplifier struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| redownstreamamplifierBME = &ManagedEntityDefinition{ |
| Name: "ReDownstreamAmplifier", |
| ClassID: 316, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| Test, |
| ), |
| AllowedAttributeMask: 0xfff0, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1), |
| 2: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), true, true, false, 2), |
| 3: ByteField("Arc", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), true, true, false, 3), |
| 4: ByteField("ArcInterval", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4), |
| 5: ByteField("OperationalMode", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5), |
| 6: Uint16Field("InputOpticalSignalLevel", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, true, false, 6), |
| 7: ByteField("LowerInputOpticalThreshold", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7), |
| 8: ByteField("UpperInputOpticalThreshold", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8), |
| 9: Uint16Field("OutputOpticalSignalLevel", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, true, false, 9), |
| 10: ByteField("LowerOutputOpticalThreshold", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), false, true, false, 10), |
| 11: ByteField("UpperOutputOpticalThreshold", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, Write), false, true, false, 11), |
| 12: ByteField("R'S'SplitterCouplingRatio", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, true, false, 12), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewReDownstreamAmplifier (class ID 316) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewReDownstreamAmplifier(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*redownstreamamplifierBME, params...) |
| } |