| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // XdslLineInventoryAndStatusDataPart1ClassID is the 16-bit ID for the OMCI |
| // Managed entity xDSL line inventory and status data part 1 |
| const XdslLineInventoryAndStatusDataPart1ClassID ClassID = ClassID(100) |
| |
| var xdsllineinventoryandstatusdatapart1BME *ManagedEntityDefinition |
| |
| // XdslLineInventoryAndStatusDataPart1 (class ID #100) |
| // This ME contains part 1 of the line inventory and status data for an xDSL UNI. The ONU |
| // automatically creates or deletes an instance of this ME upon the creation or deletion of a PPTP |
| // xDSL UNI part 1. |
| // |
| // Relationships |
| // An instance of this ME is associated with an xDSL UNI. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| // identical ID, this ME is implicitly linked to an instance of the PPTP xDSL UNI part 1. (R) |
| // (mandatory) (2-bytes) |
| // |
| // Xtu_C G.994.1 Vendor Id |
| // xTU-C G.994.1 vendor ID: This is the vendor ID as inserted by the xTU-C in the ITUT-G.994.1 CL |
| // message. It comprises 8 octets, including a country code followed by a (regionally allocated) |
| // provider code, as defined in [ITUT-T.35]. (R) (mandatory) (8-bytes) |
| // |
| // Xtu_R G.994.1 Vendor Id |
| // xTU-R G.994.1 vendor ID: This is the vendor ID as inserted by the xTU-R in the ITUT-G.994.1 CLR |
| // message. It comprises 8 binary octets, with the same format as the xTUC ITUT G.994.1 vendor ID. |
| // (R) (mandatory) (8-bytes) |
| // |
| // Xtu_C System Vendor Id |
| // xTU-C system vendor ID: This is the vendor ID as inserted by the xTU-C in the overhead messages |
| // of [ITU-T G.992.3] and [ITU-T G.992.4]. It comprises 8 binary octets, with the same format as |
| // the xTU-C ITUT-G.994.1 vendor ID. (R) (mandatory) (8-bytes) |
| // |
| // Xtu_R System Vendor Id |
| // xTU-R system vendor ID: This is the vendor ID as inserted by the xTU-R in the embedded |
| // operations channel and overhead messages of [ITU-T G.992.3] and [ITUT-G.992.4]. It comprises 8 |
| // binary octets, with the same format as the xTU-C ITUT-G.994.1 vendor ID. (R) (mandatory) |
| // (8-bytes) |
| // |
| // Xtu_C Version Number |
| // xTU-C version number: This is the vendorspecific version number as inserted by the xTUC in the |
| // overhead messages of [ITU-T G.992.3] and [ITU-T G.992.4]. It comprises up to 16 binary octets. |
| // (R) (mandatory) (16-bytes) |
| // |
| // Xtu_R Version Number |
| // xTU-R version number: This is the version number as inserted by the xTUR in the embedded |
| // operations channel of [ITU-T G.992.1] or [ITU-T G.992.2], or the overhead messages of [ITU-T |
| // G.992.3], [ITU-T G.992.4], [ITU-T G.992.5] and [ITU-T G.993.2]. The attribute value may be |
| // vendor-specific, but is recommended to comprise up to 16 ASCII characters, null-terminated if it |
| // is shorter than 16. The string should contain the xTU-R firmware version and the xTU-R model, |
| // encoded in that order and separated by a space character: "<xTU-R firmware version><xTU-R |
| // model>". It is recognized that legacy xTU-Rs may not support this format. (R) (mandatory) |
| // (16-bytes) |
| // |
| // Xtu_C Serial Number Part 1 |
| // xTU-C serial number part 1: The vendorspecific serial number inserted by the xTU-C in the |
| // overhead messages of [ITU-T G.992.3] and [ITU-T G.992.4] comprises up to 32 ASCII characters, |
| // null terminated if it is shorter than 32 characters. This attribute contains the first 16 |
| // characters. (R) (mandatory) (16-bytes) |
| // |
| // Xtu_C Serial Number Part 2 |
| // xTU-C serial number part 2: This attribute contains the second 16 characters of the xTU-C serial |
| // number. (R) (mandatory) (16-bytes) |
| // |
| // Xtu_R Serial Number Part 1 |
| // xTU-R serial number part 1: The serial number inserted by the xTU-R in the embedded operations |
| // channel of [ITU-T G.992.1] or [ITU-T G.992.2], or the overhead messages of [ITU-T G.992.3], |
| // [ITU-T G.992.4], [ITU-T G.992.5] and [ITUT-G.993.2], comprises up to 32 ASCII characters, |
| // nullterminated if it is shorter than 32. It is recommended that the equipment serial number, the |
| // equipment model and the equipment firmware version, encoded in that order and separated by space |
| // characters, be contained: "<equipment serial number><equipment model><equipment firmware |
| // version>". It is recognized that legacy xTU-Rs may not support this format. This attribute |
| // contains the first 16 characters. (R) (mandatory) (16-bytes) |
| // |
| // Xtu_R Serial Number Part 2 |
| // xTU-R serial number part 2: This attribute contains the second 16 characters of the xTU-R serial |
| // number. (R) (mandatory) (16-bytes) |
| // |
| // Xtu_C Self Test Results |
| // xTU-C selftest results: This parameter reports the xTU-C self-test result. It is coded in two |
| // fields. The most significant octet is 0 if the self-test passed and 1 if it failed. The three |
| // least significant octets are a vendor-discretionary integer that can be interpreted in |
| // combination with [ITU-T G.994.1] and the system vendor ID. (R) (mandatory) (4-bytes) |
| // |
| // Xtu_R Self Test Results |
| // xTU-R selftest results: This parameter defines the xTU-R self-test result. It is coded in two |
| // fields. The most significant octet is 0 if the self-test passed and 1 if it failed. The three |
| // least significant octets are a vendor-discretionary integer that can be interpreted in |
| // combination with [ITU-T G.994.1] and the system vendor ID. (R) (mandatory) (4-bytes) |
| // |
| // Xtu_C Transmission System Capability |
| // NOTE 1 - This attribute is only 7-bytes long. An eighth byte identifying VDSL2 capabilities is |
| // defined in the VDSL2 line inventory and status data part 1 ME. |
| // |
| // Xtu_R Transmission System Capability |
| // NOTE 2 - This attribute is only 7-bytes long. An eighth byte identifying VDSL2 capabilities is |
| // defined in the VDSL2 line inventory and status data part 2 ME. |
| // |
| // Initialization Success_Failure Cause |
| // (R) (mandatory) (1-byte) |
| // |
| type XdslLineInventoryAndStatusDataPart1 struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| xdsllineinventoryandstatusdatapart1BME = &ManagedEntityDefinition{ |
| Name: "XdslLineInventoryAndStatusDataPart1", |
| ClassID: 100, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| ), |
| AllowedAttributeMask: 0xfffe, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: Uint64Field("XtuCG9941VendorId", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint64Field("XtuRG9941VendorId", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read), false, false, false, 2), |
| 3: Uint64Field("XtuCSystemVendorId", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint64Field("XtuRSystemVendorId", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 5: MultiByteField("XtuCVersionNumber", OctetsAttributeType, 0x0800, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 5), |
| 6: MultiByteField("XtuRVersionNumber", OctetsAttributeType, 0x0400, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 6), |
| 7: MultiByteField("XtuCSerialNumberPart1", OctetsAttributeType, 0x0200, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 7), |
| 8: MultiByteField("XtuCSerialNumberPart2", OctetsAttributeType, 0x0100, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 8), |
| 9: MultiByteField("XtuRSerialNumberPart1", OctetsAttributeType, 0x0080, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 9), |
| 10: MultiByteField("XtuRSerialNumberPart2", OctetsAttributeType, 0x0040, 16, toOctets("AAAAAAAAAAAAAAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 10), |
| 11: Uint32Field("XtuCSelfTestResults", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11), |
| 12: Uint32Field("XtuRSelfTestResults", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12), |
| 13: MultiByteField("XtuCTransmissionSystemCapability", OctetsAttributeType, 0x0008, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 13), |
| 14: MultiByteField("XtuRTransmissionSystemCapability", OctetsAttributeType, 0x0004, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, false, false, 14), |
| 15: ByteField("InitializationSuccessFailureCause", UnsignedIntegerAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, false, false, 15), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewXdslLineInventoryAndStatusDataPart1 (class ID 100) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewXdslLineInventoryAndStatusDataPart1(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*xdsllineinventoryandstatusdatapart1BME, params...) |
| } |