| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // XgPonDownstreamManagementPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI |
| // Managed entity XG-PON downstream management performance monitoring history data |
| const XgPonDownstreamManagementPerformanceMonitoringHistoryDataClassID ClassID = ClassID(345) |
| |
| var xgpondownstreammanagementperformancemonitoringhistorydataBME *ManagedEntityDefinition |
| |
| // XgPonDownstreamManagementPerformanceMonitoringHistoryData (class ID #345) |
| // This ME collects PM data associated with the XG-PON TC layer. It collects counters associated |
| // with downstream PLOAM and OMCI messages. |
| // |
| // For a complete discussion of generic PM architecture, refer to clause I.4. |
| // |
| // Relationships |
| // An instance of this ME is associated with an ANI-G. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| // identical ID, this ME is implicitly linked to an instance of the ANI-G. (R, set-by-create) |
| // (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| // (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| // data 2 ME is optional. (R,-W, set-by-create) (mandatory) (2-bytes) |
| // |
| // Ploam Message Integrity Check Mic Error Count |
| // PLOAM message integrity check (MIC) error count: This attribute counts MIC errors detected in |
| // downstream PLOAM messages, either directed to this ONU or broadcast to all ONUs. (R) (optional) |
| // (4-bytes) |
| // |
| // Downstream Ploam Messages Count |
| // Downstream PLOAM messages count: This attribute counts PLOAM messages received, either directed |
| // to this ONU or broadcast to all ONUs. (R) (optional) (4-bytes) |
| // |
| // Profile Messages Received |
| // Profile messages received: This attribute counts the number of profile messages received, either |
| // directed to this ONU or broadcast to all ONUs. In [ITU-T G.9807.1], this attribute is used for |
| // received burst_profile message count. (R) (optional) (4-bytes) |
| // |
| // Ranging_Time Messages Received |
| // Ranging_time messages received: This attribute counts the number of ranging_time messages |
| // received, either directed to this ONU or broadcast to all ONUs. (R) (mandatory) (4-bytes) |
| // |
| // Deactivate_Onu_Id Messages Received |
| // Deactivate_ONU-ID messages received: This attribute counts the number of deactivate_ONU-ID |
| // messages received, either directed to this ONU or broadcast to all ONUs. Deactivate_ONU-ID |
| // messages do not reset this counter. (R) (optional) (4-bytes) |
| // |
| // Disable_Serial_Number Messages Received |
| // Disable_serial_number messages received: This attribute counts the number of |
| // disable_serial_number messages received, whose serial number specified this ONU. (R) (optional) |
| // (4-bytes) |
| // |
| // Request_Registration Messages Received |
| // Request_registration messages received: This attribute counts the number of request_registration |
| // messages received. (R) (optional) (4-bytes) |
| // |
| // Assign_Alloc_Id Messages Received |
| // Assign_alloc-ID messages received: This attribute counts the number of assign_alloc-ID messages |
| // received. (R) (optional) (4-bytes) |
| // |
| // Key_Control Messages Received |
| // Key_control messages received: This attribute counts the number of key_control messages |
| // received, either directed to this ONU or broadcast to all ONUs. (R) (optional) (4-bytes) |
| // |
| // Sleep_Allow Messages Received |
| // Sleep_allow messages received: This attribute counts the number of sleep_allow messages |
| // received, either directed to this ONU or broadcast to all ONUs. (R) (optional) (4-bytes) |
| // |
| // Baseline Omci Messages Received Count |
| // Baseline OMCI messages received count: This attribute counts the number of OMCI messages |
| // received in the baseline message format. (R) (optional) (4-bytes) |
| // |
| // Extended Omci Messages Received Count |
| // Extended OMCI messages received count: This attribute counts the number of OMCI messages |
| // received in the extended message format. (R) (optional) (4-bytes) |
| // |
| // Assign_Onu_Id Messages Received |
| // Assign_ONU-ID messages received: This attribute counts the number of assign_ONU-ID messages |
| // received since the last re-boot. (R) (optional) (4-bytes) |
| // |
| // Omci Mic Error Count |
| // OMCI MIC error count: This attribute counts MIC errors detected in OMCI messages directed to |
| // this ONU. (R) (optional) (4-bytes) |
| // |
| type XgPonDownstreamManagementPerformanceMonitoringHistoryData struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| xgpondownstreammanagementperformancemonitoringhistorydataBME = &ManagedEntityDefinition{ |
| Name: "XgPonDownstreamManagementPerformanceMonitoringHistoryData", |
| ClassID: 345, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xffff, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", PointerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint32Field("PloamMessageIntegrityCheckMicErrorCount", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, true, false, 3), |
| 4: Uint32Field("DownstreamPloamMessagesCount", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4), |
| 5: Uint32Field("ProfileMessagesReceived", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5), |
| 6: Uint32Field("RangingTimeMessagesReceived", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 7: Uint32Field("DeactivateOnuIdMessagesReceived", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, true, false, 7), |
| 8: Uint32Field("DisableSerialNumberMessagesReceived", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8), |
| 9: Uint32Field("RequestRegistrationMessagesReceived", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, true, false, 9), |
| 10: Uint32Field("AssignAllocIdMessagesReceived", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, true, false, 10), |
| 11: Uint32Field("KeyControlMessagesReceived", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11), |
| 12: Uint32Field("SleepAllowMessagesReceived", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, true, false, 12), |
| 13: Uint32Field("BaselineOmciMessagesReceivedCount", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, true, false, 13), |
| 14: Uint32Field("ExtendedOmciMessagesReceivedCount", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, true, false, 14), |
| 15: Uint32Field("AssignOnuIdMessagesReceived", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, true, false, 15), |
| 16: Uint32Field("OmciMicErrorCount", CounterAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, true, false, 16), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewXgPonDownstreamManagementPerformanceMonitoringHistoryData (class ID 345) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewXgPonDownstreamManagementPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*xgpondownstreammanagementperformancemonitoringhistorydataBME, params...) |
| } |