| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // MgcPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI |
| // Managed entity MGC performance monitoring history data |
| const MgcPerformanceMonitoringHistoryDataClassID ClassID = ClassID(156) |
| |
| var mgcperformancemonitoringhistorydataBME *ManagedEntityDefinition |
| |
| // MgcPerformanceMonitoringHistoryData (class ID #156) |
| // The MGC monitoring data ME provides run-time statistics for an active MGC association. Instances |
| // of this ME are created and deleted by the OLT. |
| // |
| // For a complete discussion of generic PM architecture, refer to clause I.4. |
| // |
| // Relationships |
| // An instance of this ME is associated with an instance of the MGC config data or MGC config |
| // portal ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| // identical ID, this ME is implicitly linked to an instance of the associated MGC config data or |
| // to the MGC config portal ME. If a non-OMCI configuration method is used for VoIP, there can be |
| // only one live ME instance, associated with the MGC config portal, and with ME ID 0. (R, |
| // setbycreate) (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| // (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Received Messages |
| // Received messages: This attribute counts the number of received Megaco messages on this |
| // association, as defined by [ITUT H.341]. (R) (mandatory) (4-bytes) |
| // |
| // Received Octets |
| // Received octets: This attribute counts the total number of octets received on this association, |
| // as defined by [ITU-T H.341]. (R) (mandatory) (4-bytes) |
| // |
| // Sent Messages |
| // Sent messages: This attribute counts the total number of Megaco messages sent over this |
| // association, as defined by [ITU-T H.341]. (R) (mandatory) (4-bytes) |
| // |
| // Sent Octets |
| // Sent octets: This attribute counts the total number of octets sent over this association, as |
| // defined by [ITU-T H.341]. (R) (mandatory) (4-bytes) |
| // |
| // Protocol Errors |
| // (R) (mandatory) (4-bytes) |
| // |
| // Transport Losses |
| // Transport losses: This attribute counts the total number of transport losses (e.g., socket |
| // problems) detected on this association. A link loss is defined as loss of communication with the |
| // remote entity due to hardware/transient problems, or problems in related software. (R) |
| // (mandatory) (4-bytes) |
| // |
| // Last Detected Event |
| // (R) (mandatory) (1-byte) |
| // |
| // Last Detected Event Time |
| // Last detected event time: This attribute reports the time in seconds since the last event on |
| // this association was detected, as defined by [ITU-T H.341]. (R) (mandatory) (4-bytes) |
| // |
| // Last Detected Reset Time |
| // Last detected reset time: This attribute reports the time in seconds since these statistics were |
| // last reset, as defined by [ITU-T H.341]. Under normal circumstances, a get action on this |
| // attribute would return 900-s to indicate a completed 15-min interval. (R) (mandatory) (4-bytes) |
| // |
| type MgcPerformanceMonitoringHistoryData struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| mgcperformancemonitoringhistorydataBME = &ManagedEntityDefinition{ |
| Name: "MgcPerformanceMonitoringHistoryData", |
| ClassID: 156, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| GetCurrentData, |
| ), |
| AllowedAttributeMask: 0xffe0, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint32Field("ReceivedMessages", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint32Field("ReceivedOctets", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 5: Uint32Field("SentMessages", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 6: Uint32Field("SentOctets", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 7: Uint32Field("ProtocolErrors", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 8: Uint32Field("TransportLosses", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 9: ByteField("LastDetectedEvent", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9), |
| 10: Uint32Field("LastDetectedEventTime", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10), |
| 11: Uint32Field("LastDetectedResetTime", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 0: "MGCP protocol errors", |
| 1: "MGCP transport losses", |
| }, |
| } |
| } |
| |
| // NewMgcPerformanceMonitoringHistoryData (class ID 156) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewMgcPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*mgcperformancemonitoringhistorydataBME, params...) |
| } |