| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // InterworkingVccTerminationPointClassID is the 16-bit ID for the OMCI |
| // Managed entity Interworking VCC termination point |
| const InterworkingVccTerminationPointClassID ClassID = ClassID(14) |
| |
| var interworkingvccterminationpointBME *ManagedEntityDefinition |
| |
| // InterworkingVccTerminationPoint (class ID #14) |
| // An instance of this ME represents a point in the ONU where the IW of a service or underlying |
| // physical infrastructure (e.g., ADSL) to an ATM layer takes place. At this point, ATM cells are |
| // generated from a bit stream (e.g., Ethernet) or a bit stream is reconstructed from ATM cells. |
| // |
| // Instances of this ME are created and deleted by the OLT. |
| // |
| // Relationships |
| // One instance of this ME exists for each occurrence of transformation of a data stream into ATM |
| // cells and vice versa. |
| // |
| // Attributes |
| // Managed Entity Id |
| // Managed entity ID: This attribute uniquely identifies each instance of this ME. (R,-setbycreate) |
| // (mandatory) (2-bytes) |
| // |
| // Vci Value |
| // VCI value: This attribute identifies the VCI value associated with this IW VCC TP. (R,-W, |
| // setbycreate) (mandatory) (2-bytes) |
| // |
| // Vp Network Ctp Connectivity Pointer |
| // VP network CTP connectivity pointer: This attribute points to the VP network CTP associated with |
| // this IW VCC TP. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Deprecated 1 |
| // Deprecated 1: Not used; should be set to 0. (R,-W, setbycreate) (mandatory) (1-byte) |
| // |
| // Deprecated 2 |
| // Deprecated 2: Not used; should be set to 0. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Aal5 Profile Pointer |
| // AAL5 profile pointer: This attribute points to an instance of the AAL5 profile. (R,-W, |
| // setbycreate) (mandatory) (2-bytes) |
| // |
| // Deprecated 3 |
| // Deprecated 3: Not used; should be set to 0. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Aal Loopback Configuration |
| // The default value of this attribute is 0. (R,-W) (mandatory) (1-byte) |
| // |
| // Pptp Counter |
| // PPTP counter: This value is the number of instances of PPTP MEs associated with this instance of |
| // the IW VCC TP. (R) (optional) (1-byte) |
| // |
| // Operational State |
| // Operational state: This attribute indicates whether the ME is capable of performing its |
| // function. Valid values are enabled (0) and disabled (1). (R) (optional) (1-byte) |
| // |
| type InterworkingVccTerminationPoint struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| interworkingvccterminationpointBME = &ManagedEntityDefinition{ |
| Name: "InterworkingVccTerminationPoint", |
| ClassID: 14, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xff80, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: Uint16Field("VciValue", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1), |
| 2: Uint16Field("VpNetworkCtpConnectivityPointer", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: ByteField("Deprecated1", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, 3), |
| 4: Uint16Field("Deprecated2", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, 4), |
| 5: Uint16Field("Aal5ProfilePointer", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 5), |
| 6: Uint16Field("Deprecated3", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, 6), |
| 7: ByteField("AalLoopbackConfiguration", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, false, false, 7), |
| 8: ByteField("PptpCounter", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8), |
| 9: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read), true, true, false, 9), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 0: "End-to-end VC AIS layer management indication receiving (LMIR)", |
| 1: "End-to-end VC RDI LMIR", |
| 2: "End-to-end VC AIS layer management indication generation (LMIG)", |
| 3: "End-to-end VC RDI LMIG", |
| 4: "Segment loss of continuity", |
| 5: "End-to-end loss of continuity", |
| 6: "CSA", |
| }, |
| } |
| } |
| |
| // NewInterworkingVccTerminationPoint (class ID 14) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewInterworkingVccTerminationPoint(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*interworkingvccterminationpointBME, params...) |
| } |