| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // EponDownstreamPerformanceMonitoringConfigurationClassID is the 16-bit ID for the OMCI |
| // Managed entity EPON downstream performance monitoring configuration |
| const EponDownstreamPerformanceMonitoringConfigurationClassID = ClassID(406) // 0x0196 |
| |
| var epondownstreamperformancemonitoringconfigurationBME *ManagedEntityDefinition |
| |
| // EponDownstreamPerformanceMonitoringConfiguration (Class ID: #406 / 0x0196) |
| // This ME represents window sizes and threshold values for EPON downstream PM operations which are |
| // defined in [IEEE 802.3] as: errored symbol period, errored frame, errored frame period and |
| // errored frame seconds summary. |
| // |
| // The EPON ONU automatically instantiates an instance of this ME for each ANI-E. |
| // |
| // Relationships |
| // An instance of this ME is associated with an ANI-E. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is |
| // implicitly linked to an instance of the ANI-E. (R, set-by-create) (mandatory) (2-bytes) |
| // |
| // Errored Symbol Period Window |
| // This attribute specifies the number of symbols in the measurement period, as defined in clause |
| // 57.5.3.1 of [IEEE 802.3]. (R, W) (optional) (8-bytes) |
| // |
| // Errored Symbol Period Threshold |
| // This attribute specifies the threshold of errored symbols for generating an event report, as |
| // defined in clause 57.5.3.1 of [IEEE 802.3]. (R, W) (optional) (8-bytes) |
| // |
| // Errored Frame Window |
| // This attribute specifies the duration in units of 100-ms of the measurement period, as defined |
| // in clause 57.5.3.2 of [IEEE 802.3]. (R, W) (optional) (2-bytes) |
| // |
| // Errored Frame Threshold |
| // This attribute specifies the threshold of errored frames for generating an event report, as |
| // defined in clause 57.5.3.2 of [IEEE 802.3]. (R, W) (optional) (4-bytes) |
| // |
| // Errored Frame Period Window |
| // This attribute specifies the duration in terms of frames of the measurement period, as defined |
| // in clause 57.5.3.3 of [IEEE 802.3]. (R, W) (optional) (4-bytes) |
| // |
| // Errored Frame Period Threshold |
| // This attribute specifies the threshold of errored frames for generating an event report, as |
| // defined in clause 57.5.3.3 of [IEEE 802.3]. (R, W) (optional) (4-bytes) |
| // |
| // Errored Frame Seconds Summary Window |
| // This attribute specifies the duration in units of 100ms of the measurement period, as defined in |
| // clause-57.5.3.4 of [IEEE-802.3]. (R, W) (optional) (2-bytes) |
| // |
| // Errored Frame Seconds Summary Threshold |
| // This attribute specifies the threshold of errored frame seconds for generating an event report, |
| // as defined in clause 57.5.3.4 of [IEEE 802.3]. (R, W) (optional) (2-bytes) |
| // |
| type EponDownstreamPerformanceMonitoringConfiguration struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| epondownstreamperformancemonitoringconfigurationBME = &ManagedEntityDefinition{ |
| Name: "EponDownstreamPerformanceMonitoringConfiguration", |
| ClassID: 406, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xff00, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: Uint64Field("ErroredSymbolPeriodWindow", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, true, false, 1), |
| 2: Uint64Field("ErroredSymbolPeriodThreshold", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, true, false, 2), |
| 3: Uint16Field("ErroredFrameWindow", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, true, false, 3), |
| 4: Uint32Field("ErroredFrameThreshold", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4), |
| 5: Uint32Field("ErroredFramePeriodWindow", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, true, false, 5), |
| 6: Uint32Field("ErroredFramePeriodThreshold", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6), |
| 7: Uint16Field("ErroredFrameSecondsSummaryWindow", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7), |
| 8: Uint16Field("ErroredFrameSecondsSummaryThreshold", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewEponDownstreamPerformanceMonitoringConfiguration (class ID 406) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewEponDownstreamPerformanceMonitoringConfiguration(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*epondownstreamperformancemonitoringconfigurationBME, params...) |
| } |