blob: 8ee5afc0ad58d57ff84aa1dab56f58905584be6b [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// EponDownstreamPerformanceMonitoringConfigurationClassID is the 16-bit ID for the OMCI
// Managed entity EPON downstream performance monitoring configuration
const EponDownstreamPerformanceMonitoringConfigurationClassID = ClassID(406) // 0x0196
var epondownstreamperformancemonitoringconfigurationBME *ManagedEntityDefinition
// EponDownstreamPerformanceMonitoringConfiguration (Class ID: #406 / 0x0196)
// This ME represents window sizes and threshold values for EPON downstream PM operations which are
// defined in [IEEE 802.3] as: errored symbol period, errored frame, errored frame period and
// errored frame seconds summary.
//
// The EPON ONU automatically instantiates an instance of this ME for each ANI-E.
//
// Relationships
// An instance of this ME is associated with an ANI-E.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to an instance of the ANI-E. (R, set-by-create) (mandatory) (2-bytes)
//
// Errored Symbol Period Window
// This attribute specifies the number of symbols in the measurement period, as defined in clause
// 57.5.3.1 of [IEEE 802.3]. (R, W) (optional) (8-bytes)
//
// Errored Symbol Period Threshold
// This attribute specifies the threshold of errored symbols for generating an event report, as
// defined in clause 57.5.3.1 of [IEEE 802.3]. (R, W) (optional) (8-bytes)
//
// Errored Frame Window
// This attribute specifies the duration in units of 100-ms of the measurement period, as defined
// in clause 57.5.3.2 of [IEEE 802.3]. (R, W) (optional) (2-bytes)
//
// Errored Frame Threshold
// This attribute specifies the threshold of errored frames for generating an event report, as
// defined in clause 57.5.3.2 of [IEEE 802.3]. (R, W) (optional) (4-bytes)
//
// Errored Frame Period Window
// This attribute specifies the duration in terms of frames of the measurement period, as defined
// in clause 57.5.3.3 of [IEEE 802.3]. (R, W) (optional) (4-bytes)
//
// Errored Frame Period Threshold
// This attribute specifies the threshold of errored frames for generating an event report, as
// defined in clause 57.5.3.3 of [IEEE 802.3]. (R, W) (optional) (4-bytes)
//
// Errored Frame Seconds Summary Window
// This attribute specifies the duration in units of 100ms of the measurement period, as defined in
// clause-57.5.3.4 of [IEEE-802.3]. (R, W) (optional) (2-bytes)
//
// Errored Frame Seconds Summary Threshold
// This attribute specifies the threshold of errored frame seconds for generating an event report,
// as defined in clause 57.5.3.4 of [IEEE 802.3]. (R, W) (optional) (2-bytes)
//
type EponDownstreamPerformanceMonitoringConfiguration struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
epondownstreamperformancemonitoringconfigurationBME = &ManagedEntityDefinition{
Name: "EponDownstreamPerformanceMonitoringConfiguration",
ClassID: 406,
MessageTypes: mapset.NewSetWith(
Get,
Set,
),
AllowedAttributeMask: 0xff00,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: Uint64Field("ErroredSymbolPeriodWindow", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, true, false, 1),
2: Uint64Field("ErroredSymbolPeriodThreshold", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, true, false, 2),
3: Uint16Field("ErroredFrameWindow", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, true, false, 3),
4: Uint32Field("ErroredFrameThreshold", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4),
5: Uint32Field("ErroredFramePeriodWindow", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, true, false, 5),
6: Uint32Field("ErroredFramePeriodThreshold", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, true, false, 6),
7: Uint16Field("ErroredFrameSecondsSummaryWindow", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, true, false, 7),
8: Uint16Field("ErroredFrameSecondsSummaryThreshold", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, true, false, 8),
},
Access: CreatedByOnu,
Support: UnknownSupport,
}
}
// NewEponDownstreamPerformanceMonitoringConfiguration (class ID 406) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewEponDownstreamPerformanceMonitoringConfiguration(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*epondownstreamperformancemonitoringconfigurationBME, params...)
}