| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // MocaInterfacePerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI |
| // Managed entity MoCA interface performance monitoring history data |
| const MocaInterfacePerformanceMonitoringHistoryDataClassID = ClassID(164) // 0x00a4 |
| |
| var mocainterfaceperformancemonitoringhistorydataBME *ManagedEntityDefinition |
| |
| // MocaInterfacePerformanceMonitoringHistoryData (Class ID: #164 / 0x00a4) |
| // This ME collects PM data for an MoCA interface. Instances of this ME are created and deleted by |
| // the OLT. |
| // |
| // NOTE - The structure of this ME is an exception to the normal definition of PM MEs and normal PM |
| // behaviour (clause I.4). It should not be used as a guide for the definition of future MEs. Among |
| // other exceptions, this ME contains only current values, which are retrievable by get and get |
| // next operations; no history is retained. |
| // |
| // Relationships |
| // An instance of this ME is associated with an instance of the PPTP MoCA UNI ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is |
| // implicitly linked to an instance of the PPTP MoCA UNI. (R, setbycreate) (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Phy T X Broadcast Rate |
| // PHY Tx broadcast rate: This attribute indicates the MoCA PHY broadcast transmit rate from the |
| // ONU MoCA interface to all the nodes in bits per second. (R) (optional) (4-bytes) |
| // |
| // Node Table |
| // Rx packet: Number of packets received from the node. (4-bytes) |
| // |
| // Rx errored and missed: Number of errored and missed packets received from the node. The sum of |
| // this field across all entries in the node table contributes to the Rx errored and missed TCA. |
| // This field is reset to 0 on 15-min boundaries. (4-bytes) |
| // |
| // Rx errored: Number of errored packets received from the node. The sum of this field across all |
| // entries in the node table contributes to the Rx errored TCA. This field is reset to 0 on 15-min |
| // boundaries. (optional) (4-bytes) |
| // |
| // (R) (mandatory) (37 * N bytes, where N is the number of nodes in the node table) |
| // |
| // This attribute lists current nodes in the node table. The table contains MAC addresses and |
| // statistics for those nodes. These table attributes are further described in the following. Space |
| // for nonsupported optional fields must be allocated in table records, and filled with zero bytes. |
| // |
| // MAC address: A unique identifier of a node within the table. (6-bytes) |
| // |
| // PHY Tx rate: MoCA PHY unicast transmit rate from the ONU MoCA interface to the node identified |
| // by the MAC address, in bits per second. (4-bytes) |
| // |
| // Tx power control reduction: The reduction in transmitter level due to power control, in |
| // decibels. Valid values range from 0 (full power) to 60. (1-byte) |
| // |
| // PHY Rx rate: MoCA PHY unicast receive rate to the ONU MoCA interface from the node identified by |
| // the MAC address, in bits per second. (optional) (4-bytes) |
| // |
| // Rx power level: The power level received at the ONU MoCA interface from the node identified by |
| // the MAC address, in decibel-milliwatts, represented as a 2s complement integer. Valid values |
| // range from +10 (0x0A) to -80 (0xB0). (1-byte) |
| // |
| // PHY Rx broadcast rate: MoCA PHY broadcast receive rate to the ONU MoCA interface from the node |
| // identified by MAC address, in bits per second. (optional) (4-bytes) |
| // |
| // Rx broadcast power level: The power level received at the ONU MoCA interface from the node |
| // identified by the MAC address, in decibel-milliwatts, represented as a 2s complement integer. |
| // Valid values range from +10-(0x0A) to -80 (0xB0). (1-byte) |
| // |
| // Tx packet: Number of packets transmitted to the node. (4-bytes) |
| // |
| type MocaInterfacePerformanceMonitoringHistoryData struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| mocainterfaceperformancemonitoringhistorydataBME = &ManagedEntityDefinition{ |
| Name: "MocaInterfacePerformanceMonitoringHistoryData", |
| ClassID: 164, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| GetNext, |
| Set, |
| ), |
| AllowedAttributeMask: 0xf000, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint32Field("PhyTXBroadcastRate", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, true, false, 3), |
| 4: TableField("NodeTable", TableAttributeType, 0x1000, TableInfo{nil, 37}, mapset.NewSetWith(Read), false, false, false, 4), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 0: "Total rx errored and missed", |
| 1: "Total rx errored", |
| }, |
| } |
| } |
| |
| // NewMocaInterfacePerformanceMonitoringHistoryData (class ID 164) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewMocaInterfacePerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*mocainterfaceperformancemonitoringhistorydataBME, params...) |
| } |