| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // OnuPowerSheddingClassID is the 16-bit ID for the OMCI |
| // Managed entity ONU power shedding |
| const OnuPowerSheddingClassID = ClassID(133) // 0x0085 |
| |
| var onupowersheddingBME *ManagedEntityDefinition |
| |
| // OnuPowerShedding (Class ID: #133 / 0x0085) |
| // This ME models the ONU's ability to shed services when the ONU goes into battery operation mode |
| // after AC power failure. Shedding classes are defined in the following table, which may span |
| // multiple circuit pack types. This feature works in conjunction with the power shed override |
| // attribute of the circuit pack ME, which can selectively prevent power shedding of priority |
| // ports. |
| // |
| // An ONU that supports power shedding automatically creates an instance of this ME. |
| // |
| // The following table defines the binding of shedding class and PPTP type. The coding is taken |
| // from Table 9.1.5-1. In the case of hybrid circuit pack types, multiple shedding classes may |
| // affect a circuit pack if the hardware is capable of partial power shedding. |
| // |
| // An ONU may choose to model its ports with the port-mapping package of clause 9.1.8, rather than |
| // with real or virtual circuit packs. In this case, power shedding pertains to individual PPTPs |
| // (listed in column 2 of the table). |
| // |
| // Relationships |
| // One instance of this ME is associated with the ONU ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. There is only one instance, number |
| // 0. (R) (mandatory) (2-bytes) |
| // |
| // Restore Power Timer Reset Interval |
| // The time delay, in seconds, before resetting the power-shedding timers after full power |
| // restoration. Upon ME instantiation, the ONU sets this attribute to 0. (R,-W) (mandatory) |
| // (2-bytes) |
| // |
| // For each class of service (CoS), an interval attribute is defined below. The value 0 disables |
| // power shedding, while the value 1 enables immediate power shedding, i.e., as soon as AC power |
| // fails. Other values specify the time, in seconds, to keep the service active after AC failure |
| // before shutting them down and shedding power. Upon ME instantiation, the ONU sets each of the |
| // interval attributes to 0. |
| // |
| // Data Class Shedding Interval |
| // (R,-W) (mandatory) (2-bytes) |
| // |
| // Voice Class Shedding Interval |
| // This attribute only pertains to voice services that terminate on the ONU and are under the |
| // management control of the OMCI. (R,-W) (mandatory) (2-bytes) |
| // |
| // Video Overlay Class Shedding Interval |
| // (R,-W) (mandatory) (2-bytes) |
| // |
| // Video Return Class Shedding Interval |
| // (R,-W) (mandatory) (2-bytes) |
| // |
| // Digital Subscriber Line Class Shedding Interval |
| // Digital subscriber line (DSL) class shedding interval: (R,-W) (mandatory) (2-bytes) |
| // |
| // Atm Class Shedding Interval |
| // (R,-W) (mandatory) (2-bytes) |
| // |
| // Ces Class Shedding Interval |
| // (R,-W) (mandatory) (2-bytes) |
| // |
| // Frame Class Shedding Interval |
| // (R,-W) (mandatory) (2-bytes) |
| // |
| // Sdh_Sonet Class Shedding Interval |
| // Sdh-sonet class shedding interval: (R,-W) (mandatory) (2-bytes) |
| // |
| // Shedding Status |
| // Binary indication of power-shedding status for each shedding class. If this 2 byte field is |
| // depicted 0b ABCD EFGH IJKL MNOP, its bits are assigned as follows- |
| // |
| // A Data class |
| // |
| // B Voice class |
| // |
| // C Video overlay class |
| // |
| // D Video return class |
| // |
| // E DSL class |
| // |
| // F ATM class |
| // |
| // G CES class |
| // |
| // H Frame class |
| // |
| // I Sdh-sonet class |
| // |
| // J..P Reserved and set to 0 |
| // |
| // The ONU sets each bit to 1 when power shedding is active, and clears it to 0 when the service is |
| // restored. (R) (optional) (2-bytes) |
| // |
| type OnuPowerShedding struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| onupowersheddingBME = &ManagedEntityDefinition{ |
| Name: "OnuPowerShedding", |
| ClassID: 133, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| Set, |
| ), |
| AllowedAttributeMask: 0xffe0, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: Uint16Field("RestorePowerTimerResetInterval", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, Write), false, false, false, 1), |
| 2: Uint16Field("DataClassSheddingInterval", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, false, false, 2), |
| 3: Uint16Field("VoiceClassSheddingInterval", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, Write), false, false, false, 3), |
| 4: Uint16Field("VideoOverlayClassSheddingInterval", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, false, false, 4), |
| 5: Uint16Field("VideoReturnClassSheddingInterval", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5), |
| 6: Uint16Field("DigitalSubscriberLineClassSheddingInterval", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, Write), false, false, false, 6), |
| 7: Uint16Field("AtmClassSheddingInterval", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, Write), false, false, false, 7), |
| 8: Uint16Field("CesClassSheddingInterval", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, Write), false, false, false, 8), |
| 9: Uint16Field("FrameClassSheddingInterval", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, Write), false, false, false, 9), |
| 10: Uint16Field("SdhSonetClassSheddingInterval", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, Write), false, false, false, 10), |
| 11: Uint16Field("SheddingStatus", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read), true, true, false, 11), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewOnuPowerShedding (class ID 133) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewOnuPowerShedding(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*onupowersheddingBME, params...) |
| } |