| /* |
| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // TwdmChannelTuningPerformanceMonitoringHistoryDataPart2ClassID is the 16-bit ID for the OMCI |
| // Managed entity TWDM channel tuning performance monitoring history data part 2 |
| const TwdmChannelTuningPerformanceMonitoringHistoryDataPart2ClassID = ClassID(450) // 0x01c2 |
| |
| var twdmchanneltuningperformancemonitoringhistorydatapart2BME *ManagedEntityDefinition |
| |
| // TwdmChannelTuningPerformanceMonitoringHistoryDataPart2 (Class ID: #450 / 0x01c2) |
| // This ME collects additional tuning-control-related PM data associated with the slot/circuit |
| // pack, hosting one or more ANI-G MEs, for a specific TWDM channel. Instances of this ME are |
| // created and deleted by the OLT. |
| // |
| // The relevant events this ME is concerned with are counted towards the PM statistics associated |
| // with the source TWDM channel. This ME contains the counters characterized as optional in clause |
| // 14 of [ITU-T- G.989.3]. |
| // |
| // For a complete discussion of generic PM architecture, refer to clause I.4. |
| // |
| // Relationships |
| // An instance of this ME is associated with an instance of TWDM channel ME. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is |
| // implicitly linked to an instance of the TWDM channel ME. (R, setbycreate) (mandatory) (2-bytes) |
| // |
| // Interval End Time |
| // This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte) |
| // |
| // Threshold Data 1_2 Id |
| // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs |
| // that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes) |
| // |
| // Tuning Control Requests Rejected_Ds_Albl |
| // Tuning control requests rejected/DS_ALBL: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and DS_ALBL response code, indicating downstream |
| // administrative label inconsistency. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Ds_Void |
| // Tuning control requests rejected/DS_VOID: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and DS_VOID response code, indicating that the target |
| // downstream wavelength channel descriptor is void. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Ds_Part |
| // Tuning control requests rejected/DS_PART: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and DS_PART response code, indicating that tuning request |
| // involves channel partition violation. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Ds_Tunr |
| // Tuning control requests rejected/DS_TUNR: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and DS_TUNR response code, indicating that the target DS |
| // wavelength channel is out of receiver tuning range. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Ds_Lnrt |
| // Tuning control requests rejected/DS_LNRT: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and DS_LNRT response code, indicating downstream line rate |
| // inconsistency in the target channel. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Ds_Lncd |
| // Tuning control requests rejected/DS_LNCD: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and DS_LNCD response code, indicating downstream line code |
| // inconsistency in the target channel. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Albl |
| // Tuning control requests rejected/US_ALBL: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_ALBL response code, indicating upstream administrative |
| // label inconsistency. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Void |
| // Tuning control requests rejected/US_VOID: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_VOID response code, indicating that the target upstream |
| // wavelength channel descriptor is void. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Tunr |
| // Tuning control requests rejected/US_TUNR: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_TUNR response code, indicating that the target US |
| // wavelength channel is out of transmitter tuning range. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Clbr |
| // Tuning control requests rejected/US_CLBR: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_CLBR response code, indicating that the transmitter has |
| // insufficient calibration accuracy in the target US wavelength channel. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Lktp |
| // Tuning control requests rejected/US_LKTP: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_LKTP response code, indicating upstream optical link |
| // type inconsistency. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Lnrt |
| // Tuning control requests rejected/US_LNRT: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_LNRT response code, indicating upstream line rate |
| // inconsistency in the target channel. (R) (mandatory) (4-byte) |
| // |
| // Tuning Control Requests Rejected_Us_Lncd |
| // Tuning control requests rejected/US_LNCD: The counter of transmitted Tuning_Response PLOAM |
| // messages with NACK operation code and US_LNCD response code, indicating upstream line code |
| // inconsistency in the target channel. (R) (mandatory) (4-byte) |
| // |
| type TwdmChannelTuningPerformanceMonitoringHistoryDataPart2 struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| twdmchanneltuningperformancemonitoringhistorydatapart2BME = &ManagedEntityDefinition{ |
| Name: "TwdmChannelTuningPerformanceMonitoringHistoryDataPart2", |
| ClassID: 450, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| GetCurrentData, |
| ), |
| AllowedAttributeMask: 0xfffe, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 3: Uint32Field("TuningControlRequestsRejectedDsAlbl", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 4: Uint32Field("TuningControlRequestsRejectedDsVoid", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 5: Uint32Field("TuningControlRequestsRejectedDsPart", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 6: Uint32Field("TuningControlRequestsRejectedDsTunr", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 7: Uint32Field("TuningControlRequestsRejectedDsLnrt", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 8: Uint32Field("TuningControlRequestsRejectedDsLncd", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 9: Uint32Field("TuningControlRequestsRejectedUsAlbl", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9), |
| 10: Uint32Field("TuningControlRequestsRejectedUsVoid", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10), |
| 11: Uint32Field("TuningControlRequestsRejectedUsTunr", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11), |
| 12: Uint32Field("TuningControlRequestsRejectedUsClbr", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12), |
| 13: Uint32Field("TuningControlRequestsRejectedUsLktp", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, false, false, 13), |
| 14: Uint32Field("TuningControlRequestsRejectedUsLnrt", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, false, false, 14), |
| 15: Uint32Field("TuningControlRequestsRejectedUsLncd", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, false, false, 15), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| Alarms: AlarmMap{ |
| 0: "Tuning control requests rejected/DS_ALBL", |
| 1: "Tuning control requests rejected/DS_VOID", |
| 2: "Tuning control requests rejected/DS_PART", |
| 3: "Tuning control requests rejected/DS_TUNR", |
| 4: "Tuning control requests rejected/DS_LNRT", |
| 5: "Tuning control requests rejected/DS_LNCD", |
| 6: "Tuning control requests rejected/US_ALBL", |
| 7: "Tuning control requests rejected/US_VOID", |
| 8: "Tuning control requests rejected/US_TUNR", |
| 9: "Tuning control requests rejected/US_CLBR", |
| 10: "Tuning control requests rejected/US_LKTP", |
| 11: "Tuning control requests rejected/US_LNRT", |
| 12: "Tuning control requests rejected/US_LNCD", |
| }, |
| } |
| } |
| |
| // NewTwdmChannelTuningPerformanceMonitoringHistoryDataPart2 (class ID 450) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewTwdmChannelTuningPerformanceMonitoringHistoryDataPart2(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*twdmchanneltuningperformancemonitoringhistorydatapart2BME, params...) |
| } |