| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // VoiceServiceProfileClassID is the 16-bit ID for the OMCI |
| // Managed entity Voice service profile |
| const VoiceServiceProfileClassID = ClassID(58) // 0x003a |
| |
| var voiceserviceprofileBME *ManagedEntityDefinition |
| |
| // VoiceServiceProfile (Class ID: #58 / 0x003a) |
| // This ME organizes data that describe the voice service functions of the ONU. Instances of this |
| // ME are created and deleted by the OLT. |
| // |
| // Relationships |
| // An instance of this ME may be associated with zero or more instances of a VoIP voice CTP by way |
| // of a VoIP media profile. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. (R, setbycreate) (mandatory) |
| // (2-bytes) |
| // |
| // Announcement Type |
| // This attribute specifies the treatment when a subscriber goes off hook but does not attempt a |
| // call within the dial-tone timeout interval. Valid values include the following. |
| // |
| // 0x01 Silence |
| // |
| // 0x02 Reorder tone |
| // |
| // 0x03 Fast busy |
| // |
| // 0x04 Voice announcement |
| // |
| // 0xFF Not specified; ONU is free to make its own choice. |
| // |
| // (R,-W, setbycreate) (mandatory) (1-byte) |
| // |
| // Jitter Target |
| // This attribute specifies the target value of the jitter buffer in milliseconds. The system tries |
| // to maintain the jitter buffer at the target value. The value 0 specifies dynamic jitter buffer |
| // sizing. (R,-W, setbycreate) (optional) (2-bytes) |
| // |
| // Jitter Buffer Max |
| // This attribute specifies the maximum depth of the jitter buffer associated with this service in |
| // milliseconds. The value 0 specifies that the ONU uses its internal default. (R,-W, set-by- |
| // create) (optional) (2-bytes) |
| // |
| // Echo Cancel Ind |
| // The Boolean value true specifies that echo cancellation is on; false specifies off. (R,-W, |
| // setbycreate) (mandatory) (1-byte) |
| // |
| // Pstn Protocol Variant |
| // This attribute controls which variant of POTS signalling is used on the associated UNIs. Its |
| // value is equal to the [ITU-T E.164] country code. The value 0 specifies that the ONU uses its |
| // internal default. (R,-W, set-by-create) (optional) (2-bytes) |
| // |
| // Dtmf Digit Levels |
| // This attribute specifies the power level of DTMF digits that may be generated by the ONU towards |
| // the subscriber set. It is a 2s complement value referred to 1-mW at the 0 transmission level |
| // point (TLP) (dBm0), with resolution 1-dB. The default value 0x8000 selects the ONU's internal |
| // policy. (R, W, setbycreate) (optional) (2-bytes) |
| // |
| // Dtmf Digit Duration |
| // This attribute specifies the duration of DTMF digits that may be generated by the ONU towards |
| // the subscriber set. It is specified in milliseconds. The default value 0 selects the ONU's |
| // internal policy. (R, W, setbycreate) (optional) (2 bytes) |
| // |
| // Hook Flash Minimum Time |
| // This attribute defines the minimum duration recognized by the ONU as a switchhook flash. It is |
| // expressed in milliseconds; the default value 0 selects the ONU's internal policy. (R, W, |
| // setbycreate) (optional) (2 bytes) |
| // |
| // Hook Flash Maximum Time |
| // This attribute defines the maximum duration recognized by the ONU as a switchhook flash. It is |
| // expressed in milliseconds; the default value 0 selects the ONU's internal policy. (R, W, |
| // setbycreate) (optional) (2 bytes) |
| // |
| // Tone Pattern Table |
| // This attribute is a table, each of whose entries specifies a complex tone (or silence) and a |
| // duration. By linking tones and silence together, possibly cyclically, continuous, varying or |
| // interrupted tone sequences, repetitive or not, may be defined. A tone sequence is initiated by |
| // pointing to the first tone pattern table entry that defines its parameters. Each entry is a |
| // vector comprising the following components. |
| // |
| // Index (1 byte): This component is simply an index into the table. It ranges from 1..255. In a |
| // set operation, the value 0 in this field clears the table. |
| // |
| // Tone on (1 byte): This Boolean component controls whether the tone is on (true) or off. If the |
| // tone is off, the frequency and power fields are not meaningful. |
| // |
| // Frequency 1 (2 bytes): This component specifies the frequency of one of the tone components in |
| // hertz. |
| // |
| // Power 1 (1 byte): This component specifies the power level of the corresponding frequency |
| // component. It ranges from 0 (coded as 0) to -25.5 (coded as 255)-dBm0 with 0.1-dB resolution. |
| // |
| // Three additional pairs of frequency-power components may be specified to define a complex tone. |
| // If a pair of possibilities is not to be used, its frequency field should be set to 0. |
| // |
| // Frequency 2 (2 bytes) |
| // |
| // Power 2 (1 byte) |
| // |
| // Frequency 3 (2 bytes) |
| // |
| // Power 3 (1 byte) |
| // |
| // Frequency 4 (2 bytes) |
| // |
| // Power 4 (1 byte) |
| // |
| // The following pair of frequency-power components allows the composite tone to be modulated |
| // (warble effect). If this effect is not to be used, the frequency should be set to 0. |
| // |
| // Modulation frequency (2 bytes), hertz |
| // |
| // Modulation power (1 byte), 0..25.5-dBm0 |
| // |
| // Duration (2 bytes): This component specifies the duration of the phase, in milliseconds. The |
| // value 0 specifies that the phase endures indefinitely, i.e., until terminated by other events |
| // such as call abandonment. |
| // |
| // Next entry (1 byte): This component is a pointer to another entry in this same table, which |
| // permits sequences of tones to be defined, possibly cyclically. A reference to a non-existent |
| // table entry, or the value 0, indicates that the sequence should be terminated. |
| // |
| // (R,-W) (optional) (N * 20 bytes) |
| // |
| // Tone Event Table |
| // This attribute is a table, each of whose entries specifies an event for which a tone is defined. |
| // If the tone can be synthesized by a sequence of complex tones and silence, the event refers to |
| // an entry in the tone pattern table. Otherwise, the event refers to a file name that is expected |
| // to be recognized by the ONU environment. Each entry in the tone event table is a vector |
| // comprising the following components. |
| // |
| // Event (1 byte): This component is an enumeration of the events for which a tone may be defined. |
| // The event component also serves as the index for the table. A set operation to event 0 causes |
| // the table to be cleared. |
| // |
| // Tone pattern (1 byte): This component specifies an entry point into the tone pattern table |
| // attribute, to be invoked when the specified event occurs. The value 0 indicates that no tone |
| // from the tone pattern table is to be played. |
| // |
| // Tone file (2 bytes): This component points to a large string ME that contains the path and name |
| // of a file containing a codec sequence to be played out. If no file is found after traversing |
| // these links, no tone is played. The behaviour is unspecified if both tone pattern and tone file |
| // are specified. |
| // |
| // Tone file repetitions (1 byte): This component specifies the number of times the tone file is to |
| // be repeated. The value 0 means that the file is to be repeated indefinitely until terminated by |
| // some external event such as call abandonment. |
| // |
| // Reserved (2 bytes) |
| // |
| // (R,-W) (optional) (N * 7 bytes). |
| // |
| // Ringing Pattern Table |
| // This attribute is a table, each of whose entries specifies a ringing pattern and a duration. By |
| // linking ringing and silence together, possibly cyclically, continuous or interrupted ringing |
| // sequences, repetitive or not, may be defined. A ringing sequence is initiated by pointing to the |
| // first ringing pattern table entry that defines its parameters. Each entry is a vector comprising |
| // the following components. |
| // |
| // Index (1 byte): This component is simply an index into the table. It ranges from 1..255. In a |
| // set operation, the value 0 in this field clears the table. |
| // |
| // Ringing on (1 byte): This Boolean component controls whether ringing is on (true) or off during |
| // this interval. |
| // |
| // Duration (2 bytes): This component specifies the duration of the ringing phase, in milliseconds. |
| // The value 0 specifies that the phase endures indefinitely, i.e., until terminated by other |
| // events such as call abandonment. |
| // |
| // Next entry (1 byte): This component is a pointer to another entry in this same table, which |
| // permits sequences of ringing bursts to be defined, possibly cyclically. A reference to a non- |
| // existent table entry, or the value 0, indicates that the sequence should be terminated. |
| // |
| // (R,-W) (optional) (N * 5 bytes). |
| // |
| // Ringing Event Table |
| // This attribute is a table, each of whose entries specifies an event for which a ringing sequence |
| // is defined. If the ringing sequence can be generated as a sequence of power ringing and silent |
| // intervals, the event refers to an entry in the ringing pattern table. Otherwise, the event |
| // refers to a file name that is expected to be recognized by the ONU environment. Each entry is a |
| // vector comprising the following components: |
| // |
| // Event (1 byte): This component is an enumeration of the events for which a ringing sequence may |
| // be defined. The event component also serves as the index for the table. A set operation with the |
| // value 0 in this field causes the table to be cleared. |
| // |
| // Ringing pattern (1 byte): This component specifies an entry point into the ringing pattern table |
| // attribute, to be invoked when the specified event occurs. The value 0 indicates that no ringing |
| // sequence is defined in the ringing pattern table. |
| // |
| // Ringing file (2 bytes): This component points to a large string ME that contains the path and |
| // name of a file containing a ring tone to be played out. If no file is found after traversing |
| // these links, no ringing is played. The behaviour is unspecified if both ringing pattern and |
| // ringing file fields are specified. |
| // |
| // Ringing file repetitions (1 byte): This component specifies the number of times the ringing file |
| // is to be repeated. The value 0 means that the file is to be repeated indefinitely until |
| // terminated by some external event such as call abandonment. |
| // |
| // Ringing text (2 bytes): This component points to a large string ME that contains a text string |
| // to be displayed on the CPE device in conjunction with this event. A null pointer indicates that |
| // no text is to be displayed. |
| // |
| // (R,-W) (optional) (N * 7 bytes). |
| // |
| // Network Specific Extensions Pointer |
| // This attribute points to a network address ME that contains the path and name of a file |
| // containing network specific parameters for the associated UNIs. The default value for this |
| // attribute is 0xFFFF, a null pointer. (R,-W, set-by-create) (optional) (2-bytes) |
| // |
| type VoiceServiceProfile struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| voiceserviceprofileBME = &ManagedEntityDefinition{ |
| Name: "VoiceServiceProfile", |
| ClassID: 58, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| Set, |
| SetTable, |
| ), |
| AllowedAttributeMask: 0xfffc, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: ByteField("AnnouncementType", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1), |
| 2: Uint16Field("JitterTarget", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 2), |
| 3: Uint16Field("JitterBufferMax", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 3), |
| 4: ByteField("EchoCancelInd", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 4), |
| 5: Uint16Field("PstnProtocolVariant", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 5), |
| 6: Uint16Field("DtmfDigitLevels", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 6), |
| 7: Uint16Field("DtmfDigitDuration", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 7), |
| 8: Uint16Field("HookFlashMinimumTime", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 8), |
| 9: Uint16Field("HookFlashMaximumTime", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 9), |
| 10: MultiByteField("TonePatternTable", OctetsAttributeType, 0x0040, 20, toOctets("AAAAAAAAAAAAAAAAAAAAAAAAAAA="), mapset.NewSetWith(Read, Write), false, true, false, 10), |
| 11: MultiByteField("ToneEventTable", OctetsAttributeType, 0x0020, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, true, false, 11), |
| 12: MultiByteField("RingingPatternTable", OctetsAttributeType, 0x0010, 5, toOctets("AAAAAAA="), mapset.NewSetWith(Read, Write), false, true, false, 12), |
| 13: MultiByteField("RingingEventTable", OctetsAttributeType, 0x0008, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read, Write), false, true, false, 13), |
| 14: Uint16Field("NetworkSpecificExtensionsPointer", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 14), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewVoiceServiceProfile (class ID 58) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewVoiceServiceProfile(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*voiceserviceprofileBME, params...) |
| } |