blob: bc65164ec8189f0906f1594f44f70d5005fa0e51 [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// XdslXtuCPerformanceMonitoringHistoryDataPart2ClassID is the 16-bit ID for the OMCI
// Managed entity xDSL xTU-C performance monitoring history data part 2
const XdslXtuCPerformanceMonitoringHistoryDataPart2ClassID = ClassID(408) // 0x0198
var xdslxtucperformancemonitoringhistorydatapart2BME *ManagedEntityDefinition
// XdslXtuCPerformanceMonitoringHistoryDataPart2 (Class ID: #408 / 0x0198)
// This ME collects PM data on the xTUC to xTUR path as seen from the xTU-C. Instances of this ME
// are created and deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an xDSL UNI.
//
// Attributes
// Managed Entity Id
// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
// implicitly linked to an instance of the PPTP xDSL UNI part 1. (R, setbycreate) (mandatory)
// (2-bytes)
//
// Interval End Time
// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
// that contain PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Leftr Defect Seconds
// "leftr" defect seconds: If retransmission is used, this attribute is a count of the seconds with
// a near-end ''leftr'' defect present - see clause 7.2.1.1.6 of [ITU-T G.997.1]. (R) (mandatory)
// (2-bytes)
//
// Error_Free Bits Counter
// Error-free bits counter: If retransmission is used, this attribute is a count of the number of
// error-free bits passed over the B1 reference point, divided by 216 - see clause-7.2.1.1.7 of
// [ITU-T G.997.1]. (R) (mandatory) (4-bytes)
//
// Minimum Error_Free Throughput Mineftr
// Minimum error-free throughput (MINEFTR): If retransmission is used, this attribute is the
// minimum error-free throughput in bits per second - see clause 7.2.1.1.8 of [ITUT-G.997.1]. (R)
// (mandatory) (4-bytes)
//
type XdslXtuCPerformanceMonitoringHistoryDataPart2 struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
xdslxtucperformancemonitoringhistorydatapart2BME = &ManagedEntityDefinition{
Name: "XdslXtuCPerformanceMonitoringHistoryDataPart2",
ClassID: 408,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xf800,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint16Field("LeftrDefectSeconds", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("ErrorFreeBitsCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field("MinimumErrorFreeThroughputMineftr", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "leftr defect seconds",
},
}
}
// NewXdslXtuCPerformanceMonitoringHistoryDataPart2 (class ID 408) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewXdslXtuCPerformanceMonitoringHistoryDataPart2(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*xdslxtucperformancemonitoringhistorydatapart2BME, params...)
}