blob: 5ef2495307de1792a699c18edb02d800fc3f1aa8 [file] [log] [blame]
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
* Copyright 2020-present Open Networking Foundation
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// CallControlPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity Call control performance monitoring history data
const CallControlPerformanceMonitoringHistoryDataClassID ClassID = ClassID(140)
var callcontrolperformancemonitoringhistorydataBME *ManagedEntityDefinition
// CallControlPerformanceMonitoringHistoryData (class ID #140)
// This ME collects PM data related to the call control channel. Instances of this ME are created
// and deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME is associated with an instance of the PPTP POTS UNI ME.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an
// identical ID, this ME is implicitly linked to an instance of the PPTP POTS UNI. (R, setbycreate)
// (mandatory) (2-bytes)
//
// Interval End Time
// Interval end time: This attribute identifies the most recently finished 15-min interval. (R)
// (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Call Setup Failures
// Call setup failures: This attribute counts call set-up failures. (R) (mandatory) (4-bytes)
//
// Call Setup Timer
// Call setup timer: This attribute is a high water-mark that records the longest duration of a
// single call set-up detected during this interval. Time is measured in milliseconds from the time
// an initial set-up was requested by the subscriber until the time at which a response was
// provided to the subscriber in the form of busy tone, audible ring tone, etc. (R) (mandatory)
// (4-bytes)
//
// Call Terminate Failures
// Call terminate failures: This attribute counts the number of calls that were terminated with
// cause. (R) (mandatory) (4-bytes)
//
// Analog Port Releases
// Analog port releases: This attribute counts the number of analogue port releases without
// dialling detected (abandoned calls). (R) (mandatory) (4-bytes)
//
// Analog Port Off_Hook Timer
// Analog port off-hook timer: This attribute is a high water-mark that records the longest period
// of a single off-hook detected on the analogue port. Time is measured in milliseconds. (R)
// (mandatory) (4-bytes)
//
type CallControlPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
callcontrolperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "CallControlPerformanceMonitoringHistoryData",
ClassID: 140,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
GetCurrentData,
),
AllowedAttributeMask: 0xfe00,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
3: Uint32Field("CallSetupFailures", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
4: Uint32Field("CallSetupTimer", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
5: Uint32Field("CallTerminateFailures", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
6: Uint32Field("AnalogPortReleases", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
7: Uint32Field("AnalogPortOffHookTimer", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
},
Access: CreatedByOlt,
Support: UnknownSupport,
Alarms: AlarmMap{
0: "CCPM call set-up fail",
1: "CCPM set-up timeout",
2: "CCPM call terminate",
3: "CCPM port release with no dialling",
4: "CCPM port offhook timeout",
},
}
}
// NewCallControlPerformanceMonitoringHistoryData (class ID 140) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewCallControlPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*callcontrolperformancemonitoringhistorydataBME, params...)
}