| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // XdslDownstreamRfiBandsProfileClassID is the 16-bit ID for the OMCI |
| // Managed entity xDSL downstream RFI bands profile |
| const XdslDownstreamRfiBandsProfileClassID = ClassID(111) // 0x006f |
| |
| var xdsldownstreamrfibandsprofileBME *ManagedEntityDefinition |
| |
| // XdslDownstreamRfiBandsProfile (Class ID: #111 / 0x006f) |
| // This ME contains the downstream RFI bands profile for an xDSL UNI. Instances of this ME are |
| // created and deleted by the OLT. |
| // |
| // Relationships |
| // An instance of this ME may be associated with zero or more instances of the PPTP xDSL UNI part |
| // 1. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. The value 0 is reserved. (R, |
| // setbycreate) (mandatory) (2-bytes) |
| // |
| // Downstream Rfi Bands Table |
| // The RFIBANDS attribute is a table where each entry comprises: |
| // |
| // o an entry number field (1-byte, first entry numbered 1); |
| // |
| // o subcarrier index 1 field (2-bytes); |
| // |
| // o subcarrier index 2 field (2-bytes). |
| // |
| // For [ITU-T G.992.5], this configuration attribute defines the subset of downstream PSD mask |
| // breakpoints, as specified in the downstream PSD mask, to be used to notch an RFI band. This |
| // subset consists of couples of consecutive subcarrier indices belonging to breakpoints: [ti; ti-+ |
| // 1], corresponding to the low level of the notch. Interpolation around these points is defined in |
| // [ITUT G.992.5]. |
| // |
| // For [ITU-T G.993.2], this attribute defines the bands where the PSD is to be reduced as |
| // specified in clause 7.2.1.2 of [ITUT G.993.2]. Each band is represented by start and stop |
| // subcarrier indices with a subcarrier spacing of 4.3125-kHz. Up to 16 bands may be specified. |
| // This attribute defines the RFI bands for both upstream and downstream directions. |
| // |
| // Entries have the default value 0 for both subcarrier index 1 and subcarrier index-2. Setting an |
| // entry with a non-zero subcarrier index 1 and subcarrier index-2 implies insertion into the table |
| // or replacement of an existing entry. Setting an entry's subcarrier index 1 and subcarrier index |
| // 2 to 0 implies deletion from the table, if present. |
| // |
| // (R,-W) (mandatory for [ITU-T G.992.5], [ITU-T G.993.2]) (5 * N bytes where N is the number of |
| // RFI bands) |
| // |
| // Bands Valid |
| // This Boolean attribute controls and reports the operational status of the downstream RFI bands |
| // table. |
| // |
| // If this attribute is true, the downstream RFI bands table has been impressed on the DSL |
| // equipment. |
| // |
| // If this attribute is false, the downstream RFI bands table has not been impressed on the DSL |
| // equipment. The default value is false. |
| // |
| // This attribute can be modified by the ONU and OLT, as follows. |
| // |
| // o If the OLT changes any of the RFI bands table entries or sets bands valid false, then bands |
| // valid is false. |
| // |
| // o If bands valid is false and OLT sets bands valid true, the ONU impresses the downstream RFI |
| // bands data on to the DSL equipment. |
| // |
| // (R,-W) (mandatory) (1-byte) |
| // |
| type XdslDownstreamRfiBandsProfile struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| func init() { |
| xdsldownstreamrfibandsprofileBME = &ManagedEntityDefinition{ |
| Name: "XdslDownstreamRfiBandsProfile", |
| ClassID: 111, |
| MessageTypes: mapset.NewSetWith( |
| Create, |
| Delete, |
| Get, |
| GetNext, |
| Set, |
| SetTable, |
| ), |
| AllowedAttributeMask: 0xc000, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 1: TableField("DownstreamRfiBandsTable", TableAttributeType, 0x8000, TableInfo{nil, 5}, mapset.NewSetWith(Read, Write), false, false, false, 1), |
| 2: ByteField("BandsValid", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, Write), false, false, false, 2), |
| }, |
| Access: CreatedByOlt, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewXdslDownstreamRfiBandsProfile (class ID 111) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewXdslDownstreamRfiBandsProfile(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*xdsldownstreamrfibandsprofileBME, params...) |
| } |