| * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
| * Copyright 2020-present Open Networking Foundation |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| /* |
| * NOTE: This file was generated, manual edits will be overwritten! |
| * |
| * Generated by 'goCodeGenerator.py': |
| * https://github.com/cboling/OMCI-parser/README.md |
| */ |
| |
| package generated |
| |
| import "github.com/deckarep/golang-set" |
| |
| // FastLineInventoryAndStatusDataPart2ClassID is the 16-bit ID for the OMCI |
| // Managed entity FAST line inventory and status data part 2 |
| const FastLineInventoryAndStatusDataPart2ClassID = ClassID(436) // 0x01b4 |
| |
| var fastlineinventoryandstatusdatapart2BME *ManagedEntityDefinition |
| |
| // FastLineInventoryAndStatusDataPart2 (Class ID: #436 / 0x01b4) |
| // This ME contains part 3 of the FAST line inventory and status data with attributes specific to |
| // [ITU T G.997.2]. The ONU automatically creates or deletes an instance of this ME upon the |
| // creation or deletion of a PPTP xDSL UNI part 1. |
| // |
| // Relationships |
| // This is one of the status data MEs associated with an xDSL UNI. It is required only if FAST is |
| // supported by the PPTP. The ONU automatically creates or deletes an instance of this ME upon |
| // creation or deletion of a PPTP xDSL UNI part 1 that supports these attributes. |
| // |
| // Attributes |
| // Managed Entity Id |
| // This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is |
| // implicitly linked to an instance of the PPTP xDSL UNI part 1. (R) (mandatory) (2-bytes) |
| // |
| // Date_Time_Stamping Of Last Successful Downstream Fra Operation Stamp_Frads |
| // Date/time-stamping of last successful downstream FRA operation (STAMP-FRAds): This attribute |
| // reports the date/time of the last successful FTU-R initiated FRA execution that has modified the |
| // bits allocation. See clause 7.10.14.5 of [ITUT-G.997.2]. The format of this parameter is as |
| // follows: |
| // |
| // (R) (optional) (7 bytes) |
| // |
| // Date_Time_Stamping Of Last Successful Upstream Fra Operation Stamp_Fraus |
| // Date/time-stamping of last successful upstream FRA operation (STAMP-FRAus): This parameter |
| // reports the date/time of the last successful FTU-O initiated FRA execution that has modified the |
| // bits allocation. See clause 7.10.14.6 of [ITUT-G.997.2]. The format of this parameter is the |
| // same as STAMPTESTNE. (R) (optional) (7 bytes) |
| // |
| // Date_Time_Stamping Of Last Successful Downstream Rpa Operation Stamp_Rpads |
| // Date/time-stamping of last successful downstream RPA operation (STAMP-RPAds): This parameter |
| // reports the date/time of the last successful FTU-R initiated RPA execution that has modified the |
| // bits allocation for the RMC. See clause-7.10.14.7 of [ITU-T G.997.2]. The format of this |
| // parameter is the same as STAMP-TEST-NE. (R) (optional) (7 bytes) |
| // |
| // Date_Time_Stamping Of Last Successful Upstream Rpa Operation Stamp_Rpaus |
| // Date/time-stamping of last successful upstream RPA operation (STAMP-RPAus): This parameter |
| // reports the date/time of the last successful FTU-O initiated RPA execution that has modified the |
| // bits allocation for the RMC. See clause-7.10.14.8 of [ITU-T G.997.2]. The format of this |
| // parameter is the same as STAMP-TEST-NE. (R) (optional) (7 bytes) |
| // |
| // Date_Time_Stamping Of Last Successful Downstream Tiga Operation Stamp_Tiga |
| // Date/time-stamping of last successful downstream TIGA operation (STAMP-TIGA): This parameter |
| // reports the date/time of the last successful FTU-O initiated TIGA execution. See clause |
| // 7.10.14.9 of [ITU-T G.997.2]. The format of this parameter is the same as STAMP-TEST-NE. (R) |
| // (optional) (7 bytes) |
| // |
| type FastLineInventoryAndStatusDataPart2 struct { |
| ManagedEntityDefinition |
| Attributes AttributeValueMap |
| } |
| |
| // Attribute name constants |
| |
| const FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulDownstreamFraOperationStampFrads = "DateTimeStampingOfLastSuccessfulDownstreamFraOperationStampFrads" |
| const FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulUpstreamFraOperationStampFraus = "DateTimeStampingOfLastSuccessfulUpstreamFraOperationStampFraus" |
| const FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulDownstreamRpaOperationStampRpads = "DateTimeStampingOfLastSuccessfulDownstreamRpaOperationStampRpads" |
| const FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulUpstreamRpaOperationStampRpaus = "DateTimeStampingOfLastSuccessfulUpstreamRpaOperationStampRpaus" |
| const FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulDownstreamTigaOperationStampTiga = "DateTimeStampingOfLastSuccessfulDownstreamTigaOperationStampTiga" |
| |
| func init() { |
| fastlineinventoryandstatusdatapart2BME = &ManagedEntityDefinition{ |
| Name: "FastLineInventoryAndStatusDataPart2", |
| ClassID: FastLineInventoryAndStatusDataPart2ClassID, |
| MessageTypes: mapset.NewSetWith( |
| Get, |
| ), |
| AllowedAttributeMask: 0xf800, |
| AttributeDefinitions: AttributeDefinitionMap{ |
| 0: Uint16Field(ManagedEntityID, PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read), false, false, false, 0), |
| 1: MultiByteField(FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulDownstreamFraOperationStampFrads, OctetsAttributeType, 0x8000, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, true, false, 1), |
| 2: MultiByteField(FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulUpstreamFraOperationStampFraus, OctetsAttributeType, 0x4000, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, true, false, 2), |
| 3: MultiByteField(FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulDownstreamRpaOperationStampRpads, OctetsAttributeType, 0x2000, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, true, false, 3), |
| 4: MultiByteField(FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulUpstreamRpaOperationStampRpaus, OctetsAttributeType, 0x1000, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, true, false, 4), |
| 5: MultiByteField(FastLineInventoryAndStatusDataPart2_DateTimeStampingOfLastSuccessfulDownstreamTigaOperationStampTiga, OctetsAttributeType, 0x0800, 7, toOctets("AAAAAAAAAA=="), mapset.NewSetWith(Read), false, true, false, 5), |
| }, |
| Access: CreatedByOnu, |
| Support: UnknownSupport, |
| } |
| } |
| |
| // NewFastLineInventoryAndStatusDataPart2 (class ID 436) creates the basic |
| // Managed Entity definition that is used to validate an ME of this type that |
| // is received from or transmitted to the OMCC. |
| func NewFastLineInventoryAndStatusDataPart2(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| return NewManagedEntity(*fastlineinventoryandstatusdatapart2BME, params...) |
| } |