blob: 00e08276e42fbb513df680f4c7aa5be5065eeb47 [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Chip Boling34ebcb62021-02-02 12:13:58 -060017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// XdslXtuCChannelPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity xDSL xTU-C channel performance monitoring history data
Chip Boling610117d2021-09-09 11:24:34 -050030const XdslXtuCChannelPerformanceMonitoringHistoryDataClassID = ClassID(114) // 0x0072
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var xdslxtucchannelperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// XdslXtuCChannelPerformanceMonitoringHistoryData (Class ID: #114 / 0x0072)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME collects PM data of an xTUC to xTUR channel as seen from the xTU-C. Instances of this ME
36// are created and deleted by the OLT.
37//
38// For a complete discussion of generic PM architecture, refer to clause I.4.
39//
40// Relationships
41// An instance of this ME is associated with an xDSL bearer channel. Several instances may
42// therefore be associated with an xDSL UNI.
43//
44// Attributes
45// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050046// This attribute uniquely identifies each instance of this ME. The two MSBs of the first byte are
47// the bearer channel ID. Excluding the first 2-bits of the first byte, the remaining part of the
48// ME ID is identical to that of this ME's parent PPTP xDSL UNI part 1. (R, setbycreate)
49// (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060050//
51// Interval End Time
Chip Boling610117d2021-09-09 11:24:34 -050052// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060053//
54// Threshold Data 1_2 Id
55// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
56// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
57// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
58//
59// Corrected Blocks
Chip Boling610117d2021-09-09 11:24:34 -050060// This attribute counts blocks received with errors that were corrected on this channel. (R)
Chip Boling6e27b352020-02-14 09:10:01 -060061// (mandatory) (4-bytes)
62//
Chip Boling610117d2021-09-09 11:24:34 -050063// Uncorrected Blocks
64// This attribute counts blocks received with uncorrectable errors on this channel. (R) (mandatory)
Chip Boling6e27b352020-02-14 09:10:01 -060065// (4-bytes)
66//
Chip Boling610117d2021-09-09 11:24:34 -050067// Transmitted Blocks
68// This attribute counts encoded blocks transmitted on this channel. (R) (mandatory) (4-bytes)
69//
70// Received Blocks
71// This attribute counts encoded blocks received on this channel. (R) (mandatory) (4-bytes)
72//
Chip Boling6e27b352020-02-14 09:10:01 -060073// Code Violations
Chip Boling610117d2021-09-09 11:24:34 -050074// This attribute counts CRC-8 anomalies in the bearer channel. (R) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060075//
76// Forward Error Corrections
Chip Boling610117d2021-09-09 11:24:34 -050077// This attribute counts FEC anomalies in the bearer channel. (R) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060078//
79type XdslXtuCChannelPerformanceMonitoringHistoryData struct {
80 ManagedEntityDefinition
81 Attributes AttributeValueMap
82}
83
84func init() {
85 xdslxtucchannelperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
86 Name: "XdslXtuCChannelPerformanceMonitoringHistoryData",
87 ClassID: 114,
88 MessageTypes: mapset.NewSetWith(
89 Create,
90 Delete,
91 Get,
92 Set,
Chip Boling2d51f052021-02-09 09:04:15 -060093 GetCurrentData,
Chip Boling6e27b352020-02-14 09:10:01 -060094 ),
95 AllowedAttributeMask: 0xff00,
96 AttributeDefinitions: AttributeDefinitionMap{
97 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
98 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
99 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
100 3: Uint32Field("CorrectedBlocks", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
101 4: Uint32Field("UncorrectedBlocks", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
102 5: Uint32Field("TransmittedBlocks", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
103 6: Uint32Field("ReceivedBlocks", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
104 7: Uint16Field("CodeViolations", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
105 8: Uint16Field("ForwardErrorCorrections", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
106 },
107 Access: CreatedByOlt,
108 Support: UnknownSupport,
Chip Boling34ebcb62021-02-02 12:13:58 -0600109 Alarms: AlarmMap{
110 0: "Corrected blocks",
111 1: "Uncorrected blocks",
112 2: "Code violations",
113 3: "Forward error corrections",
114 },
Chip Boling6e27b352020-02-14 09:10:01 -0600115 }
116}
117
118// NewXdslXtuCChannelPerformanceMonitoringHistoryData (class ID 114) creates the basic
119// Managed Entity definition that is used to validate an ME of this type that
120// is received from or transmitted to the OMCC.
121func NewXdslXtuCChannelPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
122 return NewManagedEntity(*xdslxtucchannelperformancemonitoringhistorydataBME, params...)