blob: 6585ce30132bb0d378f81d15d8cd382c68da4e7a [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Chip Boling2d51f052021-02-09 09:04:15 -060017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// EfmBondingPortPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity EFM bonding port performance monitoring history data
Chip Boling610117d2021-09-09 11:24:34 -050030const EfmBondingPortPerformanceMonitoringHistoryDataClassID = ClassID(423) // 0x01a7
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var efmbondingportperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// EfmBondingPortPerformanceMonitoringHistoryData (Class ID: #423 / 0x01a7)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME collects PM data as seen at the xTU-C. Instances of this ME are created and deleted by
36// the OLT.
37//
38// Relationships
39// An instance of this ME is associated with an xDSL UNI.
40//
41// Attributes
42// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050043// This attribute uniquely identifies each instance of this ME. The two MSBs of the first byte are
44// the bearer channel ID. Excluding the first 2-bits of the first byte, the remaining part of the
45// ME ID is identical to that of this ME's parent PPTP xDSL UNI part 1. (R, setbycreate)
46// (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060047//
48// Interval End Time
Chip Boling610117d2021-09-09 11:24:34 -050049// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060050//
51// Threshold Data 1_2 Id
52// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
53// that contain PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
54//
55// Rx Frames
Chip Boling610117d2021-09-09 11:24:34 -050056// Number of Ethernet frames received over this port. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060057//
58// Tx Frames
Chip Boling610117d2021-09-09 11:24:34 -050059// Number of Ethernet frames transmitted over this port. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060060//
61// Rx Bytes
Chip Boling610117d2021-09-09 11:24:34 -050062// Number of bytes contained in the Ethernet frames received over this port. (R) (mandatory)
63// (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060064//
65// Tx Bytes
Chip Boling610117d2021-09-09 11:24:34 -050066// Number of bytes contained in the Ethernet frames transmitted over this port. (R) (mandatory)
67// (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060068//
69// Tx Discarded Frames
Chip Boling610117d2021-09-09 11:24:34 -050070// Number of Ethernet frames discarded by the port transmit function. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060071//
72// Tx Discarded Bytes
Chip Boling610117d2021-09-09 11:24:34 -050073// Number of bytes contained in the Ethernet frames discarded by the port transmit function. (R)
74// (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060075//
76type EfmBondingPortPerformanceMonitoringHistoryData struct {
77 ManagedEntityDefinition
78 Attributes AttributeValueMap
79}
80
81func init() {
82 efmbondingportperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
83 Name: "EfmBondingPortPerformanceMonitoringHistoryData",
Chip Boling7a6e8d92021-07-14 15:42:21 -050084 ClassID: 423,
Chip Boling6e27b352020-02-14 09:10:01 -060085 MessageTypes: mapset.NewSetWith(
86 Create,
87 Delete,
88 Get,
89 Set,
Chip Boling2d51f052021-02-09 09:04:15 -060090 GetCurrentData,
Chip Boling6e27b352020-02-14 09:10:01 -060091 ),
92 AllowedAttributeMask: 0xff00,
93 AttributeDefinitions: AttributeDefinitionMap{
94 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
95 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
96 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
97 3: Uint32Field("RxFrames", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
98 4: Uint32Field("TxFrames", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
99 5: Uint32Field("RxBytes", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
100 6: Uint32Field("TxBytes", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
101 7: Uint32Field("TxDiscardedFrames", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
102 8: Uint32Field("TxDiscardedBytes", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
103 },
104 Access: CreatedByOlt,
105 Support: UnknownSupport,
106 }
107}
108
Chip Boling7a6e8d92021-07-14 15:42:21 -0500109// NewEfmBondingPortPerformanceMonitoringHistoryData (class ID 423) creates the basic
Chip Boling6e27b352020-02-14 09:10:01 -0600110// Managed Entity definition that is used to validate an ME of this type that
111// is received from or transmitted to the OMCC.
112func NewEfmBondingPortPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
113 return NewManagedEntity(*efmbondingportperformancemonitoringhistorydataBME, params...)