blob: d2401d843925dc7876348644e9565b55c5f419ab [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
David K. Bainbridgeadf422d2021-04-09 16:06:41 +000017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// EthernetFlowTerminationPointClassID is the 16-bit ID for the OMCI
29// Managed entity Ethernet flow termination point
Chip Boling610117d2021-09-09 11:24:34 -050030const EthernetFlowTerminationPointClassID = ClassID(286) // 0x011e
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var ethernetflowterminationpointBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// EthernetFlowTerminationPoint (Class ID: #286 / 0x011e)
Chip Boling6e27b352020-02-14 09:10:01 -060035// The Ethernet flow TP contains the attributes necessary to originate and terminate Ethernet
36// frames in the ONU. It is appropriate when transporting pseudowire services via layer-2.
37// Instances of this ME are created and deleted by the OLT.
38//
39// Relationships
40// One Ethernet flow TP ME exists for each distinct pseudowire service that is transported via
41// layer 2.
42//
43// Attributes
44// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050045// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
46// implicitly linked to a pseudowire TP ME. (R, setbycreate) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060047//
48// Destination Mac
Chip Boling610117d2021-09-09 11:24:34 -050049// This attribute specifies the destination MAC address of upstream Ethernet frames. (R,-W,
50// setbycreate) (mandatory) (6-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060051//
52// Source Mac
Chip Boling610117d2021-09-09 11:24:34 -050053// This attribute specifies the near-end MAC address. It is established by nonOMCI means (e.g.,
54// factory programmed into ONU flash memory) and is included here for information only. (R)
55// (mandatory) (6-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060056//
57// Tag Policy
Chip Boling610117d2021-09-09 11:24:34 -050058// 0 untagged frame
59//
60// 1 tagged frame
61//
Chip Boling6e27b352020-02-14 09:10:01 -060062// (R,-W, setbycreate) (mandatory) (1-byte)
63//
Chip Boling610117d2021-09-09 11:24:34 -050064// This attribute specifies the tagging policy to be applied to upstream Ethernet frames.
65//
Chip Boling6e27b352020-02-14 09:10:01 -060066// Tci
Chip Boling610117d2021-09-09 11:24:34 -050067// If the tag policy calls for tagging of upstream Ethernet frames, this attribute specifies the
68// tag control information, which includes the VLAN tag, P bits and CFI bit. (R,-W) (optional)
Chip Boling6e27b352020-02-14 09:10:01 -060069// (2-bytes)
70//
71// Loopback
Chip Boling610117d2021-09-09 11:24:34 -050072// This attribute sets the loopback configuration as follows.
73//
74// 0 No loopback
75//
76// 1 Loopback of downstream traffic at MAC client
77//
Chip Boling6e27b352020-02-14 09:10:01 -060078// (R,-W) (mandatory) (1-byte)
79//
80type EthernetFlowTerminationPoint struct {
81 ManagedEntityDefinition
82 Attributes AttributeValueMap
83}
84
85func init() {
86 ethernetflowterminationpointBME = &ManagedEntityDefinition{
87 Name: "EthernetFlowTerminationPoint",
88 ClassID: 286,
89 MessageTypes: mapset.NewSetWith(
90 Create,
91 Delete,
92 Get,
93 Set,
94 ),
95 AllowedAttributeMask: 0xf800,
96 AttributeDefinitions: AttributeDefinitionMap{
97 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
98 1: MultiByteField("DestinationMac", OctetsAttributeType, 0x8000, 6, toOctets("AAAAAAAA"), mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1),
99 2: MultiByteField("SourceMac", OctetsAttributeType, 0x4000, 6, toOctets("AAAAAAAA"), mapset.NewSetWith(Read), false, false, false, 2),
100 3: ByteField("TagPolicy", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 3),
101 4: Uint16Field("Tci", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, Write), false, true, false, 4),
102 5: ByteField("Loopback", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, Write), false, false, false, 5),
103 },
104 Access: CreatedByOlt,
105 Support: UnknownSupport,
106 }
107}
108
109// NewEthernetFlowTerminationPoint (class ID 286) creates the basic
110// Managed Entity definition that is used to validate an ME of this type that
111// is received from or transmitted to the OMCC.
112func NewEthernetFlowTerminationPoint(params ...ParamData) (*ManagedEntity, OmciErrors) {
113 return NewManagedEntity(*ethernetflowterminationpointBME, params...)
114}