blob: c05d9482ee81a5ded20056f96f44fcc69270c83d [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
David K. Bainbridgeadf422d2021-04-09 16:06:41 +000017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// MacBridgeServiceProfileClassID is the 16-bit ID for the OMCI
29// Managed entity MAC bridge service profile
Chip Boling610117d2021-09-09 11:24:34 -050030const MacBridgeServiceProfileClassID = ClassID(45) // 0x002d
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var macbridgeserviceprofileBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// MacBridgeServiceProfile (Class ID: #45 / 0x002d)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME models a MAC bridge in its entirety; any number of ports may be associated with the
36// bridge through pointers to the MAC bridge service profile ME. Instances of this ME are created
37// and deleted by the OLT.
38//
39// Relationships
40// Bridge ports are modelled by MAC bridge port configuration data MEs, any number of which can
41// point to a MAC bridge service profile. The real-time status of the bridge is available from an
42// implicitly linked MAC bridge configuration data ME.
43//
44// Attributes
45// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050046// This attribute uniquely identifies each instance of this ME. The first byte is the slot ID. In
47// an integrated ONU, this value is 0. The second byte is the bridge group ID. (R, setbycreate)
48// (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060049//
50// Spanning Tree Ind
Chip Boling610117d2021-09-09 11:24:34 -050051// The Boolean value true specifies that a spanning tree algorithm is enabled. The value false
52// disables (rapid) spanning tree. (R,-W, setbycreate) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060053//
54// Learning Ind
Chip Boling610117d2021-09-09 11:24:34 -050055// The Boolean value true specifies that bridge learning functions are enabled. The value false
56// disables bridge learning. (R,-W, setbycreate) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060057//
58// Port Bridging Ind
Chip Boling610117d2021-09-09 11:24:34 -050059// The Boolean value true specifies that bridging between UNI ports is enabled. The value false
60// disables local bridging. (R,-W, setbycreate) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060061//
62// Priority
Chip Boling610117d2021-09-09 11:24:34 -050063// This attribute specifies the bridge priority in the range 0..65535. The value of this attribute
64// is copied to the bridge priority attribute of the associated MAC bridge configuration data ME.
65// (R,-W, setbycreate) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060066//
67// Max Age
Chip Boling610117d2021-09-09 11:24:34 -050068// This attribute specifies the maximum age (in 256ths of a second) of received protocol
Chip Boling6e27b352020-02-14 09:10:01 -060069// information before its entry in the spanning tree listing is discarded. The range is 0x0600 to
70// 0x2800 (6..40-s) in accordance with [IEEE-802.1D]. (R,-W, setbycreate) (mandatory) (2-bytes)
71//
72// Hello Time
Chip Boling610117d2021-09-09 11:24:34 -050073// This attribute specifies how often (in 256ths of a second) the bridge advertises its presence
74// via hello packets, while acting as a root or attempting to become a root. The range is 0x0100 to
75// 0x0A00 (1..10-s). (R,-W, setbycreate) (mandatory) (2-bytes)
76//
Chip Boling6e27b352020-02-14 09:10:01 -060077// NOTE - [IEEE 802.1D] specifies the compatibility range for hello time to be 1..2-s.
78//
79// Forward Delay
Chip Boling610117d2021-09-09 11:24:34 -050080// This attribute specifies the forwarding delay (in 256ths of a second) when the bridge acts as
81// the root. The range is 0x0400 to 0x1E00 (4..30-s) in accordance with [IEEE 802.1D]. (R,-W, set-
82// by-create) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060083//
84// Unknown Mac Address Discard
Chip Boling610117d2021-09-09 11:24:34 -050085// The Boolean value true specifies that MAC frames with unknown DAs be discarded. The value false
86// specifies that such frames be forwarded to all allowed ports. (R,-W, setbycreate) (mandatory)
87// (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060088//
89// Mac Learning Depth
Chip Boling610117d2021-09-09 11:24:34 -050090// This attribute specifies the maximum number of UNI MAC addresses to be learned by the bridge.
91// The default value 0 specifies that there is no administratively imposed limit. (R,-W,
92// setbycreate) (optional) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060093//
94// Dynamic Filtering Ageing Time
Chip Boling610117d2021-09-09 11:24:34 -050095// This attribute specifies the age of dynamic filtering entries in the bridge database, after
96// which unrefreshed entries are discarded. In accordance with clause 7.9.2 of [IEEE 802.1D] and
97// clause 8.8.3 of [IEEE 802.1Q], the range is 10..1 000 000-s, with a resolution of 1-s and a
98// default of 300-s. The value 0 specifies that the ONU uses its internal default. (R, W, set-by-
99// create) (optional) (4 bytes)
Chip Boling6e27b352020-02-14 09:10:01 -0600100//
101type MacBridgeServiceProfile struct {
102 ManagedEntityDefinition
103 Attributes AttributeValueMap
104}
105
106func init() {
107 macbridgeserviceprofileBME = &ManagedEntityDefinition{
108 Name: "MacBridgeServiceProfile",
109 ClassID: 45,
110 MessageTypes: mapset.NewSetWith(
111 Create,
112 Delete,
113 Get,
114 Set,
115 ),
116 AllowedAttributeMask: 0xffc0,
117 AttributeDefinitions: AttributeDefinitionMap{
118 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
119 1: ByteField("SpanningTreeInd", EnumerationAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1),
120 2: ByteField("LearningInd", EnumerationAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
121 3: ByteField("PortBridgingInd", EnumerationAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 3),
122 4: Uint16Field("Priority", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 4),
123 5: Uint16Field("MaxAge", UnsignedIntegerAttributeType, 0x0800, 1536, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 5),
124 6: Uint16Field("HelloTime", UnsignedIntegerAttributeType, 0x0400, 256, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 6),
125 7: Uint16Field("ForwardDelay", UnsignedIntegerAttributeType, 0x0200, 1024, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 7),
126 8: ByteField("UnknownMacAddressDiscard", EnumerationAttributeType, 0x0100, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 8),
127 9: ByteField("MacLearningDepth", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 9),
128 10: Uint32Field("DynamicFilteringAgeingTime", UnsignedIntegerAttributeType, 0x0040, 300, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 10),
129 },
130 Access: CreatedByOlt,
131 Support: UnknownSupport,
132 }
133}
134
135// NewMacBridgeServiceProfile (class ID 45) creates the basic
136// Managed Entity definition that is used to validate an ME of this type that
137// is received from or transmitted to the OMCC.
138func NewMacBridgeServiceProfile(params ...ParamData) (*ManagedEntity, OmciErrors) {
139 return NewManagedEntity(*macbridgeserviceprofileBME, params...)
140}