blob: 5e18218499b8cd6b2a712751cc859dd4d6d8109e [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Chip Boling34ebcb62021-02-02 12:13:58 -060017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// PwAtmPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity PW ATM performance monitoring history data
Chip Boling610117d2021-09-09 11:24:34 -050030const PwAtmPerformanceMonitoringHistoryDataClassID = ClassID(338) // 0x0152
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var pwatmperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// PwAtmPerformanceMonitoringHistoryData (Class ID: #338 / 0x0152)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME collects PM data associated with an ATM pseudowire. Instances of this ME are created and
36// deleted by the OLT.
37//
38// For a complete discussion of generic PM architecture, refer to clause I.4.
39//
40// Relationships
41// An instance of this ME is associated with an instance of the PW ATM configuration data ME.
42//
43// Attributes
44// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050045// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
46// implicitly linked to the instance of the PW ATM configuration data ME. (R, setbycreate)
47// (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060048//
49// Interval End Time
Chip Boling610117d2021-09-09 11:24:34 -050050// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060051//
52// Threshold Data 1_2 Id
53// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
54// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
55// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
56//
57// Downstream Missing Packets Counter
Chip Boling610117d2021-09-09 11:24:34 -050058// This attribute counts missing packets, as detected via control word sequence number gaps. (R)
59// (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060060//
61// Downstream Reordered Packets Counter
Chip Boling610117d2021-09-09 11:24:34 -050062// This attribute counts packets detected out of sequence via the control word sequence number, but
63// successfully reordered. Some implementations may not support this feature. (R) (optional)
Chip Boling6e27b352020-02-14 09:10:01 -060064// (4-bytes)
65//
Chip Boling610117d2021-09-09 11:24:34 -050066// Downstream Misordered Packets Counter
67// This attribute counts packets detected out of order via the control word sequence numbers. (R)
68// (mandatory) (4-bytes)
69//
70// Upstream Timeout Packets Counter
71// This attribute counts packets transmitted due to timeout expiration while attempting to collect
72// cells. (R) (mandatory) (4-bytes)
73//
74// Upstream Transmitted Cells Counter
75// This attribute counts transmitted cells. (R) (mandatory) (4-bytes)
76//
Chip Boling6e27b352020-02-14 09:10:01 -060077// Upstream Dropped Cells Counter
Chip Boling610117d2021-09-09 11:24:34 -050078// This attribute counts dropped cells. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060079//
80// Upstream Received Cells Counter
Chip Boling610117d2021-09-09 11:24:34 -050081// This attribute counts received cells. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060082//
83type PwAtmPerformanceMonitoringHistoryData struct {
84 ManagedEntityDefinition
85 Attributes AttributeValueMap
86}
87
88func init() {
89 pwatmperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
90 Name: "PwAtmPerformanceMonitoringHistoryData",
91 ClassID: 338,
92 MessageTypes: mapset.NewSetWith(
93 Create,
94 Delete,
95 Get,
96 Set,
Chip Boling2d51f052021-02-09 09:04:15 -060097 GetCurrentData,
Chip Boling6e27b352020-02-14 09:10:01 -060098 ),
99 AllowedAttributeMask: 0xff80,
100 AttributeDefinitions: AttributeDefinitionMap{
101 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
102 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
103 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
104 3: Uint32Field("DownstreamMissingPacketsCounter", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
105 4: Uint32Field("DownstreamReorderedPacketsCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4),
106 5: Uint32Field("DownstreamMisorderedPacketsCounter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
107 6: Uint32Field("UpstreamTimeoutPacketsCounter", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
108 7: Uint32Field("UpstreamTransmittedCellsCounter", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
109 8: Uint32Field("UpstreamDroppedCellsCounter", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8),
110 9: Uint32Field("UpstreamReceivedCellsCounter", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9),
111 },
112 Access: CreatedByOlt,
113 Support: UnknownSupport,
Chip Boling34ebcb62021-02-02 12:13:58 -0600114 Alarms: AlarmMap{
115 1: "Downstream missing packets",
116 2: "Downstream reordered packets",
117 3: "Downstream timeout packets",
118 4: "Upstream dropped cells",
119 },
Chip Boling6e27b352020-02-14 09:10:01 -0600120 }
121}
122
123// NewPwAtmPerformanceMonitoringHistoryData (class ID 338) creates the basic
124// Managed Entity definition that is used to validate an ME of this type that
125// is received from or transmitted to the OMCC.
126func NewPwAtmPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
127 return NewManagedEntity(*pwatmperformancemonitoringhistorydataBME, params...)
128}