blob: 23949a5d4bce6afac2484a224d94abfc3500a1a0 [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Chip Boling34ebcb62021-02-02 12:13:58 -060017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// SipCallInitiationPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity SIP call initiation performance monitoring history data
Chip Boling610117d2021-09-09 11:24:34 -050030const SipCallInitiationPerformanceMonitoringHistoryDataClassID = ClassID(152) // 0x0098
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var sipcallinitiationperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// SipCallInitiationPerformanceMonitoringHistoryData (Class ID: #152 / 0x0098)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME collects PM data related to call initiations of a VoIP SIP agent. Instances of this ME
36// are created and deleted by the OLT.
37//
38// For a complete discussion of generic PM architecture, refer to clause I.4.
39//
40// Relationships
41// An instance of this ME is associated with an instance of the SIP agent config data or SIP config
42// portal ME.
43//
44// Attributes
45// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050046// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
47// implicitly linked to an instance of the SIP agent config data or the SIP config portal ME. If a
48// nonOMCI configuration method is used for VoIP, there can be only one live ME instance,
49// associated with the SIP config portal, and with ME ID 0. (R, setbycreate) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060050//
51// Interval End Time
Chip Boling610117d2021-09-09 11:24:34 -050052// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060053//
54// Threshold Data 1_2 Id
55// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that
56// contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold
57// data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes)
58//
59// Failed To Connect Counter
Chip Boling610117d2021-09-09 11:24:34 -050060// This attribute counts the number of times that the SIP UA failed to reach/connect its TCP/UDP
61// peer during SIP call initiations. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060062//
63// Failed To Validate Counter
Chip Boling610117d2021-09-09 11:24:34 -050064// This attribute counts the number of times that the SIP UA failed to validate its peer during SIP
Chip Boling6e27b352020-02-14 09:10:01 -060065// call initiations. (R) (mandatory) (4-bytes)
66//
Chip Boling610117d2021-09-09 11:24:34 -050067// Timeout Counter
68// This attribute counts the number of times that the SIP UA timed out during SIP call initiations.
69// (R) (mandatory) (4-bytes)
70//
Chip Boling6e27b352020-02-14 09:10:01 -060071// Failure Received Counter
Chip Boling610117d2021-09-09 11:24:34 -050072// This attribute counts the number of times that the SIP UA received a failure error code during
73// SIP call initiations. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060074//
75// Failed To Authenticate Counter
Chip Boling610117d2021-09-09 11:24:34 -050076// This attribute counts the number of times that the SIP UA failed to authenticate itself during
77// SIP call initiations. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060078//
79type SipCallInitiationPerformanceMonitoringHistoryData struct {
80 ManagedEntityDefinition
81 Attributes AttributeValueMap
82}
83
84func init() {
85 sipcallinitiationperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
86 Name: "SipCallInitiationPerformanceMonitoringHistoryData",
87 ClassID: 152,
88 MessageTypes: mapset.NewSetWith(
89 Create,
90 Delete,
91 Get,
92 Set,
Chip Boling2d51f052021-02-09 09:04:15 -060093 GetCurrentData,
Chip Boling6e27b352020-02-14 09:10:01 -060094 ),
95 AllowedAttributeMask: 0xfe00,
96 AttributeDefinitions: AttributeDefinitionMap{
97 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
98 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
99 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
100 3: Uint32Field("FailedToConnectCounter", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
101 4: Uint32Field("FailedToValidateCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4),
102 5: Uint32Field("TimeoutCounter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5),
103 6: Uint32Field("FailureReceivedCounter", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6),
104 7: Uint32Field("FailedToAuthenticateCounter", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7),
105 },
106 Access: CreatedByOlt,
107 Support: UnknownSupport,
Chip Boling34ebcb62021-02-02 12:13:58 -0600108 Alarms: AlarmMap{
109 0: "SIP call PM failed connect",
110 1: "SIP call PM failed to validate",
111 2: "SIP call PM timeout",
112 3: "SIP call PM failure error code received",
113 4: "SIP call PM failed to authenticate",
114 },
Chip Boling6e27b352020-02-14 09:10:01 -0600115 }
116}
117
118// NewSipCallInitiationPerformanceMonitoringHistoryData (class ID 152) creates the basic
119// Managed Entity definition that is used to validate an ME of this type that
120// is received from or transmitted to the OMCC.
121func NewSipCallInitiationPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
122 return NewManagedEntity(*sipcallinitiationperformancemonitoringhistorydataBME, params...)