Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 1 | /* |
| 2 | * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 3 | * Copyright 2020-present Open Networking Foundation |
| 4 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 5 | * Licensed under the Apache License, Version 2.0 (the "License"); |
| 6 | * you may not use this file except in compliance with the License. |
| 7 | * You may obtain a copy of the License at |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 8 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 9 | * http://www.apache.org/licenses/LICENSE-2.0 |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 10 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 11 | * Unless required by applicable law or agreed to in writing, software |
| 12 | * distributed under the License is distributed on an "AS IS" BASIS, |
| 13 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 14 | * See the License for the specific language governing permissions and |
| 15 | * limitations under the License. |
| 16 | */ |
Chip Boling | 34ebcb6 | 2021-02-02 12:13:58 -0600 | [diff] [blame] | 17 | /* |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 18 | * NOTE: This file was generated, manual edits will be overwritten! |
| 19 | * |
| 20 | * Generated by 'goCodeGenerator.py': |
| 21 | * https://github.com/cboling/OMCI-parser/README.md |
| 22 | */ |
| 23 | |
| 24 | package generated |
| 25 | |
| 26 | import "github.com/deckarep/golang-set" |
| 27 | |
| 28 | // EthernetPerformanceMonitoringHistoryData2ClassID is the 16-bit ID for the OMCI |
| 29 | // Managed entity Ethernet performance monitoring history data 2 |
| 30 | const EthernetPerformanceMonitoringHistoryData2ClassID ClassID = ClassID(89) |
| 31 | |
| 32 | var ethernetperformancemonitoringhistorydata2BME *ManagedEntityDefinition |
| 33 | |
| 34 | // EthernetPerformanceMonitoringHistoryData2 (class ID #89) |
| 35 | // This ME collects additional PM data for a physical Ethernet interface. Instances of this ME are |
| 36 | // created and deleted by the OLT. |
| 37 | // |
| 38 | // For a complete discussion of generic PM architecture, refer to clause I.4. |
| 39 | // |
| 40 | // Relationships |
| 41 | // An instance of this Ethernet PM history data 2 ME is associated with an instance of the PPTP |
| 42 | // Ethernet UNI. |
| 43 | // |
| 44 | // Attributes |
| 45 | // Managed Entity Id |
| 46 | // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| 47 | // identical ID, this ME is implicitly linked to an instance of the PPTP Ethernet UNI. (R, |
| 48 | // setbycreate) (mandatory) (2-bytes) |
| 49 | // |
| 50 | // Interval End Time |
| 51 | // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| 52 | // (mandatory) (1-byte) |
| 53 | // |
| 54 | // Threshold Data 1_2 Id |
| 55 | // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 ME that |
| 56 | // contains PM threshold values. Since no threshold value attribute number exceeds 7, a threshold |
| 57 | // data 2 ME is optional. (R,-W, setbycreate) (mandatory) (2-bytes) |
| 58 | // |
| 59 | // Pppoe Filtered Frame Counter |
| 60 | // PPPoE filtered frame counter: This attribute counts the number of frames discarded due to PPPoE |
| 61 | // filtering. (R) (mandatory) (4-bytes) |
| 62 | // |
| 63 | type EthernetPerformanceMonitoringHistoryData2 struct { |
| 64 | ManagedEntityDefinition |
| 65 | Attributes AttributeValueMap |
| 66 | } |
| 67 | |
| 68 | func init() { |
| 69 | ethernetperformancemonitoringhistorydata2BME = &ManagedEntityDefinition{ |
| 70 | Name: "EthernetPerformanceMonitoringHistoryData2", |
| 71 | ClassID: 89, |
| 72 | MessageTypes: mapset.NewSetWith( |
| 73 | Create, |
| 74 | Delete, |
| 75 | Get, |
| 76 | Set, |
Chip Boling | 2d51f05 | 2021-02-09 09:04:15 -0600 | [diff] [blame] | 77 | GetCurrentData, |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 78 | ), |
| 79 | AllowedAttributeMask: 0xe000, |
| 80 | AttributeDefinitions: AttributeDefinitionMap{ |
| 81 | 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 82 | 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 83 | 2: Uint16Field("ThresholdData12Id", PointerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 84 | 3: Uint32Field("PppoeFilteredFrameCounter", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 85 | }, |
| 86 | Access: CreatedByOlt, |
| 87 | Support: UnknownSupport, |
Chip Boling | 34ebcb6 | 2021-02-02 12:13:58 -0600 | [diff] [blame] | 88 | Alarms: AlarmMap{ |
| 89 | 0: "PPPoE filtered frame counter", |
| 90 | }, |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 91 | } |
| 92 | } |
| 93 | |
| 94 | // NewEthernetPerformanceMonitoringHistoryData2 (class ID 89) creates the basic |
| 95 | // Managed Entity definition that is used to validate an ME of this type that |
| 96 | // is received from or transmitted to the OMCC. |
| 97 | func NewEthernetPerformanceMonitoringHistoryData2(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| 98 | return NewManagedEntity(*ethernetperformancemonitoringhistorydata2BME, params...) |
| 99 | } |