Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 1 | /* |
| 2 | * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 3 | * Copyright 2020-present Open Networking Foundation |
| 4 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 5 | * Licensed under the Apache License, Version 2.0 (the "License"); |
| 6 | * you may not use this file except in compliance with the License. |
| 7 | * You may obtain a copy of the License at |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 8 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 9 | * http://www.apache.org/licenses/LICENSE-2.0 |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 10 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 11 | * Unless required by applicable law or agreed to in writing, software |
| 12 | * distributed under the License is distributed on an "AS IS" BASIS, |
| 13 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 14 | * See the License for the specific language governing permissions and |
| 15 | * limitations under the License. |
| 16 | */ |
Chip Boling | 34ebcb6 | 2021-02-02 12:13:58 -0600 | [diff] [blame] | 17 | /* |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 18 | * NOTE: This file was generated, manual edits will be overwritten! |
| 19 | * |
| 20 | * Generated by 'goCodeGenerator.py': |
| 21 | * https://github.com/cboling/OMCI-parser/README.md |
| 22 | */ |
| 23 | |
| 24 | package generated |
| 25 | |
| 26 | import "github.com/deckarep/golang-set" |
| 27 | |
| 28 | // TwdmChannelPloamPerformanceMonitoringHistoryDataPart2ClassID is the 16-bit ID for the OMCI |
| 29 | // Managed entity TWDM channel PLOAM performance monitoring history data part 2 |
| 30 | const TwdmChannelPloamPerformanceMonitoringHistoryDataPart2ClassID ClassID = ClassID(447) |
| 31 | |
| 32 | var twdmchannelploamperformancemonitoringhistorydatapart2BME *ManagedEntityDefinition |
| 33 | |
| 34 | // TwdmChannelPloamPerformanceMonitoringHistoryDataPart2 (class ID #447) |
| 35 | // This ME collects additional PLOAM-related PM data associated with the slot/circuit pack, hosting |
| 36 | // one or more ANI-G MEs, for a specific TWDM channel. Instances of this ME are created and deleted |
| 37 | // by the OLT. |
| 38 | // |
| 39 | // The downstream PLOAM message counts of this ME include only the received PLOAM messages |
| 40 | // pertaining to the given ONU, i.e.: |
| 41 | // |
| 42 | // - unicast PLOAM messages, addressed by ONU-ID; |
| 43 | // |
| 44 | // - broadcast PLOAM messages, addressed by serial number; |
| 45 | // |
| 46 | // - broadcast PLOAM messages, addressed to all ONUs on the PON. |
| 47 | // |
| 48 | // All these counters are characterized as optional in clause 14 of [ITU-T- G.989.3]. |
| 49 | // |
| 50 | // For a complete discussion of generic PM architecture, refer to clause I.4. |
| 51 | // |
| 52 | // Relationships |
| 53 | // An instance of this ME is associated with an instance of TWDM channel ME. |
| 54 | // |
| 55 | // Attributes |
| 56 | // Managed Entity Id |
| 57 | // Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an |
| 58 | // identical ID, this ME is implicitly linked to an instance of the TWDM channel ME. (R, |
| 59 | // setbycreate) (mandatory) (2-bytes) |
| 60 | // |
| 61 | // Interval End Time |
| 62 | // Interval end time: This attribute identifies the most recently finished 15-min interval. (R) |
| 63 | // (mandatory) (1-byte) |
| 64 | // |
| 65 | // Threshold Data 1_2 Id |
| 66 | // Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs |
| 67 | // that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes) |
| 68 | // |
| 69 | // System_Profile Message Count |
| 70 | // System_Profile message count: The counter of received System_Profile PLOAM messages. (R) |
| 71 | // (mandatory) (4-byte) |
| 72 | // |
| 73 | // Channel_Profile Message Count |
| 74 | // Channel_Profile message count: The counter of received Channel_Profile PLOAM messages. (R) |
| 75 | // (mandatory) (4-byte) |
| 76 | // |
| 77 | // Burst_Profile Message Count |
| 78 | // Burst_Profile message count: The counter of received Burst_Profile PLOAM messages. (R) |
| 79 | // (mandatory) (4-byte) |
| 80 | // |
| 81 | // Assign_Onu_Id Message Count |
| 82 | // Assign_ONU-ID message count: The counter of received Assign_ONU-ID PLOAM messages. (R) |
| 83 | // (mandatory) (4-byte) |
| 84 | // |
| 85 | // Unsatisfied Adjust_Tx_Wavelength Requests |
| 86 | // Unsatisfied Adjust_Tx_Wavelength requests: The counter of Adjust_Tx_Wavelength requests not |
| 87 | // applied or partially applied due to target US wavelength being out of Tx tuning range. (R) |
| 88 | // (mandatory) (4-byte) |
| 89 | // |
| 90 | // Deactivate_Onu_Id Message Count |
| 91 | // Deactivate_ONU-ID message count: The counter of received Deactivate_ONU-ID PLOAM messages. (R) |
| 92 | // (mandatory) (4-byte) |
| 93 | // |
| 94 | // Disable_Serial_Number Message Count |
| 95 | // Disable_Serial_Number message count: The counter of received Disable_Serial_Number PLOAM |
| 96 | // messages. (R) (mandatory) (4-byte) |
| 97 | // |
| 98 | // Request_Registration Message Count |
| 99 | // Request_Registration message count: The counter of received Request_Registration PLOAM messages. |
| 100 | // (R) (mandatory) (4-byte) |
| 101 | // |
| 102 | // Assign_Alloc_Id Message Count |
| 103 | // Assign_Alloc-ID message count: The counter of received Assign_Alloc-ID PLOAM messages. (R) |
| 104 | // (mandatory) (4-byte) |
| 105 | // |
| 106 | // Key_Control Message Count |
| 107 | // Key_Control message count: The counter of received Key_Control PLOAM messages. (R) (mandatory) |
| 108 | // (4-byte) |
| 109 | // |
| 110 | // Sleep_Allow Message Count |
| 111 | // Sleep_Allow message count: The counter of received Sleep_Allow PLOAM messages. (R) (mandatory) |
| 112 | // (4-byte) |
| 113 | // |
| 114 | // Tuning_Control_Request Message Count |
| 115 | // Tuning_Control/Request message count: The counter of received Tuning_Control PLOAM messages with |
| 116 | // Request operation code. (R) (mandatory) (4-byte) |
| 117 | // |
| 118 | // Tuning_Control_Complete_D Message Count |
| 119 | // Tuning_Control/Complete_d message count: The counter of received Tuning_Control PLOAM messages |
| 120 | // with Complete_d operation code. (R) (mandatory) (4-byte) |
| 121 | // |
| 122 | // Calibration_Request Message Count |
| 123 | // Calibration_Request message count: The counter of received Calibration_Request PLOAM messages. |
| 124 | // (R) (mandatory) (4-byte) |
| 125 | // |
| 126 | type TwdmChannelPloamPerformanceMonitoringHistoryDataPart2 struct { |
| 127 | ManagedEntityDefinition |
| 128 | Attributes AttributeValueMap |
| 129 | } |
| 130 | |
| 131 | func init() { |
| 132 | twdmchannelploamperformancemonitoringhistorydatapart2BME = &ManagedEntityDefinition{ |
| 133 | Name: "TwdmChannelPloamPerformanceMonitoringHistoryDataPart2", |
| 134 | ClassID: 447, |
| 135 | MessageTypes: mapset.NewSetWith( |
| 136 | Create, |
| 137 | Delete, |
| 138 | Get, |
| 139 | GetCurrentData, |
| 140 | Set, |
| 141 | ), |
| 142 | AllowedAttributeMask: 0xffff, |
| 143 | AttributeDefinitions: AttributeDefinitionMap{ |
| 144 | 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 145 | 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1), |
| 146 | 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 147 | 3: Uint32Field("SystemProfileMessageCount", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3), |
| 148 | 4: Uint32Field("ChannelProfileMessageCount", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, false, false, 4), |
| 149 | 5: Uint32Field("BurstProfileMessageCount", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, false, false, 5), |
| 150 | 6: Uint32Field("AssignOnuIdMessageCount", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, false, false, 6), |
| 151 | 7: Uint32Field("UnsatisfiedAdjustTxWavelengthRequests", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, false, false, 7), |
| 152 | 8: Uint32Field("DeactivateOnuIdMessageCount", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, false, false, 8), |
| 153 | 9: Uint32Field("DisableSerialNumberMessageCount", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, false, false, 9), |
| 154 | 10: Uint32Field("RequestRegistrationMessageCount", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, false, false, 10), |
| 155 | 11: Uint32Field("AssignAllocIdMessageCount", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, false, false, 11), |
| 156 | 12: Uint32Field("KeyControlMessageCount", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, false, false, 12), |
| 157 | 13: Uint32Field("SleepAllowMessageCount", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, false, false, 13), |
| 158 | 14: Uint32Field("TuningControlRequestMessageCount", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, false, false, 14), |
| 159 | 15: Uint32Field("TuningControlCompleteDMessageCount", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, false, false, 15), |
| 160 | 16: Uint32Field("CalibrationRequestMessageCount", CounterAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, false, false, 16), |
| 161 | }, |
| 162 | Access: CreatedByOlt, |
| 163 | Support: UnknownSupport, |
Chip Boling | 34ebcb6 | 2021-02-02 12:13:58 -0600 | [diff] [blame] | 164 | Alarms: AlarmMap{ |
| 165 | 0: "Unsatisfied Adjust_Tx_Wavelength requests", |
| 166 | }, |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 167 | } |
| 168 | } |
| 169 | |
| 170 | // NewTwdmChannelPloamPerformanceMonitoringHistoryDataPart2 (class ID 447) creates the basic |
| 171 | // Managed Entity definition that is used to validate an ME of this type that |
| 172 | // is received from or transmitted to the OMCC. |
| 173 | func NewTwdmChannelPloamPerformanceMonitoringHistoryDataPart2(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| 174 | return NewManagedEntity(*twdmchannelploamperformancemonitoringhistorydatapart2BME, params...) |
| 175 | } |