blob: 0c2d5546982ecf4107e0b374b5a4d0c7c74c2c17 [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
David K. Bainbridgeadf422d2021-04-09 16:06:41 +000017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// FastXtuCPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity FAST xTU-C performance monitoring history data
Chip Boling610117d2021-09-09 11:24:34 -050030const FastXtuCPerformanceMonitoringHistoryDataClassID = ClassID(437) // 0x01b5
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var fastxtucperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// FastXtuCPerformanceMonitoringHistoryData (Class ID: #437 / 0x01b5)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME collects PM data on the xTU C to xTU R path as seen from the xTU-C. Instances of this ME
36// are created and deleted by the OLT.
37//
38// Relationships
39// An instance of this ME is associated with an xDSL UNI.
40//
41// Attributes
42// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050043// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
44// implicitly linked to an instance of the PPTP xDSL UNI part 1. (R, set-by-create) (mandatory) (2
45// bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060046//
47// Interval End Time
Chip Boling610117d2021-09-09 11:24:34 -050048// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1 byte)
Chip Boling6e27b352020-02-14 09:10:01 -060049//
50// Threshold Data 1_2 Id
51// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
52// that contain PM threshold values. (R, W, set-by-create) (mandatory) (2 bytes)
53//
54// Successful Fra Counter
Chip Boling610117d2021-09-09 11:24:34 -050055// This attribute counts the successful FRA primitives (success_FRA). The successful FRA primitive
56// (success_FRA) is defined in clause 11.3.1.6 of [ITU-T G.9701]. See clause 7.7.22 of [ITU-T
57// G.997.2]. (R) (mandatory) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060058//
59// Successful Rpa Counter
Chip Boling610117d2021-09-09 11:24:34 -050060// This attribute counts the successful RPA primitives (success_RPA). The successful RPA primitive
61// (success_RPA) is defined in clause 11.3.1.6 of [ITU-T G.9701]. See clause 7.7.23 of [ITU-T
62// G.997.2] (R) (optional) (4 bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060063//
64// Successful Tiga Counter
Chip Boling610117d2021-09-09 11:24:34 -050065// This attribute counts the successful TIGA primitives (success_TIGA). The successful TIGA
66// primitive (success_TIGA) is defined in clause 11.3.1.6 of [ITU-T G.9701]. Reported only with the
67// near-end measured time, invalid data flag and timestamp. See clause 7.7.24 of [ITUT-G.997.2] (R)
68// (optional) (4 bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060069//
70type FastXtuCPerformanceMonitoringHistoryData struct {
71 ManagedEntityDefinition
72 Attributes AttributeValueMap
73}
74
75func init() {
76 fastxtucperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
77 Name: "FastXtuCPerformanceMonitoringHistoryData",
78 ClassID: 437,
79 MessageTypes: mapset.NewSetWith(
80 Create,
81 Delete,
82 Get,
83 Set,
84 ),
85 AllowedAttributeMask: 0xf800,
86 AttributeDefinitions: AttributeDefinitionMap{
87 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
88 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
89 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
90 3: Uint32Field("SuccessfulFraCounter", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, false, false, 3),
91 4: Uint32Field("SuccessfulRpaCounter", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4),
92 5: Uint32Field("SuccessfulTigaCounter", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5),
93 },
94 Access: CreatedByOlt,
95 Support: UnknownSupport,
96 }
97}
98
99// NewFastXtuCPerformanceMonitoringHistoryData (class ID 437) creates the basic
100// Managed Entity definition that is used to validate an ME of this type that
101// is received from or transmitted to the OMCC.
102func NewFastXtuCPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
103 return NewManagedEntity(*fastxtucperformancemonitoringhistorydataBME, params...)
104}