blob: c69d00b5c7330821dba874ddb0c3e82cd3e9e376 [file] [log] [blame]
Chip Boling6e27b352020-02-14 09:10:01 -06001/*
2 * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
Andrea Campanella7167ebb2020-02-24 09:56:38 +01003 * Copyright 2020-present Open Networking Foundation
4
Chip Boling6e27b352020-02-14 09:10:01 -06005 * Licensed under the Apache License, Version 2.0 (the "License");
6 * you may not use this file except in compliance with the License.
7 * You may obtain a copy of the License at
Andrea Campanella7167ebb2020-02-24 09:56:38 +01008
Chip Boling6e27b352020-02-14 09:10:01 -06009 * http://www.apache.org/licenses/LICENSE-2.0
Andrea Campanella7167ebb2020-02-24 09:56:38 +010010
Chip Boling6e27b352020-02-14 09:10:01 -060011 * Unless required by applicable law or agreed to in writing, software
12 * distributed under the License is distributed on an "AS IS" BASIS,
13 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14 * See the License for the specific language governing permissions and
15 * limitations under the License.
16 */
Chip Boling34ebcb62021-02-02 12:13:58 -060017/*
Chip Boling6e27b352020-02-14 09:10:01 -060018 * NOTE: This file was generated, manual edits will be overwritten!
19 *
20 * Generated by 'goCodeGenerator.py':
21 * https://github.com/cboling/OMCI-parser/README.md
22 */
23
24package generated
25
26import "github.com/deckarep/golang-set"
27
28// MocaEthernetPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
29// Managed entity MoCA Ethernet performance monitoring history data
Chip Boling610117d2021-09-09 11:24:34 -050030const MocaEthernetPerformanceMonitoringHistoryDataClassID = ClassID(163) // 0x00a3
Chip Boling6e27b352020-02-14 09:10:01 -060031
32var mocaethernetperformancemonitoringhistorydataBME *ManagedEntityDefinition
33
Chip Boling610117d2021-09-09 11:24:34 -050034// MocaEthernetPerformanceMonitoringHistoryData (Class ID: #163 / 0x00a3)
Chip Boling6e27b352020-02-14 09:10:01 -060035// This ME collects PM data for an MoCA Ethernet interface. Instances of this ME are created and
36// deleted by the OLT.
37//
38// For a complete discussion of generic PM architecture, refer to clause I.4.
39//
40// Relationships
41// An instance of this ME is associated with an instance of the PPTP MoCA UNI ME.
42//
43// Attributes
44// Managed Entity Id
Chip Boling610117d2021-09-09 11:24:34 -050045// This attribute uniquely identifies each instance of this ME. Through an identical ID, this ME is
46// implicitly linked to an instance of the PPTP MoCA UNI. (R, setbycreate) (mandatory) (2-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060047//
48// Interval End Time
Chip Boling610117d2021-09-09 11:24:34 -050049// This attribute identifies the most recently finished 15-min interval. (R) (mandatory) (1-byte)
Chip Boling6e27b352020-02-14 09:10:01 -060050//
51// Threshold Data 1_2 Id
52// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
53// that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
54//
Chip Boling610117d2021-09-09 11:24:34 -050055// Incoming PM refers to upstream traffic received on the UNI; outgoing PM refers to downstream
56// traffic transmitted on the UNI.
57//
Chip Boling6e27b352020-02-14 09:10:01 -060058// Incoming Unicast Packets
Chip Boling610117d2021-09-09 11:24:34 -050059// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060060//
61// Incoming Discarded Packets
Chip Boling610117d2021-09-09 11:24:34 -050062// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060063//
64// Incoming Errored Packets
Chip Boling610117d2021-09-09 11:24:34 -050065// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060066//
67// Incoming Unknown Packets
Chip Boling610117d2021-09-09 11:24:34 -050068// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060069//
70// Incoming Multicast Packets
Chip Boling610117d2021-09-09 11:24:34 -050071// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060072//
73// Incoming Broadcast Packets
Chip Boling610117d2021-09-09 11:24:34 -050074// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060075//
76// Incoming Octets
Chip Boling610117d2021-09-09 11:24:34 -050077// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060078//
79// Outgoing Unicast Packets
Chip Boling610117d2021-09-09 11:24:34 -050080// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060081//
82// Outgoing Discarded Packets
Chip Boling610117d2021-09-09 11:24:34 -050083// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060084//
85// Outgoing Errored Packets
Chip Boling610117d2021-09-09 11:24:34 -050086// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060087//
88// Outgoing Unknown Packets
Chip Boling610117d2021-09-09 11:24:34 -050089// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060090//
91// Outgoing Multicast Packets
Chip Boling610117d2021-09-09 11:24:34 -050092// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060093//
94// Outgoing Broadcast Packets
Chip Boling610117d2021-09-09 11:24:34 -050095// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060096//
97// Outgoing Octets
Chip Boling610117d2021-09-09 11:24:34 -050098// (R) (optional) (4-bytes)
Chip Boling6e27b352020-02-14 09:10:01 -060099//
100type MocaEthernetPerformanceMonitoringHistoryData struct {
101 ManagedEntityDefinition
102 Attributes AttributeValueMap
103}
104
105func init() {
106 mocaethernetperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
107 Name: "MocaEthernetPerformanceMonitoringHistoryData",
108 ClassID: 163,
109 MessageTypes: mapset.NewSetWith(
110 Create,
111 Delete,
112 Get,
113 Set,
114 ),
115 AllowedAttributeMask: 0xffff,
116 AttributeDefinitions: AttributeDefinitionMap{
117 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0),
118 1: ByteField("IntervalEndTime", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read), false, false, false, 1),
119 2: Uint16Field("ThresholdData12Id", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2),
120 3: Uint32Field("IncomingUnicastPackets", CounterAttributeType, 0x2000, 0, mapset.NewSetWith(Read), false, true, false, 3),
121 4: Uint32Field("IncomingDiscardedPackets", CounterAttributeType, 0x1000, 0, mapset.NewSetWith(Read), false, true, false, 4),
122 5: Uint32Field("IncomingErroredPackets", CounterAttributeType, 0x0800, 0, mapset.NewSetWith(Read), false, true, false, 5),
123 6: Uint32Field("IncomingUnknownPackets", CounterAttributeType, 0x0400, 0, mapset.NewSetWith(Read), false, true, false, 6),
124 7: Uint32Field("IncomingMulticastPackets", CounterAttributeType, 0x0200, 0, mapset.NewSetWith(Read), false, true, false, 7),
125 8: Uint32Field("IncomingBroadcastPackets", CounterAttributeType, 0x0100, 0, mapset.NewSetWith(Read), false, true, false, 8),
126 9: Uint32Field("IncomingOctets", CounterAttributeType, 0x0080, 0, mapset.NewSetWith(Read), false, true, false, 9),
127 10: Uint32Field("OutgoingUnicastPackets", CounterAttributeType, 0x0040, 0, mapset.NewSetWith(Read), false, true, false, 10),
128 11: Uint32Field("OutgoingDiscardedPackets", CounterAttributeType, 0x0020, 0, mapset.NewSetWith(Read), false, true, false, 11),
129 12: Uint32Field("OutgoingErroredPackets", CounterAttributeType, 0x0010, 0, mapset.NewSetWith(Read), false, true, false, 12),
130 13: Uint32Field("OutgoingUnknownPackets", CounterAttributeType, 0x0008, 0, mapset.NewSetWith(Read), false, true, false, 13),
131 14: Uint32Field("OutgoingMulticastPackets", CounterAttributeType, 0x0004, 0, mapset.NewSetWith(Read), false, true, false, 14),
132 15: Uint32Field("OutgoingBroadcastPackets", CounterAttributeType, 0x0002, 0, mapset.NewSetWith(Read), false, true, false, 15),
133 16: Uint32Field("OutgoingOctets", CounterAttributeType, 0x0001, 0, mapset.NewSetWith(Read), false, true, false, 16),
134 },
135 Access: CreatedByOlt,
136 Support: UnknownSupport,
Chip Boling34ebcb62021-02-02 12:13:58 -0600137 Alarms: AlarmMap{
138 0: "Incoming unicast packets",
139 1: "Incoming discarded packets",
140 2: "Incoming errored packets",
141 3: "Incoming unknown packets",
142 4: "Incoming multicast packets",
143 5: "Incoming broadcast packets",
144 6: "Incoming octets",
145 7: "Outgoing unicast packets",
146 8: "Outgoing discarded packets",
147 9: "Outgoing errored packets",
148 10: "Outgoing unknown packets",
149 11: "Outgoing multicast packets",
150 12: "Outgoing broadcast packets",
151 13: "Outgoing octets",
152 },
Chip Boling6e27b352020-02-14 09:10:01 -0600153 }
154}
155
156// NewMocaEthernetPerformanceMonitoringHistoryData (class ID 163) creates the basic
157// Managed Entity definition that is used to validate an ME of this type that
158// is received from or transmitted to the OMCC.
159func NewMocaEthernetPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
160 return NewManagedEntity(*mocaethernetperformancemonitoringhistorydataBME, params...)
161}