Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 1 | /* |
| 2 | * Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net) |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 3 | * Copyright 2020-present Open Networking Foundation |
| 4 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 5 | * Licensed under the Apache License, Version 2.0 (the "License"); |
| 6 | * you may not use this file except in compliance with the License. |
| 7 | * You may obtain a copy of the License at |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 8 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 9 | * http://www.apache.org/licenses/LICENSE-2.0 |
Andrea Campanella | 7167ebb | 2020-02-24 09:56:38 +0100 | [diff] [blame] | 10 | |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 11 | * Unless required by applicable law or agreed to in writing, software |
| 12 | * distributed under the License is distributed on an "AS IS" BASIS, |
| 13 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 14 | * See the License for the specific language governing permissions and |
| 15 | * limitations under the License. |
| 16 | */ |
David K. Bainbridge | adf422d | 2021-04-09 16:06:41 +0000 | [diff] [blame] | 17 | /* |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 18 | * NOTE: This file was generated, manual edits will be overwritten! |
| 19 | * |
| 20 | * Generated by 'goCodeGenerator.py': |
| 21 | * https://github.com/cboling/OMCI-parser/README.md |
| 22 | */ |
| 23 | |
| 24 | package generated |
| 25 | |
| 26 | import "github.com/deckarep/golang-set" |
| 27 | |
| 28 | // MplsPseudowireTerminationPointClassID is the 16-bit ID for the OMCI |
| 29 | // Managed entity MPLS pseudowire termination point |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 30 | const MplsPseudowireTerminationPointClassID = ClassID(333) // 0x014d |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 31 | |
| 32 | var mplspseudowireterminationpointBME *ManagedEntityDefinition |
| 33 | |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 34 | // MplsPseudowireTerminationPoint (Class ID: #333 / 0x014d) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 35 | // This ME contains the configuration data of a pseudowire whose underlying transport method is |
| 36 | // MPLS. Instances of this ME are created and deleted by the OLT. |
| 37 | // |
| 38 | // Relationships |
| 39 | // Zero or one instance of this ME is associated with each instance of the pseudowire TP ME. |
| 40 | // |
| 41 | // Attributes |
| 42 | // Managed Entity Id |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 43 | // This attribute uniquely identifies each instance of this ME. (R, setbycreate)-(mandatory) (2 |
| 44 | // bytes) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 45 | // |
| 46 | // Tp Type |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 47 | // This attribute specifies the type of ANI-side TP associated with this-ME. |
| 48 | // |
| 49 | // 1 Ethernet flow termination point |
| 50 | // |
| 51 | // 2 GEM IW TP |
| 52 | // |
| 53 | // 3 TCP/UDP config data |
| 54 | // |
| 55 | // 4 MPLS pseudowire termination point |
| 56 | // |
| 57 | // NOTE - If this instance of the MPLS PW TP is pointed to by another instance of the MPLS PW TP |
| 58 | // (i.e., whose TP type-= 4), this instance represents a tunnelled MPLS flow, and the following |
| 59 | // attributes are not meaningful: MPLS PW direction; MPLS PW uplink label; MPLS PW downlink label; |
| 60 | // and MPLS PW TC. These attributes should be set to the proper number of 0x00 bytes by the OLT and |
| 61 | // ignored by the ONU. |
| 62 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 63 | // (R, W, setbycreate) (mandatory) (1 byte) |
| 64 | // |
| 65 | // Tp Pointer |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 66 | // This attribute points to the instance of the TP associated with this MPLS PW TP. The type of the |
| 67 | // associated TP is determined by the TP type attribute. (R, W, setbycreate) (mandatory) (2 bytes) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 68 | // |
| 69 | // Mpls Label Indicator |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 70 | // This attribute specifies the MPLS label stacking situation. |
| 71 | // |
| 72 | // 0 Single MPLS labelled |
| 73 | // |
| 74 | // 1 Double MPLS labelled |
| 75 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 76 | // (R, W, setbycreate) (mandatory) (1 byte) |
| 77 | // |
| 78 | // Mpls Pw Direction |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 79 | // This attribute specifies the inner MPLS direction. |
| 80 | // |
| 81 | // 0 Upstream only |
| 82 | // |
| 83 | // 1 Downstream only |
| 84 | // |
| 85 | // 2 Bidirectional |
| 86 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 87 | // (R, W, setbycreate) (mandatory) (1 byte) |
| 88 | // |
| 89 | // Mpls Pw Uplink Label |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 90 | // This attribute specifies the label of the inner MPLS pseudowire upstream. The attribute is not |
| 91 | // meaningful for unidirectional downstream PWs. (R, W, setbycreate) (mandatory) (4 bytes) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 92 | // |
| 93 | // Mpls Pw Downlink Label |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 94 | // This attribute specifies the label of the inner MPLS pseudowire downstream. The attribute is not |
| 95 | // meaningful for unidirectional upstream PWs. (R, W, setbycreate) (mandatory) (4 bytes) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 96 | // |
| 97 | // Mpls Pw Tc |
| 98 | // NOTE 1 - The TC field was previously known as EXP. Refer to [bIETF-RFC-5462]. |
| 99 | // |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 100 | // This attribute specifies the inner MPLS TC value in the upstream direction. The attribute is not |
| 101 | // meaningful for unidirectional downstream PWs. (R, W, setbycreate) (mandatory) (1 byte) |
| 102 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 103 | // Mpls Tunnel Direction |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 104 | // This attribute specifies the direction of the (outer) MPLS tunnel. |
| 105 | // |
| 106 | // 0 Upstream only |
| 107 | // |
| 108 | // 1 Downstream only |
| 109 | // |
| 110 | // 2 Bidirectional |
| 111 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 112 | // (R, W, setbycreate) (mandatory for double-labelled case) (1 byte) |
| 113 | // |
| 114 | // Mpls Tunnel Uplink Label |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 115 | // This attribute specifies the (outer) label for the upstream MPLS tunnel. If the MPLS tunnel is |
| 116 | // downstream only, this attribute should be set to 0. (R, W, setbycreate) (mandatory for double- |
| 117 | // labelled case) (4 bytes) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 118 | // |
| 119 | // Mpls Tunnel Downlink Label |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 120 | // This attribute specifies the (outer) label for the downstream MPLS tunnel. If the MPLS tunnel is |
| 121 | // upstream only, this attribute should be set to 0. (R, W, setbycreate) (mandatory for double- |
| 122 | // labelled case) (4 bytes) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 123 | // |
| 124 | // Mpls Tunnel Tc |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 125 | // This attribute specifies the TC value of the upstream MPLS tunnel. If the MPLS tunnel is |
| 126 | // downstream only, this attribute should be set to 0. (R, W, setbycreate) (mandatory for double |
| 127 | // MPLS labelled case) (1 byte) |
| 128 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 129 | // NOTE 2 - The TC field was previously known as EXP. Refer to [bIETF-RFC-5462]. |
| 130 | // |
| 131 | // Pseudowire Type |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 132 | // This attribute specifies the emulated service to be carried over this PW. The values are from |
| 133 | // [IETF RFC 4446]. |
| 134 | // |
| 135 | // 2 ATM AAL5 SDU VCC transport |
| 136 | // |
| 137 | // 3 ATM transparent cell transport |
| 138 | // |
| 139 | // 5 Ethernet |
| 140 | // |
| 141 | // 9 ATM n-to-one VCC cell transport |
| 142 | // |
| 143 | // 10 ATM n-to-one VPC cell transport |
| 144 | // |
| 145 | // 12 ATM one-to-one VCC cell mode |
| 146 | // |
| 147 | // 13 ATM one-to-one VPC cell mode |
| 148 | // |
| 149 | // 14 ATM AAL5 PDU VCC transport |
| 150 | // |
| 151 | // All other values are reserved. |
| 152 | // |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 153 | // (R, W, setbycreate) (mandatory) (2 bytes) |
| 154 | // |
| 155 | // Pseudowire Control Word Preference |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 156 | // When set to true, this Boolean attribute specifies that a control word is to be sent with each |
| 157 | // packet. Some PW types mandate the use of a control word in any event. In such cases, the value |
| 158 | // configured for this attribute has no effect on the presence of the control word. (R, W, |
| 159 | // setbycreate) (optional) (1 byte) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 160 | // |
| 161 | // Administrative State |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 162 | // This attribute locks (1) and unlocks (0) the functions performed by the MPLS pseudowire TP. |
| 163 | // Administrative state is further described in clause-A.1.6. (R,-W) (optional) (1-byte) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 164 | // |
| 165 | // Operational State |
Chip Boling | 610117d | 2021-09-09 11:24:34 -0500 | [diff] [blame] | 166 | // This attribute reports whether the ME is currently capable of performing its function. Valid |
| 167 | // values are enabled (0) and disabled (1). (R) (optional) (1-byte) |
Chip Boling | 6e27b35 | 2020-02-14 09:10:01 -0600 | [diff] [blame] | 168 | // |
| 169 | type MplsPseudowireTerminationPoint struct { |
| 170 | ManagedEntityDefinition |
| 171 | Attributes AttributeValueMap |
| 172 | } |
| 173 | |
| 174 | func init() { |
| 175 | mplspseudowireterminationpointBME = &ManagedEntityDefinition{ |
| 176 | Name: "MplsPseudowireTerminationPoint", |
| 177 | ClassID: 333, |
| 178 | MessageTypes: mapset.NewSetWith( |
| 179 | Create, |
| 180 | Delete, |
| 181 | Get, |
| 182 | Set, |
| 183 | ), |
| 184 | AllowedAttributeMask: 0xfffe, |
| 185 | AttributeDefinitions: AttributeDefinitionMap{ |
| 186 | 0: Uint16Field("ManagedEntityId", PointerAttributeType, 0x0000, 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, 0), |
| 187 | 1: ByteField("TpType", UnsignedIntegerAttributeType, 0x8000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 1), |
| 188 | 2: Uint16Field("TpPointer", UnsignedIntegerAttributeType, 0x4000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 2), |
| 189 | 3: ByteField("MplsLabelIndicator", UnsignedIntegerAttributeType, 0x2000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 3), |
| 190 | 4: ByteField("MplsPwDirection", UnsignedIntegerAttributeType, 0x1000, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 4), |
| 191 | 5: Uint32Field("MplsPwUplinkLabel", UnsignedIntegerAttributeType, 0x0800, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 5), |
| 192 | 6: Uint32Field("MplsPwDownlinkLabel", UnsignedIntegerAttributeType, 0x0400, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 6), |
| 193 | 7: ByteField("MplsPwTc", UnsignedIntegerAttributeType, 0x0200, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 7), |
| 194 | 8: ByteField("MplsTunnelDirection", UnsignedIntegerAttributeType, 0x0100, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 8), |
| 195 | 9: Uint32Field("MplsTunnelUplinkLabel", UnsignedIntegerAttributeType, 0x0080, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 9), |
| 196 | 10: Uint32Field("MplsTunnelDownlinkLabel", UnsignedIntegerAttributeType, 0x0040, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 10), |
| 197 | 11: ByteField("MplsTunnelTc", UnsignedIntegerAttributeType, 0x0020, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 11), |
| 198 | 12: Uint16Field("PseudowireType", UnsignedIntegerAttributeType, 0x0010, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, 12), |
| 199 | 13: ByteField("PseudowireControlWordPreference", UnsignedIntegerAttributeType, 0x0008, 0, mapset.NewSetWith(Read, SetByCreate, Write), false, true, false, 13), |
| 200 | 14: ByteField("AdministrativeState", UnsignedIntegerAttributeType, 0x0004, 0, mapset.NewSetWith(Read, Write), false, true, false, 14), |
| 201 | 15: ByteField("OperationalState", UnsignedIntegerAttributeType, 0x0002, 0, mapset.NewSetWith(Read), true, true, false, 15), |
| 202 | }, |
| 203 | Access: CreatedByOlt, |
| 204 | Support: UnknownSupport, |
| 205 | } |
| 206 | } |
| 207 | |
| 208 | // NewMplsPseudowireTerminationPoint (class ID 333) creates the basic |
| 209 | // Managed Entity definition that is used to validate an ME of this type that |
| 210 | // is received from or transmitted to the OMCC. |
| 211 | func NewMplsPseudowireTerminationPoint(params ...ParamData) (*ManagedEntity, OmciErrors) { |
| 212 | return NewManagedEntity(*mplspseudowireterminationpointBME, params...) |
| 213 | } |