| /* |
| * Copyright 2018-present Open Networking Foundation |
| |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| package core |
| |
| import ( |
| "context" |
| "encoding/hex" |
| "encoding/json" |
| "errors" |
| "fmt" |
| "github.com/cenkalti/backoff/v3" |
| "github.com/opencord/openolt-scale-tester/config" |
| "github.com/opencord/voltha-lib-go/v2/pkg/db/kvstore" |
| "github.com/opencord/voltha-lib-go/v2/pkg/log" |
| "github.com/opencord/voltha-lib-go/v2/pkg/techprofile" |
| oop "github.com/opencord/voltha-protos/v2/go/openolt" |
| "google.golang.org/grpc" |
| "google.golang.org/grpc/codes" |
| "google.golang.org/grpc/status" |
| "io" |
| "io/ioutil" |
| "os" |
| "strconv" |
| "sync" |
| "syscall" |
| "time" |
| ) |
| |
| const ( |
| ReasonOk = "OK" |
| TechProfileKVPath = "service/voltha/technology_profiles/%s/%d" // service/voltha/technology_profiles/xgspon/<tech_profile_tableID> |
| DTWorkFlow = "DT" |
| ) |
| |
| type OnuDeviceKey struct { |
| onuID uint32 |
| ponInfID uint32 |
| } |
| |
| type OpenOltManager struct { |
| ipPort string |
| deviceInfo *oop.DeviceInfo |
| OnuDeviceMap map[OnuDeviceKey]*OnuDevice `json:"onuDeviceMap"` |
| TechProfile map[uint32]*techprofile.TechProfileIf |
| clientConn *grpc.ClientConn |
| openOltClient oop.OpenoltClient |
| testConfig *config.OpenOltScaleTesterConfig |
| rsrMgr *OpenOltResourceMgr |
| lockRsrAlloc sync.RWMutex |
| } |
| |
| func init() { |
| _, _ = log.AddPackage(log.JSON, log.DebugLevel, nil) |
| } |
| |
| func NewOpenOltManager(ipPort string) *OpenOltManager { |
| log.Infow("initialized openolt manager with ipPort", log.Fields{"ipPort": ipPort}) |
| return &OpenOltManager{ |
| ipPort: ipPort, |
| OnuDeviceMap: make(map[OnuDeviceKey]*OnuDevice), |
| lockRsrAlloc: sync.RWMutex{}, |
| } |
| } |
| |
| func (om *OpenOltManager) readAndLoadTPsToEtcd() { |
| var byteValue []byte |
| var err error |
| // Verify that etcd is up before starting the application. |
| etcdIpPort := "http://" + om.testConfig.KVStoreHost + ":" + strconv.Itoa(om.testConfig.KVStorePort) |
| client, err := kvstore.NewEtcdClient(etcdIpPort, 5) |
| if err != nil || client == nil { |
| log.Fatal("error-initializing-etcd-client") |
| return |
| } |
| |
| // Load TPs to etcd for each of the specified tech-profiles |
| for _, tpID := range om.testConfig.TpIDList { |
| // Below should translate to something like "/app/ATT-64.json" |
| // The TP file should exist. |
| tpFilePath := "/app/" + om.testConfig.WorkflowName + "-" + strconv.Itoa(tpID) + ".json" |
| // Open our jsonFile |
| jsonFile, err := os.Open(tpFilePath) |
| // if we os.Open returns an error then handle it |
| if err != nil { |
| log.Fatalw("could-not-find-tech-profile", log.Fields{"err": err, "tpFile": tpFilePath}) |
| } |
| log.Debugw("tp-file-opened-successfully", log.Fields{"tpFile": tpFilePath}) |
| |
| // read our opened json file as a byte array. |
| if byteValue, err = ioutil.ReadAll(jsonFile); err != nil { |
| log.Fatalw("could-not-read-tp-file", log.Fields{"err": err, "tpFile": tpFilePath}) |
| } |
| |
| var tp techprofile.TechProfile |
| |
| if err = json.Unmarshal(byteValue, &tp); err != nil { |
| log.Fatalw("could-not-unmarshal-tp", log.Fields{"err": err, "tpFile": tpFilePath}) |
| } else { |
| log.Infow("tp-read-from-file", log.Fields{"tp": tp, "tpFile": tpFilePath}) |
| } |
| kvPath := fmt.Sprintf(TechProfileKVPath, om.deviceInfo.Technology, tpID) |
| tpJson, err := json.Marshal(tp) |
| err = client.Put(kvPath, tpJson, 2) |
| if err != nil { |
| log.Fatalw("tp-put-to-etcd-failed", log.Fields{"tpPath": kvPath, "err": err}) |
| } |
| // verify the PUT succeeded. |
| kvResult, err := client.Get(kvPath, 2) |
| if kvResult == nil { |
| log.Fatal("tp-not-found-on-kv-after-load", log.Fields{"key": kvPath, "err": err}) |
| } else { |
| var KvTpIns techprofile.TechProfile |
| var resPtr = &KvTpIns |
| if value, err := kvstore.ToByte(kvResult.Value); err == nil { |
| if err = json.Unmarshal(value, resPtr); err != nil { |
| log.Fatal("error-unmarshal-kv-result", log.Fields{"err": err, "key": kvPath, "value": value}) |
| } else { |
| log.Infow("verified-ok-that-tp-load-was-good", log.Fields{"tpID": tpID, "kvPath": kvPath}) |
| _ = jsonFile.Close() |
| continue |
| } |
| } |
| } |
| } |
| } |
| |
| func (om *OpenOltManager) Start(testConfig *config.OpenOltScaleTesterConfig) error { |
| var err error |
| om.testConfig = testConfig |
| |
| // Establish gRPC connection with the device |
| if om.clientConn, err = grpc.Dial(om.ipPort, grpc.WithInsecure(), grpc.WithBlock()); err != nil { |
| log.Errorw("Failed to dial device", log.Fields{"ipPort": om.ipPort, "err": err}) |
| return err |
| } |
| om.openOltClient = oop.NewOpenoltClient(om.clientConn) |
| |
| // Populate Device Info |
| if deviceInfo, err := om.populateDeviceInfo(); err != nil { |
| log.Error("error fetching device info", log.Fields{"err": err, "deviceInfo": deviceInfo}) |
| return err |
| } |
| |
| // Read and load TPs to etcd. |
| om.readAndLoadTPsToEtcd() |
| |
| log.Info("etcd-up-and-running--tp-loaded-successfully") |
| |
| if om.rsrMgr = NewResourceMgr("ABCD", om.testConfig.KVStoreHost+":"+strconv.Itoa(om.testConfig.KVStorePort), |
| "etcd", "openolt", om.deviceInfo); om.rsrMgr == nil { |
| log.Error("Error while instantiating resource manager") |
| return errors.New("instantiating resource manager failed") |
| } |
| |
| om.TechProfile = make(map[uint32]*techprofile.TechProfileIf) |
| if err = om.populateTechProfilePerPonPort(); err != nil { |
| log.Error("Error while populating tech profile mgr\n") |
| return errors.New("error-loading-tech-profile-per-ponPort") |
| } |
| |
| // Start reading indications |
| go om.readIndications() |
| |
| // Provision OLT NNI Trap flows as needed by the Workflow |
| if err = ProvisionNniTrapFlow(om.openOltClient, om.testConfig, om.rsrMgr); err != nil { |
| log.Error("failed-to-add-nni-trap-flow", log.Fields{"err": err}) |
| } |
| |
| // Provision ONUs one by one |
| go om.provisionONUs() |
| |
| return nil |
| |
| } |
| |
| func (om *OpenOltManager) populateDeviceInfo() (*oop.DeviceInfo, error) { |
| var err error |
| |
| if om.deviceInfo, err = om.openOltClient.GetDeviceInfo(context.Background(), new(oop.Empty)); err != nil { |
| log.Errorw("Failed to fetch device info", log.Fields{"err": err}) |
| return nil, err |
| } |
| |
| if om.deviceInfo == nil { |
| log.Errorw("Device info is nil", log.Fields{}) |
| return nil, errors.New("failed to get device info from OLT") |
| } |
| |
| log.Debugw("Fetched device info", log.Fields{"deviceInfo": om.deviceInfo}) |
| |
| return om.deviceInfo, nil |
| } |
| |
| func (om *OpenOltManager) provisionONUs() { |
| var numOfONUsPerPon uint |
| var i, j, onuID uint32 |
| var err error |
| oltChan := make(chan bool) |
| numOfONUsPerPon = om.testConfig.NumOfOnu / uint(om.deviceInfo.PonPorts) |
| if oddONUs := om.testConfig.NumOfOnu % uint(om.deviceInfo.PonPorts); oddONUs > 0 { |
| log.Warnw("Odd number ONUs left out of provisioning", log.Fields{"oddONUs": oddONUs}) |
| } |
| totalOnusToProvision := numOfONUsPerPon * uint(om.deviceInfo.PonPorts) |
| log.Infow("***** all-onu-provision-started ******", |
| log.Fields{"totalNumOnus": totalOnusToProvision, |
| "numOfOnusPerPon": numOfONUsPerPon, |
| "numOfPons": om.deviceInfo.PonPorts}) |
| for i = 0; i < om.deviceInfo.PonPorts; i++ { |
| for j = 0; j < uint32(numOfONUsPerPon); j++ { |
| // TODO: More work with ONU provisioning |
| om.lockRsrAlloc.Lock() |
| sn := GenerateNextONUSerialNumber() |
| om.lockRsrAlloc.Unlock() |
| log.Debugw("provisioning onu", log.Fields{"onuID": j, "ponPort": i, "serialNum": sn}) |
| if onuID, err = om.rsrMgr.GetONUID(i); err != nil { |
| log.Errorw("error getting onu id", log.Fields{"err": err}) |
| continue |
| } |
| log.Infow("onu-provision-started-from-olt-manager", log.Fields{"onuId": onuID, "ponIntf": i}) |
| go om.activateONU(i, onuID, sn, om.stringifySerialNumber(sn), oltChan) |
| // Wait for complete ONU provision to succeed, including provisioning the subscriber |
| <-oltChan |
| log.Infow("onu-provision-completed-from-olt-manager", log.Fields{"onuId": onuID, "ponIntf": i}) |
| |
| // Sleep for configured time before provisioning next ONU |
| time.Sleep(time.Duration(om.testConfig.TimeIntervalBetweenSubs)) |
| } |
| } |
| log.Info("******** all-onu-provisioning-completed *******") |
| |
| // TODO: We need to dump the results at the end. But below json marshall does not work |
| // We will need custom Marshal function. |
| /* |
| e, err := json.Marshal(om) |
| if err != nil { |
| fmt.Println(err) |
| return |
| } |
| fmt.Println(string(e)) |
| */ |
| |
| // Stop the process once the job is done |
| _ = syscall.Kill(syscall.Getpid(), syscall.SIGINT) |
| } |
| |
| func (om *OpenOltManager) activateONU(intfID uint32, onuID uint32, serialNum *oop.SerialNumber, serialNumber string, oltCh chan bool) { |
| log.Debugw("activate-onu", log.Fields{"intfID": intfID, "onuID": onuID, "serialNum": serialNum, "serialNumber": serialNumber}) |
| // TODO: need resource manager |
| var pir uint32 = 1000000 |
| var onuDevice = OnuDevice{ |
| SerialNum: serialNumber, |
| OnuID: onuID, |
| PonIntf: intfID, |
| openOltClient: om.openOltClient, |
| testConfig: om.testConfig, |
| rsrMgr: om.rsrMgr, |
| } |
| var err error |
| onuDeviceKey := OnuDeviceKey{onuID: onuID, ponInfID: intfID} |
| Onu := oop.Onu{IntfId: intfID, OnuId: onuID, SerialNumber: serialNum, Pir: pir} |
| now := time.Now() |
| nanos := now.UnixNano() |
| milliStart := nanos / 1000000 |
| onuDevice.OnuProvisionStartTime = time.Unix(0, nanos) |
| if _, err = om.openOltClient.ActivateOnu(context.Background(), &Onu); err != nil { |
| st, _ := status.FromError(err) |
| if st.Code() == codes.AlreadyExists { |
| log.Debug("ONU activation is in progress", log.Fields{"SerialNumber": serialNumber}) |
| oltCh <- false |
| } else { |
| nanos = now.UnixNano() |
| milliEnd := nanos / 1000000 |
| onuDevice.OnuProvisionEndTime = time.Unix(0, nanos) |
| onuDevice.OnuProvisionDurationInMs = milliEnd - milliStart |
| log.Errorw("activate-onu-failed", log.Fields{"Onu": Onu, "err ": err}) |
| onuDevice.Reason = err.Error() |
| oltCh <- false |
| } |
| } else { |
| nanos = now.UnixNano() |
| milliEnd := nanos / 1000000 |
| onuDevice.OnuProvisionEndTime = time.Unix(0, nanos) |
| onuDevice.OnuProvisionDurationInMs = milliEnd - milliStart |
| onuDevice.Reason = ReasonOk |
| log.Infow("activated-onu", log.Fields{"SerialNumber": serialNumber}) |
| } |
| |
| om.OnuDeviceMap[onuDeviceKey] = &onuDevice |
| |
| // If ONU activation was success provision the ONU |
| if err == nil { |
| // start provisioning the ONU |
| go om.OnuDeviceMap[onuDeviceKey].Start(oltCh) |
| } |
| } |
| |
| func (om *OpenOltManager) stringifySerialNumber(serialNum *oop.SerialNumber) string { |
| if serialNum != nil { |
| return string(serialNum.VendorId) + om.stringifyVendorSpecific(serialNum.VendorSpecific) |
| } |
| return "" |
| } |
| |
| func (om *OpenOltManager) stringifyVendorSpecific(vendorSpecific []byte) string { |
| tmp := fmt.Sprintf("%x", (uint32(vendorSpecific[0])>>4)&0x0f) + |
| fmt.Sprintf("%x", uint32(vendorSpecific[0]&0x0f)) + |
| fmt.Sprintf("%x", (uint32(vendorSpecific[1])>>4)&0x0f) + |
| fmt.Sprintf("%x", (uint32(vendorSpecific[1]))&0x0f) + |
| fmt.Sprintf("%x", (uint32(vendorSpecific[2])>>4)&0x0f) + |
| fmt.Sprintf("%x", (uint32(vendorSpecific[2]))&0x0f) + |
| fmt.Sprintf("%x", (uint32(vendorSpecific[3])>>4)&0x0f) + |
| fmt.Sprintf("%x", (uint32(vendorSpecific[3]))&0x0f) |
| return tmp |
| } |
| |
| // readIndications to read the indications from the OLT device |
| func (om *OpenOltManager) readIndications() { |
| defer log.Errorw("Indications ended", log.Fields{}) |
| indications, err := om.openOltClient.EnableIndication(context.Background(), new(oop.Empty)) |
| if err != nil { |
| log.Errorw("Failed to read indications", log.Fields{"err": err}) |
| return |
| } |
| if indications == nil { |
| log.Errorw("Indications is nil", log.Fields{}) |
| return |
| } |
| |
| // Create an exponential backoff around re-enabling indications. The |
| // maximum elapsed time for the back off is set to 0 so that we will |
| // continue to retry. The max interval defaults to 1m, but is set |
| // here for code clarity |
| indicationBackoff := backoff.NewExponentialBackOff() |
| indicationBackoff.MaxElapsedTime = 0 |
| indicationBackoff.MaxInterval = 1 * time.Minute |
| for { |
| indication, err := indications.Recv() |
| if err == io.EOF { |
| log.Infow("EOF for indications", log.Fields{"err": err}) |
| // Use an exponential back off to prevent getting into a tight loop |
| duration := indicationBackoff.NextBackOff() |
| if duration == backoff.Stop { |
| // If we reach a maximum then warn and reset the backoff |
| // timer and keep attempting. |
| log.Warnw("Maximum indication backoff reached, resetting backoff timer", |
| log.Fields{"max_indication_backoff": indicationBackoff.MaxElapsedTime}) |
| indicationBackoff.Reset() |
| } |
| time.Sleep(indicationBackoff.NextBackOff()) |
| indications, err = om.openOltClient.EnableIndication(context.Background(), new(oop.Empty)) |
| if err != nil { |
| log.Errorw("Failed to read indications", log.Fields{"err": err}) |
| return |
| } |
| continue |
| } |
| if err != nil { |
| log.Infow("Failed to read from indications", log.Fields{"err": err}) |
| break |
| } |
| // Reset backoff if we have a successful receive |
| indicationBackoff.Reset() |
| om.handleIndication(indication) |
| |
| } |
| } |
| |
| func (om *OpenOltManager) handleIndication(indication *oop.Indication) { |
| switch indication.Data.(type) { |
| case *oop.Indication_OltInd: |
| log.Info("received olt indication") |
| case *oop.Indication_IntfInd: |
| intfInd := indication.GetIntfInd() |
| log.Infow("Received interface indication ", log.Fields{"InterfaceInd": intfInd}) |
| case *oop.Indication_IntfOperInd: |
| intfOperInd := indication.GetIntfOperInd() |
| if intfOperInd.GetType() == "nni" { |
| log.Info("received interface oper indication for nni port") |
| } else if intfOperInd.GetType() == "pon" { |
| log.Info("received interface oper indication for pon port") |
| } |
| /* |
| case *oop.Indication_OnuDiscInd: |
| onuDiscInd := indication.GetOnuDiscInd() |
| log.Infow("Received Onu discovery indication ", log.Fields{"OnuDiscInd": onuDiscInd}) |
| */ |
| case *oop.Indication_OnuInd: |
| onuInd := indication.GetOnuInd() |
| log.Infow("Received Onu indication ", log.Fields{"OnuInd": onuInd}) |
| case *oop.Indication_OmciInd: |
| omciInd := indication.GetOmciInd() |
| log.Debugw("Received Omci indication ", log.Fields{"IntfId": omciInd.IntfId, "OnuId": omciInd.OnuId, "pkt": hex.EncodeToString(omciInd.Pkt)}) |
| case *oop.Indication_PktInd: |
| pktInd := indication.GetPktInd() |
| log.Infow("Received pakcet indication ", log.Fields{"PktInd": pktInd}) |
| /* |
| case *oop.Indication_PortStats: |
| portStats := indication.GetPortStats() |
| log.Infow("Received port stats", log.Fields{"portStats": portStats}) |
| case *oop.Indication_FlowStats: |
| flowStats := indication.GetFlowStats() |
| log.Infow("Received flow stats", log.Fields{"FlowStats": flowStats}) |
| */ |
| case *oop.Indication_AlarmInd: |
| alarmInd := indication.GetAlarmInd() |
| log.Infow("Received alarm indication ", log.Fields{"AlarmInd": alarmInd}) |
| } |
| } |
| |
| func (om *OpenOltManager) populateTechProfilePerPonPort() error { |
| var tpCount int |
| for _, techRange := range om.deviceInfo.Ranges { |
| for _, intfID := range techRange.IntfIds { |
| om.TechProfile[intfID] = &(om.rsrMgr.ResourceMgrs[intfID].TechProfileMgr) |
| tpCount++ |
| log.Debugw("Init tech profile done", log.Fields{"intfID": intfID}) |
| } |
| } |
| //Make sure we have as many tech_profiles as there are pon ports on the device |
| if tpCount != int(om.deviceInfo.GetPonPorts()) { |
| log.Errorw("Error while populating techprofile", |
| log.Fields{"numofTech": tpCount, "numPonPorts": om.deviceInfo.GetPonPorts()}) |
| return errors.New("error while populating techprofile mgrs") |
| } |
| log.Infow("Populated techprofile for ponports successfully", |
| log.Fields{"numofTech": tpCount, "numPonPorts": om.deviceInfo.GetPonPorts()}) |
| return nil |
| } |