Girish Gowdra | 6450343 | 2020-01-07 10:59:10 +0530 | [diff] [blame] | 1 | /* |
| 2 | * Copyright 2018-present Open Networking Foundation |
| 3 | |
| 4 | * Licensed under the Apache License, Version 2.0 (the "License"); |
| 5 | * you may not use this file except in compliance with the License. |
| 6 | * You may obtain a copy of the License at |
| 7 | |
| 8 | * http://www.apache.org/licenses/LICENSE-2.0 |
| 9 | |
| 10 | * Unless required by applicable law or agreed to in writing, software |
| 11 | * distributed under the License is distributed on an "AS IS" BASIS, |
| 12 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| 13 | * See the License for the specific language governing permissions and |
| 14 | * limitations under the License. |
| 15 | */ |
| 16 | |
| 17 | package core |
| 18 | |
| 19 | import ( |
| 20 | "context" |
| 21 | "encoding/hex" |
| 22 | "encoding/json" |
| 23 | "errors" |
| 24 | "fmt" |
| 25 | "github.com/cenkalti/backoff/v3" |
| 26 | "github.com/opencord/openolt-scale-tester/config" |
| 27 | "github.com/opencord/voltha-lib-go/v2/pkg/db/kvstore" |
| 28 | "github.com/opencord/voltha-lib-go/v2/pkg/log" |
| 29 | "github.com/opencord/voltha-lib-go/v2/pkg/techprofile" |
| 30 | oop "github.com/opencord/voltha-protos/v2/go/openolt" |
| 31 | "google.golang.org/grpc" |
| 32 | "google.golang.org/grpc/codes" |
| 33 | "google.golang.org/grpc/status" |
| 34 | "io" |
| 35 | "io/ioutil" |
| 36 | "os" |
| 37 | "strconv" |
| 38 | "sync" |
| 39 | "syscall" |
| 40 | "time" |
| 41 | ) |
| 42 | |
| 43 | const ( |
| 44 | ReasonOk = "OK" |
| 45 | TechProfileKVPath = "service/voltha/technology_profiles/%s/%d" // service/voltha/technology_profiles/xgspon/<tech_profile_tableID> |
| 46 | ) |
| 47 | |
| 48 | type OnuDeviceKey struct { |
| 49 | onuID uint32 |
| 50 | ponInfID uint32 |
| 51 | } |
| 52 | |
| 53 | type OpenOltManager struct { |
| 54 | ipPort string |
| 55 | deviceInfo *oop.DeviceInfo |
| 56 | OnuDeviceMap map[OnuDeviceKey]*OnuDevice `json:"onuDeviceMap"` |
| 57 | TechProfile map[uint32]*techprofile.TechProfileIf |
| 58 | clientConn *grpc.ClientConn |
| 59 | openOltClient oop.OpenoltClient |
| 60 | testConfig *config.OpenOltScaleTesterConfig |
| 61 | rsrMgr *OpenOltResourceMgr |
| 62 | lockRsrAlloc sync.RWMutex |
| 63 | } |
| 64 | |
| 65 | func init() { |
| 66 | _, _ = log.AddPackage(log.JSON, log.DebugLevel, nil) |
| 67 | } |
| 68 | |
| 69 | func NewOpenOltManager(ipPort string) *OpenOltManager { |
| 70 | log.Infow("initialized openolt manager with ipPort", log.Fields{"ipPort": ipPort}) |
| 71 | return &OpenOltManager{ |
| 72 | ipPort: ipPort, |
| 73 | OnuDeviceMap: make(map[OnuDeviceKey]*OnuDevice), |
| 74 | lockRsrAlloc: sync.RWMutex{}, |
| 75 | } |
| 76 | } |
| 77 | |
| 78 | func (om *OpenOltManager) readAndLoadTPsToEtcd() { |
| 79 | var byteValue []byte |
| 80 | var err error |
| 81 | // Verify that etcd is up before starting the application. |
| 82 | etcdIpPort := "http://" + om.testConfig.KVStoreHost + ":" + strconv.Itoa(om.testConfig.KVStorePort) |
| 83 | client, err := kvstore.NewEtcdClient(etcdIpPort, 5) |
| 84 | if err != nil || client == nil { |
| 85 | log.Fatal("error-initializing-etcd-client") |
| 86 | return |
| 87 | } |
| 88 | |
| 89 | // Load TPs to etcd for each of the specified tech-profiles |
| 90 | for _, tpID := range om.testConfig.TpIDList { |
| 91 | // Below should translate to something like "/app/ATT-64.json" |
| 92 | // The TP file should exist. |
| 93 | tpFilePath := "/app/" + om.testConfig.WorkflowName + "-" + strconv.Itoa(tpID) + ".json" |
| 94 | // Open our jsonFile |
| 95 | jsonFile, err := os.Open(tpFilePath) |
| 96 | // if we os.Open returns an error then handle it |
| 97 | if err != nil { |
| 98 | log.Fatalw("could-not-find-tech-profile", log.Fields{"err": err, "tpFile": tpFilePath}) |
| 99 | } |
| 100 | log.Debugw("tp-file-opened-successfully", log.Fields{"tpFile": tpFilePath}) |
| 101 | |
| 102 | // read our opened json file as a byte array. |
| 103 | if byteValue, err = ioutil.ReadAll(jsonFile); err != nil { |
| 104 | log.Fatalw("could-not-read-tp-file", log.Fields{"err": err, "tpFile": tpFilePath}) |
| 105 | } |
| 106 | |
| 107 | var tp techprofile.TechProfile |
| 108 | |
| 109 | if err = json.Unmarshal(byteValue, &tp); err != nil { |
| 110 | log.Fatalw("could-not-unmarshal-tp", log.Fields{"err": err, "tpFile": tpFilePath}) |
| 111 | } else { |
| 112 | log.Infow("tp-read-from-file", log.Fields{"tp": tp, "tpFile": tpFilePath}) |
| 113 | } |
| 114 | kvPath := fmt.Sprintf(TechProfileKVPath, om.deviceInfo.Technology, tpID) |
| 115 | tpJson, err := json.Marshal(tp) |
| 116 | err = client.Put(kvPath, tpJson, 2) |
| 117 | if err != nil { |
| 118 | log.Fatalw("tp-put-to-etcd-failed", log.Fields{"tpPath": kvPath, "err": err}) |
| 119 | } |
| 120 | // verify the PUT succeeded. |
| 121 | kvResult, err := client.Get(kvPath, 2) |
| 122 | if kvResult == nil { |
| 123 | log.Fatal("tp-not-found-on-kv-after-load", log.Fields{"key": kvPath, "err": err}) |
| 124 | } else { |
| 125 | var KvTpIns techprofile.TechProfile |
| 126 | var resPtr = &KvTpIns |
| 127 | if value, err := kvstore.ToByte(kvResult.Value); err == nil { |
| 128 | if err = json.Unmarshal(value, resPtr); err != nil { |
| 129 | log.Fatal("error-unmarshal-kv-result", log.Fields{"err": err, "key": kvPath, "value": value}) |
| 130 | } else { |
| 131 | log.Infow("verified-ok-that-tp-load-was-good", log.Fields{"tpID": tpID, "kvPath": kvPath}) |
| 132 | _ = jsonFile.Close() |
| 133 | continue |
| 134 | } |
| 135 | } |
| 136 | } |
| 137 | } |
| 138 | } |
| 139 | |
| 140 | func (om *OpenOltManager) Start(testConfig *config.OpenOltScaleTesterConfig) error { |
| 141 | var err error |
| 142 | om.testConfig = testConfig |
| 143 | |
| 144 | // Establish gRPC connection with the device |
| 145 | if om.clientConn, err = grpc.Dial(om.ipPort, grpc.WithInsecure(), grpc.WithBlock()); err != nil { |
| 146 | log.Errorw("Failed to dial device", log.Fields{"ipPort": om.ipPort, "err": err}) |
| 147 | return err |
| 148 | } |
| 149 | om.openOltClient = oop.NewOpenoltClient(om.clientConn) |
| 150 | |
| 151 | // Populate Device Info |
| 152 | if deviceInfo, err := om.populateDeviceInfo(); err != nil { |
| 153 | log.Error("error fetching device info", log.Fields{"err": err, "deviceInfo": deviceInfo}) |
| 154 | return err |
| 155 | } |
| 156 | |
| 157 | // Read and load TPs to etcd. |
| 158 | om.readAndLoadTPsToEtcd() |
| 159 | |
| 160 | log.Info("etcd-up-and-running--tp-loaded-successfully") |
| 161 | |
| 162 | if om.rsrMgr = NewResourceMgr("ABCD", om.testConfig.KVStoreHost+":"+strconv.Itoa(om.testConfig.KVStorePort), |
| 163 | "etcd", "openolt", om.deviceInfo); om.rsrMgr == nil { |
| 164 | log.Error("Error while instantiating resource manager") |
| 165 | return errors.New("instantiating resource manager failed") |
| 166 | } |
| 167 | |
| 168 | om.TechProfile = make(map[uint32]*techprofile.TechProfileIf) |
| 169 | if err = om.populateTechProfilePerPonPort(); err != nil { |
| 170 | log.Error("Error while populating tech profile mgr\n") |
| 171 | return errors.New("error-loading-tech-profile-per-ponPort") |
| 172 | } |
| 173 | |
| 174 | // Start reading indications |
| 175 | go om.readIndications() |
| 176 | |
| 177 | // Provision OLT NNI Trap flows as needed by the Workflow |
| 178 | if err = ProvisionNniTrapFlow(om.openOltClient, om.testConfig, om.rsrMgr); err != nil { |
| 179 | log.Error("failed-to-add-nni-trap-flow", log.Fields{"err": err}) |
| 180 | } |
| 181 | |
| 182 | // Provision ONUs one by one |
| 183 | go om.provisionONUs() |
| 184 | |
| 185 | return nil |
| 186 | |
| 187 | } |
| 188 | |
| 189 | func (om *OpenOltManager) populateDeviceInfo() (*oop.DeviceInfo, error) { |
| 190 | var err error |
| 191 | |
| 192 | if om.deviceInfo, err = om.openOltClient.GetDeviceInfo(context.Background(), new(oop.Empty)); err != nil { |
| 193 | log.Errorw("Failed to fetch device info", log.Fields{"err": err}) |
| 194 | return nil, err |
| 195 | } |
| 196 | |
| 197 | if om.deviceInfo == nil { |
| 198 | log.Errorw("Device info is nil", log.Fields{}) |
| 199 | return nil, errors.New("failed to get device info from OLT") |
| 200 | } |
| 201 | |
| 202 | log.Debugw("Fetched device info", log.Fields{"deviceInfo": om.deviceInfo}) |
| 203 | |
| 204 | return om.deviceInfo, nil |
| 205 | } |
| 206 | |
| 207 | func (om *OpenOltManager) provisionONUs() { |
| 208 | var numOfONUsPerPon uint |
| 209 | var i, j, onuID uint32 |
| 210 | var err error |
| 211 | oltChan := make(chan bool) |
| 212 | numOfONUsPerPon = om.testConfig.NumOfOnu / uint(om.deviceInfo.PonPorts) |
| 213 | if oddONUs := om.testConfig.NumOfOnu % uint(om.deviceInfo.PonPorts); oddONUs > 0 { |
| 214 | log.Warnw("Odd number ONUs left out of provisioning", log.Fields{"oddONUs": oddONUs}) |
| 215 | } |
| 216 | totalOnusToProvision := numOfONUsPerPon * uint(om.deviceInfo.PonPorts) |
| 217 | log.Infow("***** all-onu-provision-started ******", |
| 218 | log.Fields{"totalNumOnus": totalOnusToProvision, |
| 219 | "numOfOnusPerPon": numOfONUsPerPon, |
| 220 | "numOfPons": om.deviceInfo.PonPorts}) |
| 221 | for i = 0; i < om.deviceInfo.PonPorts; i++ { |
| 222 | for j = 0; j < uint32(numOfONUsPerPon); j++ { |
| 223 | // TODO: More work with ONU provisioning |
| 224 | om.lockRsrAlloc.Lock() |
| 225 | sn := GenerateNextONUSerialNumber() |
| 226 | om.lockRsrAlloc.Unlock() |
| 227 | log.Debugw("provisioning onu", log.Fields{"onuID": j, "ponPort": i, "serialNum": sn}) |
| 228 | if onuID, err = om.rsrMgr.GetONUID(i); err != nil { |
| 229 | log.Errorw("error getting onu id", log.Fields{"err": err}) |
| 230 | continue |
| 231 | } |
| 232 | log.Infow("onu-provision-started-from-olt-manager", log.Fields{"onuId": onuID, "ponIntf": i}) |
| 233 | go om.activateONU(i, onuID, sn, om.stringifySerialNumber(sn), oltChan) |
| 234 | // Wait for complete ONU provision to succeed, including provisioning the subscriber |
| 235 | <-oltChan |
| 236 | log.Infow("onu-provision-completed-from-olt-manager", log.Fields{"onuId": onuID, "ponIntf": i}) |
| 237 | |
| 238 | // Sleep for configured time before provisioning next ONU |
| 239 | time.Sleep(time.Duration(om.testConfig.TimeIntervalBetweenSubs)) |
| 240 | } |
| 241 | } |
| 242 | log.Info("******** all-onu-provisioning-completed *******") |
| 243 | |
| 244 | // TODO: We need to dump the results at the end. But below json marshall does not work |
| 245 | // We will need custom Marshal function. |
| 246 | /* |
| 247 | e, err := json.Marshal(om) |
| 248 | if err != nil { |
| 249 | fmt.Println(err) |
| 250 | return |
| 251 | } |
| 252 | fmt.Println(string(e)) |
| 253 | */ |
| 254 | |
| 255 | // Stop the process once the job is done |
| 256 | _ = syscall.Kill(syscall.Getpid(), syscall.SIGINT) |
| 257 | } |
| 258 | |
| 259 | func (om *OpenOltManager) activateONU(intfID uint32, onuID uint32, serialNum *oop.SerialNumber, serialNumber string, oltCh chan bool) { |
| 260 | log.Debugw("activate-onu", log.Fields{"intfID": intfID, "onuID": onuID, "serialNum": serialNum, "serialNumber": serialNumber}) |
| 261 | // TODO: need resource manager |
| 262 | var pir uint32 = 1000000 |
| 263 | var onuDevice = OnuDevice{ |
| 264 | SerialNum: serialNumber, |
| 265 | OnuID: onuID, |
| 266 | PonIntf: intfID, |
| 267 | openOltClient: om.openOltClient, |
| 268 | testConfig: om.testConfig, |
| 269 | rsrMgr: om.rsrMgr, |
| 270 | } |
| 271 | var err error |
| 272 | onuDeviceKey := OnuDeviceKey{onuID: onuID, ponInfID: intfID} |
| 273 | Onu := oop.Onu{IntfId: intfID, OnuId: onuID, SerialNumber: serialNum, Pir: pir} |
| 274 | now := time.Now() |
| 275 | nanos := now.UnixNano() |
| 276 | milliStart := nanos / 1000000 |
| 277 | onuDevice.OnuProvisionStartTime = time.Unix(0, nanos) |
| 278 | if _, err = om.openOltClient.ActivateOnu(context.Background(), &Onu); err != nil { |
| 279 | st, _ := status.FromError(err) |
| 280 | if st.Code() == codes.AlreadyExists { |
| 281 | log.Debug("ONU activation is in progress", log.Fields{"SerialNumber": serialNumber}) |
| 282 | oltCh <- false |
| 283 | } else { |
| 284 | nanos = now.UnixNano() |
| 285 | milliEnd := nanos / 1000000 |
| 286 | onuDevice.OnuProvisionEndTime = time.Unix(0, nanos) |
| 287 | onuDevice.OnuProvisionDurationInMs = milliEnd - milliStart |
| 288 | log.Errorw("activate-onu-failed", log.Fields{"Onu": Onu, "err ": err}) |
| 289 | onuDevice.Reason = err.Error() |
| 290 | oltCh <- false |
| 291 | } |
| 292 | } else { |
| 293 | nanos = now.UnixNano() |
| 294 | milliEnd := nanos / 1000000 |
| 295 | onuDevice.OnuProvisionEndTime = time.Unix(0, nanos) |
| 296 | onuDevice.OnuProvisionDurationInMs = milliEnd - milliStart |
| 297 | onuDevice.Reason = ReasonOk |
| 298 | log.Infow("activated-onu", log.Fields{"SerialNumber": serialNumber}) |
| 299 | } |
| 300 | |
| 301 | om.OnuDeviceMap[onuDeviceKey] = &onuDevice |
| 302 | |
| 303 | // If ONU activation was success provision the ONU |
| 304 | if err == nil { |
| 305 | // start provisioning the ONU |
| 306 | go om.OnuDeviceMap[onuDeviceKey].Start(oltCh) |
| 307 | } |
| 308 | } |
| 309 | |
| 310 | func (om *OpenOltManager) stringifySerialNumber(serialNum *oop.SerialNumber) string { |
| 311 | if serialNum != nil { |
| 312 | return string(serialNum.VendorId) + om.stringifyVendorSpecific(serialNum.VendorSpecific) |
| 313 | } |
| 314 | return "" |
| 315 | } |
| 316 | |
| 317 | func (om *OpenOltManager) stringifyVendorSpecific(vendorSpecific []byte) string { |
| 318 | tmp := fmt.Sprintf("%x", (uint32(vendorSpecific[0])>>4)&0x0f) + |
| 319 | fmt.Sprintf("%x", uint32(vendorSpecific[0]&0x0f)) + |
| 320 | fmt.Sprintf("%x", (uint32(vendorSpecific[1])>>4)&0x0f) + |
| 321 | fmt.Sprintf("%x", (uint32(vendorSpecific[1]))&0x0f) + |
| 322 | fmt.Sprintf("%x", (uint32(vendorSpecific[2])>>4)&0x0f) + |
| 323 | fmt.Sprintf("%x", (uint32(vendorSpecific[2]))&0x0f) + |
| 324 | fmt.Sprintf("%x", (uint32(vendorSpecific[3])>>4)&0x0f) + |
| 325 | fmt.Sprintf("%x", (uint32(vendorSpecific[3]))&0x0f) |
| 326 | return tmp |
| 327 | } |
| 328 | |
| 329 | // readIndications to read the indications from the OLT device |
| 330 | func (om *OpenOltManager) readIndications() { |
| 331 | defer log.Errorw("Indications ended", log.Fields{}) |
| 332 | indications, err := om.openOltClient.EnableIndication(context.Background(), new(oop.Empty)) |
| 333 | if err != nil { |
| 334 | log.Errorw("Failed to read indications", log.Fields{"err": err}) |
| 335 | return |
| 336 | } |
| 337 | if indications == nil { |
| 338 | log.Errorw("Indications is nil", log.Fields{}) |
| 339 | return |
| 340 | } |
| 341 | |
| 342 | // Create an exponential backoff around re-enabling indications. The |
| 343 | // maximum elapsed time for the back off is set to 0 so that we will |
| 344 | // continue to retry. The max interval defaults to 1m, but is set |
| 345 | // here for code clarity |
| 346 | indicationBackoff := backoff.NewExponentialBackOff() |
| 347 | indicationBackoff.MaxElapsedTime = 0 |
| 348 | indicationBackoff.MaxInterval = 1 * time.Minute |
| 349 | for { |
| 350 | indication, err := indications.Recv() |
| 351 | if err == io.EOF { |
| 352 | log.Infow("EOF for indications", log.Fields{"err": err}) |
| 353 | // Use an exponential back off to prevent getting into a tight loop |
| 354 | duration := indicationBackoff.NextBackOff() |
| 355 | if duration == backoff.Stop { |
| 356 | // If we reach a maximum then warn and reset the backoff |
| 357 | // timer and keep attempting. |
| 358 | log.Warnw("Maximum indication backoff reached, resetting backoff timer", |
| 359 | log.Fields{"max_indication_backoff": indicationBackoff.MaxElapsedTime}) |
| 360 | indicationBackoff.Reset() |
| 361 | } |
| 362 | time.Sleep(indicationBackoff.NextBackOff()) |
| 363 | indications, err = om.openOltClient.EnableIndication(context.Background(), new(oop.Empty)) |
| 364 | if err != nil { |
| 365 | log.Errorw("Failed to read indications", log.Fields{"err": err}) |
| 366 | return |
| 367 | } |
| 368 | continue |
| 369 | } |
| 370 | if err != nil { |
| 371 | log.Infow("Failed to read from indications", log.Fields{"err": err}) |
| 372 | break |
| 373 | } |
| 374 | // Reset backoff if we have a successful receive |
| 375 | indicationBackoff.Reset() |
| 376 | om.handleIndication(indication) |
| 377 | |
| 378 | } |
| 379 | } |
| 380 | |
| 381 | func (om *OpenOltManager) handleIndication(indication *oop.Indication) { |
| 382 | switch indication.Data.(type) { |
| 383 | case *oop.Indication_OltInd: |
| 384 | log.Info("received olt indication") |
| 385 | case *oop.Indication_IntfInd: |
| 386 | intfInd := indication.GetIntfInd() |
| 387 | log.Infow("Received interface indication ", log.Fields{"InterfaceInd": intfInd}) |
| 388 | case *oop.Indication_IntfOperInd: |
| 389 | intfOperInd := indication.GetIntfOperInd() |
| 390 | if intfOperInd.GetType() == "nni" { |
| 391 | log.Info("received interface oper indication for nni port") |
| 392 | } else if intfOperInd.GetType() == "pon" { |
| 393 | log.Info("received interface oper indication for pon port") |
| 394 | } |
| 395 | /* |
| 396 | case *oop.Indication_OnuDiscInd: |
| 397 | onuDiscInd := indication.GetOnuDiscInd() |
| 398 | log.Infow("Received Onu discovery indication ", log.Fields{"OnuDiscInd": onuDiscInd}) |
| 399 | */ |
| 400 | case *oop.Indication_OnuInd: |
| 401 | onuInd := indication.GetOnuInd() |
| 402 | log.Infow("Received Onu indication ", log.Fields{"OnuInd": onuInd}) |
| 403 | case *oop.Indication_OmciInd: |
| 404 | omciInd := indication.GetOmciInd() |
| 405 | log.Debugw("Received Omci indication ", log.Fields{"IntfId": omciInd.IntfId, "OnuId": omciInd.OnuId, "pkt": hex.EncodeToString(omciInd.Pkt)}) |
| 406 | case *oop.Indication_PktInd: |
| 407 | pktInd := indication.GetPktInd() |
| 408 | log.Infow("Received pakcet indication ", log.Fields{"PktInd": pktInd}) |
| 409 | /* |
| 410 | case *oop.Indication_PortStats: |
| 411 | portStats := indication.GetPortStats() |
| 412 | log.Infow("Received port stats", log.Fields{"portStats": portStats}) |
| 413 | case *oop.Indication_FlowStats: |
| 414 | flowStats := indication.GetFlowStats() |
| 415 | log.Infow("Received flow stats", log.Fields{"FlowStats": flowStats}) |
| 416 | */ |
| 417 | case *oop.Indication_AlarmInd: |
| 418 | alarmInd := indication.GetAlarmInd() |
| 419 | log.Infow("Received alarm indication ", log.Fields{"AlarmInd": alarmInd}) |
| 420 | } |
| 421 | } |
| 422 | |
| 423 | func (om *OpenOltManager) populateTechProfilePerPonPort() error { |
| 424 | var tpCount int |
| 425 | for _, techRange := range om.deviceInfo.Ranges { |
| 426 | for _, intfID := range techRange.IntfIds { |
| 427 | om.TechProfile[intfID] = &(om.rsrMgr.ResourceMgrs[intfID].TechProfileMgr) |
| 428 | tpCount++ |
| 429 | log.Debugw("Init tech profile done", log.Fields{"intfID": intfID}) |
| 430 | } |
| 431 | } |
| 432 | //Make sure we have as many tech_profiles as there are pon ports on the device |
| 433 | if tpCount != int(om.deviceInfo.GetPonPorts()) { |
| 434 | log.Errorw("Error while populating techprofile", |
| 435 | log.Fields{"numofTech": tpCount, "numPonPorts": om.deviceInfo.GetPonPorts()}) |
| 436 | return errors.New("error while populating techprofile mgrs") |
| 437 | } |
| 438 | log.Infow("Populated techprofile for ponports successfully", |
| 439 | log.Fields{"numofTech": tpCount, "numPonPorts": om.deviceInfo.GetPonPorts()}) |
| 440 | return nil |
| 441 | } |