blob: 2b6c88972b4427d57fee4068330e2d38c42a4631 [file] [log] [blame]
option name = "tt-workflow-driver";
option app_label = "tt-workflow-driver";
message TtWorkflowDriverService (Service){
option verbose_name = "TtWorkflowDriver Service";
option kind = "control";
option description = "Service that manages the Turk Telekom Subscriber workflow";
}
message TtWorkflowDriverServiceInstance (ServiceInstance){
option owner_class_name = "TtWorkflowDriverService";
option verbose_name = "TtWorkflowDriver Service Instance";
option description = "Workflow settings for a particular ONU Device";
required string serial_number = 2 [
help_text = "Serial number of ONU",
max_length = 254,
tosca_key=True,
unique = True];
required string of_dpid = 4 [
help_text = "OLT Openflow ID",
max_length = 254];
required int32 uni_port_id = 5 [
help_text = "ONU UNI port ID"];
required string onu_state = 6 [
help_text = "ONU administrative state",
choices = "(('AWAITING', 'Awaiting'), ('ENABLED', 'Enabled'), ('DISABLED', 'Disabled'))",
default = "AWAITING",
feedback_state = True,
max_length = 254];
optional string status_message = 7 [
help_text = "Status text of current state machine state",
default = "",
max_length = 254];
required string dhcp_state = 8 [
max_length = 254,
default = "AWAITING",
choices = "(('AWAITING', 'Awaiting'), ('DHCPDISCOVER', 'DHCPDISCOVER'), ('DHCPACK', 'DHCPACK'), ('DHCPREQUEST', 'DHCPREQUEST'))",
feedback_state = True];
optional string ip_address = 9 [
help_text = "Management IP address, learned from DHCP",
feedback_state = True,
max_length = 20];
optional string mac_address = 10 [
help_text = "Management MAC address, leanred from DHCP",
feedback_state = True,
max_length = 20];
}
message TtWorkflowDriverWhiteListEntry (XOSBase) {
option verbose_name = "ONU Whitelist";
option plural = "ttworkflowdriverwhitelistentries";
option description = "White list entry that permits an ONU with a particular serial number on a particular OLT and PON";
required manytoone owner->TtWorkflowDriverService:whitelist_entries = 1:1001 [
help_text = "TtWorkflowDriverService that owns this white list entry",
db_index = True,
tosca_key = True];
required string serial_number = 2 [
help_text = "ONU Serial Number",
max_length = 254,
tosca_key = True,
unique_with = "owner"];
required int32 pon_port_id = 3 [
help_text = "PON Port on which this ONU is expected to show up"];
required string device_id = 4 [
help_text = "OLT Device (logical device id) on which this ONU is expected to show up",
max_length = 54];
}