blob: 7a28f81854766b0cd69c6915574af6604bb7eb8e [file] [log] [blame]
William Kurkian6f436d02019-02-06 16:25:01 -05001# Copyright 2017-present Adtran, Inc.
2#
3# Licensed under the Apache License, Version 2.0 (the "License");
4# you may not use this file except in compliance with the License.
5# You may obtain a copy of the License at
6#
7# http://www.apache.org/licenses/LICENSE-2.0
8#
9# Unless required by applicable law or agreed to in writing, software
10# distributed under the License is distributed on an "AS IS" BASIS,
11# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
12# See the License for the specific language governing permissions and
13# limitations under the License.
14from voltha.protos.events_pb2 import AlarmEventType, AlarmEventSeverity, AlarmEventCategory
15from voltha.extensions.alarms.adapter_alarms import AlarmBase
16
17
18class OnuTempYellowAlarm(AlarmBase):
19 """
20 The ONU Temperature Yellow Alarm is reported by both the CircuitPack
21 (ME #6) and the ONT-G (ME # 256) to indicate no service shutdown at
22 present, but the circuit pack is operating beyond its recommended range.
23
24 For CircuitPack equipment alarms, the intf_id reported is that of the
25 UNI's logical port number
26
27 For ONT-G equipment alarms, the intf_id reported is that of the PON/ANI
28 physical port number
29 """
30 def __init__(self, alarm_mgr, onu_id, intf_id):
31 super(OnuTempYellowAlarm, self).__init__(alarm_mgr, object_type='onu temperature yellow',
32 alarm='ONU_TEMP_YELLOW',
33 alarm_category=AlarmEventCategory.ONU,
34 alarm_type=AlarmEventType.ENVIRONMENT,
35 alarm_severity=AlarmEventSeverity.MAJOR)
36 self._onu_id = onu_id
37 self._intf_id = intf_id
38
39 def get_context_data(self):
40 return {'onu-id': self._onu_id,
41 'onu-intf-id': self._intf_id}