1. 01e8d97 VOL-3957: Re-org the meter reference count update code to account by Girish Gowdra · 3 years, 8 months ago voltha-2.7 v3.1.8
  2. 3fe4cc5 [VOL-3957]: Maintain meter reference counter and free up the meter from by Girish Gowdra · 3 years, 8 months ago v3.1.7
  3. 8458537 [VOL-3930] Using a shared lock for Resource acquisition and release by Matteo Scandolo · 3 years, 8 months ago v3.1.6
  4. c2c32a6 [VOL-3548] Differentiate between OLT gRPC channel disconnect and device reboot by Gamze Abaka · 3 years, 8 months ago
  5. a087056 VOL-3896: ONU fails to activate again if ONU is deleted after OLT disable by Girish Gowdra · 3 years, 8 months ago
  6. 7650be6 [VOL-3396] Enabling AES encryption by Gamze Abaka · 3 years, 9 months ago
  7. 8c9dc49 VOL-3791: Fix KPI_Event2 Metric timestamps (should be seconds since epoch) by Chip Boling · 3 years, 9 months ago
  8. b004675 VOL-3882 Changing onuIndications channel to per PON instead of per ONU by Mahir Gunyel · 3 years, 9 months ago
  9. 7b8211e [VOL-3801] remove consul support by serkant.uluderya · 3 years, 9 months ago
  10. 4dea631 [VOL-3865] Updating Alarm sub categories with correct ones by Andrea Campanella · 3 years, 9 months ago
  11. 1dc2bfb [VOL-3663] Modification to PPPoE Trap flows to support VLAN classifier info by Marcos Aurelio Carrero (Furukawa) · 3 years, 9 months ago
  12. 388fb0a [VOL-3663] Supporting PPPoE trap rules olt adapter by Marcos Aurelio Carrero (Furukawa) · 3 years, 9 months ago
  13. be811ff VOL-3777: Disable ONU and OLT failing sometimes at VOLTHA - stale devices exist even after delete by Girish Gowdra · 3 years, 10 months ago
  14. 6212621 VOL-3735 Retrieve port counters using the GetExtValue(SingleGetValue) rpc from the openolt adapter by kesavand · 3 years, 10 months ago v3.1.3
  15. fcbd6e7 VOL-3727 Support in OLT adapter to send periodic onu stats and gem stats by Gamze Abaka · 4 years ago v3.1.2
  16. 491a9c6 [VOL-3737] : Fix synchronization issues with mcast flow and group delete by Girish Gowdra · 3 years, 10 months ago v3.1.1
  17. cd40780 VOL-3501 Refeactoring of code for event handling by Himani Chawla · 4 years ago
  18. 0aca498 [VOL-3736]: Bug - Restarting multicast iperf server (at RG) will not restore the data stream at the RG. by Girish Gowdra · 3 years, 10 months ago
  19. 07868a5 VOL-3730 by Gamze Abaka · 4 years ago
  20. 2fb8147 VOL-3722 Processing onu related indications in occurence order by Mahir Gunyel · 4 years ago
  21. df392e1 VOL-3718 Packets coming from Open OLT Adapter to the VOLTHA Core always have zero in their UNI port field. OLT Adapter should set the true UNI port info to the control packets before passing them to the VOLTHA Core in the scope of packet-in workflow. by Esin Karaman · 4 years ago
  22. 49a5d56 VOL-3646 Fix for removal of DELETED admin state by Himani Chawla · 4 years ago
  23. 4aff186 [VOL-3644] fixed wrong topic names by serkant.uluderya · 4 years, 2 months ago
  24. dfa7a97 [VOL-3624] Parametrizing the KV-Store path by Matteo Scandolo · 4 years ago
  25. eb45029 Update log level of packet-in be at DebugLevel. by Girish Gowdra · 4 years, 1 month ago
  26. fb3d610 VOL-3521 : scale: intermittent issue - voltha complains that different meter is in use for subscriber by Girish Gowdra · 4 years, 1 month ago v3.0.1
  27. b1caa44 VOL-3557: OLT delete is causing the openolt adapter to panic sometimes by Girish Gowdra · 4 years, 1 month ago
  28. e8f473b - Add missing RWLock protection around accessing subscriberDataPathFlowIDMap. by Girish Gowdra · 4 years, 1 month ago
  29. a09aeab VOL-3419: OpenOLT adapter at scale constantly takes more that 10 seconds to react to flows by Girish Gowdra · 4 years, 2 months ago v3.0.0
  30. 2f6b5bc Adding onu and uni information to SedulerQueues errors by Matteo Scandolo · 4 years, 2 months ago
  31. 9602eb4 VOL-3419: OpenOLT adapter at scale constantly takes more that 10 seconds to react to flows by Girish Gowdra · 4 years, 2 months ago
  32. bfe0843 [VOL-3481] Returning error upon faliures in the divideAndAddFlow method by Andrea Campanella · 4 years, 2 months ago
  33. 7cf3a05 VOL-3444 Handling of ONT Activation Failure and generation of an alarm by kesavand · 4 years, 3 months ago
  34. 494c208 VOL-3395 Encryption of the OMCC GEM by kesavand · 4 years, 3 months ago v2.5.4
  35. 935f7af [VOL-3199] Added support for dynamic enable/disable of Trace Publishing by Girish Kumar · 4 years, 3 months ago v2.5.3
  36. 1183b4d Initialize the flowMgr.perGemPortLock MapMutex before invoking loadFlowIDlistForGem by Girish Gowdra · 4 years, 3 months ago
  37. 3af43e1 [VOL-3228] device-id logging consistancy by divyadesai · 4 years, 3 months ago
  38. a1ea2aa [VOL-3424] Switch completely to Context based Logger instance by Girish Kumar · 4 years, 3 months ago
  39. 738c52a Adding lock on flowsUsedByGemPort map Adding lock on OnuDevice.uniPorts map by Matteo Scandolo · 4 years, 3 months ago
  40. 8f4e432 [VOL-3141] Enhance Context with OpenTracing Span by Neha Sharma · 4 years, 3 months ago
  41. 0f6f8d0 Sending VLAN informations together with the DHCP flow by Matteo Scandolo · 4 years, 3 months ago v2.5.2
  42. 93e9174 [VOL-3196] Enhanced gRPC interfaces to create and propagate Span for log correlation by Girish Kumar · 4 years, 4 months ago
  43. cc0dce6 [VOL-3375]Remove field pkg from log statements by Rohan Agrawal · 4 years, 4 months ago
  44. e6ff101 VOL-3344 - Enabled default linters and fixed found issues. by Kent Hagerman · 4 years, 4 months ago
  45. 7fb80c2 VOL-3347 GEM ports kept for packet-outs should be in pon-onu-uni-vlan-pbit basis instead of per pon-onu-uni basis. by Esin Karaman · 4 years, 4 months ago
  46. d519bbf VOL-3112 Group removal support by Open OLT Adapter by Esin Karaman · 4 years, 5 months ago
  47. f1db18b VOL-3121 - Removing usage of device.Ports by Kent Hagerman · 4 years, 4 months ago
  48. 502056b VOL-3340: ONU events should contain both OLT and ONU device ID by Amit Ghosh · 4 years, 4 months ago
  49. abf9c51 [VOL-3269] Using a global lock on onuGemInfoLock by Matteo Scandolo · 4 years, 5 months ago
  50. 96b7bf2 [VOL-3069]Pass Context in methods which are performing logging and need the context by Neha Sharma · 4 years, 5 months ago
  51. 748de5c VOL-3314: ONU discovered entry is not cleared in OLT adapter on ONU by Girish Gowdra · 4 years, 5 months ago
  52. 2ba0e0b [VOL-1348] EPON tech profile support by Takahiro Suzuki · 4 years, 5 months ago
  53. 9218624 improving logs by Matteo Scandolo · 4 years, 5 months ago
  54. 631ef3d VOL-3202: Include port capability in the port create message. by Girish Gowdra · 4 years, 5 months ago
  55. da5e0b2 [VOL-3085]Implement UpdatePmConfig api for voltha-openolt-adapter by Rohan Agrawal · 4 years, 6 months ago
  56. 2c0d274 [VOL-3193] Moving OpenoltFlowManager lock on a per pon base by Matteo Scandolo · 4 years, 5 months ago
  57. 3f221ae [VOL-2736]:host and port should be specified as a single argument not as two separate arguments by Neha Sharma · 4 years, 7 months ago v2.4.8
  58. 95a3fcf VOL-3023 - enable stop indication while in backoff by David Bainbridge · 4 years, 5 months ago
  59. 89ae6d8 VOL-3155: Synchronize flow-removal and ONU delete handling by Girish Gowdra · 4 years, 6 months ago
  60. a1efa64 VOL-2324 Alarm - ONU Itu Pon Stats by Devmalya Paul · 4 years, 7 months ago v2.4.7
  61. c0878ec [VOL-2952] :changes to fill port labels for PON ports with easily understandable values by Chaitrashree G S · 4 years, 6 months ago
  62. 75f0e29 VOL-3095: Added olt device_id in ONU Discovery Event by Amit Ghosh · 4 years, 6 months ago
  63. 8c9b4f6 Lowering frequent and long log by Andrea Campanella · 4 years, 6 months ago
  64. 2691297 [VOL-2930] Changed log behaviour for openolt adapter by Shrey Baid · 4 years, 7 months ago v2.4.6
  65. 34815db VOL-3065: Concurrent metrics context map access causing panic by Girish Gowdra · 4 years, 6 months ago
  66. 429f950 VOL-2973: ONT Reboot is not bringing ONU back to 'omci-flows-pushed' state by Girish Gowdra · 4 years, 6 months ago
  67. c43a66e [VOL-3068] Openolt flow manager must support set_field action for vlan_pcp by Gamze Abaka · 4 years, 6 months ago
  68. 985938d VOL-2967: Remove redundant variables from DeviceHandler struct by Thomas Lee S · 4 years, 7 months ago
  69. aaf9c10 VOL-2948: Added PON and NNI information to metrics by Kishore Darapu · 4 years, 7 months ago v2.4.5
  70. 807a2a0 [VOL-2889] adding devicehandler logs addtl. features by Shrey Baid · 4 years, 7 months ago v2.4.4
  71. eb5294e VOL-897 Onu Differential Reach Exceeded Alarm by Devmalya Paul · 4 years, 8 months ago v2.4.3
  72. 78a1d2a [VOL-2975] Changes to OpenOLT adapter for supporting multi-tcont by Gamze Abaka · 4 years, 7 months ago
  73. 3262521 [VOL-2990] - Fix missing type assertion for IgmpProto classifier by Girish Gowdra · 4 years, 7 months ago
  74. 9931ad6 [VOL-936] Missing mocks and comments. Lowering log level for chatty messages by Andrea Campanella · 4 years, 7 months ago
  75. db587af [VOL-936] Add changes for onu distance from olt by Dinesh Belwalkar · 4 years, 9 months ago
  76. 724d085 [VOL-2774] Allow not filtering the pbit values for the TT workflow by Gamze Abaka · 4 years, 8 months ago
  77. d625b4c [VOL-2890] Using olt-device-id in the path of a tech-profile by Matteo Scandolo · 4 years, 8 months ago v2.4.2
  78. 0f89fd2 VOL-2916 Use cached values instead of childDevice query by Mahir Gunyel · 4 years, 7 months ago
  79. 85f3731 VOL-2880: Reduction of Unit Test Time by Thomas Lee S · 4 years, 8 months ago
  80. b77ded9 [VOL-2895] : Pings fail intermittently after OLT reboot and ONU disable by Girish Gowdra · 4 years, 7 months ago v2.4.0
  81. c4b1911 Avoid crash when trying to log nil group.Desc by Jonathan Hart · 4 years, 8 months ago
  82. 38d533d [VOL-2848] : Protect concurrent access for PON resources by Girish Gowdra · 4 years, 8 months ago
  83. 24f83e2 VOL-2776 Start_omci_test is unimplemented for OLT by Scott Baker · 4 years, 8 months ago
  84. 668ea5f [VOL-2643] Removing unused UpdateOnuGemInfo by Andrea Campanella · 4 years, 8 months ago
  85. ceea2e0 VOL-2841: Remove old backward compatible omci message checking code by Matt Jeanneret · 4 years, 8 months ago
  86. 868131c [VOL-2845]: Fix concurrent access of SouthBoundPort data in statsmanager module by Girish Gowdra · 4 years, 8 months ago
  87. b83b39d [VOL-2638] Returning error when storing data for new ONU by Andrea Campanella · 4 years, 8 months ago
  88. 3ab6d21 [VOL-2801] : Following OLT reboot, the readIndication receive stream would have by Girish Gowdra · 4 years, 8 months ago
  89. 3f97491 [VOL-2801] : readIndication routine going in an infinite loop on delete device. by Girish Gowdra · 4 years, 8 months ago
  90. 2ad402b [VOL-2694] Use package specific logger instance in all log statements by Girish Kumar · 4 years, 8 months ago
  91. d26f6b1 [VOL-2782] Update go.mod of voltha-go,open-olt-adapter,ofagent-go and voltctl to be compatible with latest version of voltha-lig-go by divyadesai · 4 years, 8 months ago
  92. 65409d8 VOL-2775 Multicast flows can not be installed due to the following error. by Esin Karaman · 4 years, 8 months ago
  93. cefae19 [VOL-2786] : Handle flow deletes completely before proceeding onto by Girish Gowdra · 4 years, 8 months ago
  94. a464925 [VOL-2741]: code changes to support OLT reboot by Chaitrashree G S · 4 years, 8 months ago
  95. 2440047 VOL-2747 Alarms should log at DEBUG level by Devmalya Paul · 4 years, 8 months ago v2.3.19
  96. 34a0028 VOL-812: If fiber is pulled at ONU side, ONU LOS alarm will not get clear from kafka bus. by Thiyagarajan Subramani · 4 years, 8 months ago v2.3.18
  97. f26e488 [VOL-2612] Remove error log when returning error from methods by Girish Kumar · 4 years, 9 months ago v2.3.17
  98. 41a762d VOL-883 Onu Loss of Acknowledgement Alarm by Devmalya Paul · 4 years, 9 months ago v2.3.16
  99. c63bba9 [VOL-2641] Returning errors for flows and groups from the open olt adapter to the core by Andrea Campanella · 4 years, 8 months ago v2.3.15
  100. bcdb144 VOL-2691 ONU Discovery event not raised by Devmalya Paul · 4 years, 9 months ago