| /* |
| * Copyright 2020-present Open Networking Foundation |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| //Package adaptercoreonu provides the utility for onu devices, flows and statistics |
| package adaptercoreonu |
| |
| import ( |
| "context" |
| "encoding/hex" |
| "errors" |
| "fmt" |
| "strconv" |
| "sync" |
| "time" |
| |
| "github.com/gogo/protobuf/proto" |
| "github.com/golang/protobuf/ptypes" |
| "github.com/looplab/fsm" |
| me "github.com/opencord/omci-lib-go/generated" |
| "github.com/opencord/voltha-lib-go/v4/pkg/adapters/adapterif" |
| "github.com/opencord/voltha-lib-go/v4/pkg/db" |
| flow "github.com/opencord/voltha-lib-go/v4/pkg/flows" |
| "github.com/opencord/voltha-lib-go/v4/pkg/log" |
| vc "github.com/opencord/voltha-protos/v4/go/common" |
| ic "github.com/opencord/voltha-protos/v4/go/inter_container" |
| "github.com/opencord/voltha-protos/v4/go/openflow_13" |
| of "github.com/opencord/voltha-protos/v4/go/openflow_13" |
| ofp "github.com/opencord/voltha-protos/v4/go/openflow_13" |
| oop "github.com/opencord/voltha-protos/v4/go/openolt" |
| "github.com/opencord/voltha-protos/v4/go/voltha" |
| ) |
| |
| /* |
| // Constants for number of retries and for timeout |
| const ( |
| MaxRetry = 10 |
| MaxTimeOutInMs = 500 |
| ) |
| */ |
| |
| const ( |
| // events of Device FSM |
| devEvDeviceInit = "devEvDeviceInit" |
| devEvGrpcConnected = "devEvGrpcConnected" |
| devEvGrpcDisconnected = "devEvGrpcDisconnected" |
| devEvDeviceUpInd = "devEvDeviceUpInd" |
| devEvDeviceDownInd = "devEvDeviceDownInd" |
| ) |
| const ( |
| // states of Device FSM |
| devStNull = "devStNull" |
| devStDown = "devStDown" |
| devStInit = "devStInit" |
| devStConnected = "devStConnected" |
| devStUp = "devStUp" |
| ) |
| |
| //Event category and subcategory definitions - same as defiend for OLT in eventmgr.go - should be done more centrally |
| const ( |
| pon = voltha.EventSubCategory_PON |
| //olt = voltha.EventSubCategory_OLT |
| //ont = voltha.EventSubCategory_ONT |
| //onu = voltha.EventSubCategory_ONU |
| //nni = voltha.EventSubCategory_NNI |
| //service = voltha.EventCategory_SERVICE |
| //security = voltha.EventCategory_SECURITY |
| equipment = voltha.EventCategory_EQUIPMENT |
| //processing = voltha.EventCategory_PROCESSING |
| //environment = voltha.EventCategory_ENVIRONMENT |
| //communication = voltha.EventCategory_COMMUNICATION |
| ) |
| |
| const ( |
| cEventObjectType = "ONU" |
| ) |
| const ( |
| cOnuActivatedEvent = "ONU_ACTIVATED" |
| ) |
| |
| const ( |
| // device reasons |
| drUnset = 0 |
| drActivatingOnu = 1 |
| drStartingOpenomci = 2 |
| drDiscoveryMibsyncComplete = 3 |
| drInitialMibDownloaded = 4 |
| drTechProfileConfigDownloadSuccess = 5 |
| drOmciFlowsPushed = 6 |
| drOmciAdminLock = 7 |
| drOnuReenabled = 8 |
| drStoppingOpenomci = 9 |
| drRebooting = 10 |
| drOmciFlowsDeleted = 11 |
| drTechProfileConfigDeleteSuccess = 12 |
| ) |
| |
| var deviceReasonMap = map[uint8]string{ |
| drUnset: "unset", |
| drActivatingOnu: "activating-onu", |
| drStartingOpenomci: "starting-openomci", |
| drDiscoveryMibsyncComplete: "discovery-mibsync-complete", |
| drInitialMibDownloaded: "initial-mib-downloaded", |
| drTechProfileConfigDownloadSuccess: "tech-profile-config-download-success", |
| drOmciFlowsPushed: "omci-flows-pushed", |
| drOmciAdminLock: "omci-admin-lock", |
| drOnuReenabled: "onu-reenabled", |
| drStoppingOpenomci: "stopping-openomci", |
| drRebooting: "rebooting", |
| drOmciFlowsDeleted: "omci-flows-deleted", |
| drTechProfileConfigDeleteSuccess: "tech-profile-config-delete-success", |
| } |
| |
| //deviceHandler will interact with the ONU ? device. |
| type deviceHandler struct { |
| deviceID string |
| DeviceType string |
| adminState string |
| device *voltha.Device |
| logicalDeviceID string |
| ProxyAddressID string |
| ProxyAddressType string |
| parentID string |
| ponPortNumber uint32 |
| |
| coreProxy adapterif.CoreProxy |
| AdapterProxy adapterif.AdapterProxy |
| EventProxy adapterif.EventProxy |
| |
| pOpenOnuAc *OpenONUAC |
| pDeviceStateFsm *fsm.FSM |
| //pPonPort *voltha.Port |
| deviceEntrySet chan bool //channel for DeviceEntry set event |
| pOnuOmciDevice *OnuDeviceEntry |
| pOnuTP *onuUniTechProf |
| exitChannel chan int |
| lockDevice sync.RWMutex |
| pOnuIndication *oop.OnuIndication |
| deviceReason uint8 |
| pLockStateFsm *lockStateFsm |
| pUnlockStateFsm *lockStateFsm |
| |
| //flowMgr *OpenOltFlowMgr |
| //eventMgr *OpenOltEventMgr |
| //resourceMgr *rsrcMgr.OpenOltResourceMgr |
| |
| //discOnus sync.Map |
| //onus sync.Map |
| //portStats *OpenOltStatisticsMgr |
| //metrics *pmmetrics.PmMetrics |
| stopCollector chan bool |
| stopHeartbeatCheck chan bool |
| activePorts sync.Map |
| uniEntityMap map[uint32]*onuUniPort |
| UniVlanConfigFsmMap map[uint8]*UniVlanConfigFsm |
| reconciling bool |
| ReadyForSpecificOmciConfig bool |
| } |
| |
| //newDeviceHandler creates a new device handler |
| func newDeviceHandler(ctx context.Context, cp adapterif.CoreProxy, ap adapterif.AdapterProxy, ep adapterif.EventProxy, device *voltha.Device, adapter *OpenONUAC) *deviceHandler { |
| var dh deviceHandler |
| dh.coreProxy = cp |
| dh.AdapterProxy = ap |
| dh.EventProxy = ep |
| cloned := (proto.Clone(device)).(*voltha.Device) |
| dh.deviceID = cloned.Id |
| dh.DeviceType = cloned.Type |
| dh.adminState = "up" |
| dh.device = cloned |
| dh.pOpenOnuAc = adapter |
| dh.exitChannel = make(chan int, 1) |
| dh.lockDevice = sync.RWMutex{} |
| dh.deviceEntrySet = make(chan bool, 1) |
| dh.stopCollector = make(chan bool, 2) |
| dh.stopHeartbeatCheck = make(chan bool, 2) |
| //dh.metrics = pmmetrics.NewPmMetrics(cloned.Id, pmmetrics.Frequency(150), pmmetrics.FrequencyOverride(false), pmmetrics.Grouped(false), pmmetrics.Metrics(pmNames)) |
| dh.activePorts = sync.Map{} |
| //TODO initialize the support classes. |
| dh.uniEntityMap = make(map[uint32]*onuUniPort) |
| dh.UniVlanConfigFsmMap = make(map[uint8]*UniVlanConfigFsm) |
| dh.reconciling = false |
| dh.ReadyForSpecificOmciConfig = false |
| |
| // Device related state machine |
| dh.pDeviceStateFsm = fsm.NewFSM( |
| devStNull, |
| fsm.Events{ |
| {Name: devEvDeviceInit, Src: []string{devStNull, devStDown}, Dst: devStInit}, |
| {Name: devEvGrpcConnected, Src: []string{devStInit}, Dst: devStConnected}, |
| {Name: devEvGrpcDisconnected, Src: []string{devStConnected, devStDown}, Dst: devStInit}, |
| {Name: devEvDeviceUpInd, Src: []string{devStConnected, devStDown}, Dst: devStUp}, |
| {Name: devEvDeviceDownInd, Src: []string{devStUp}, Dst: devStDown}, |
| }, |
| fsm.Callbacks{ |
| "before_event": func(e *fsm.Event) { dh.logStateChange(ctx, e) }, |
| ("before_" + devEvDeviceInit): func(e *fsm.Event) { dh.doStateInit(ctx, e) }, |
| ("after_" + devEvDeviceInit): func(e *fsm.Event) { dh.postInit(ctx, e) }, |
| ("before_" + devEvGrpcConnected): func(e *fsm.Event) { dh.doStateConnected(ctx, e) }, |
| ("before_" + devEvGrpcDisconnected): func(e *fsm.Event) { dh.doStateInit(ctx, e) }, |
| ("after_" + devEvGrpcDisconnected): func(e *fsm.Event) { dh.postInit(ctx, e) }, |
| ("before_" + devEvDeviceUpInd): func(e *fsm.Event) { dh.doStateUp(ctx, e) }, |
| ("before_" + devEvDeviceDownInd): func(e *fsm.Event) { dh.doStateDown(ctx, e) }, |
| }, |
| ) |
| |
| return &dh |
| } |
| |
| // start save the device to the data model |
| func (dh *deviceHandler) start(ctx context.Context) { |
| logger.Debugw(ctx, "starting-device-handler", log.Fields{"device": dh.device, "device-id": dh.deviceID}) |
| // Add the initial device to the local model |
| logger.Debug(ctx, "device-handler-started") |
| } |
| |
| /* |
| // stop stops the device dh. Not much to do for now |
| func (dh *deviceHandler) stop(ctx context.Context) { |
| logger.Debug("stopping-device-handler") |
| dh.exitChannel <- 1 |
| } |
| */ |
| |
| // ########################################################################################## |
| // deviceHandler methods that implement the adapters interface requests ##### begin ######### |
| |
| //adoptOrReconcileDevice adopts the OLT device |
| func (dh *deviceHandler) adoptOrReconcileDevice(ctx context.Context, device *voltha.Device) { |
| logger.Debugw(ctx, "Adopt_or_reconcile_device", log.Fields{"device-id": device.Id, "Address": device.GetHostAndPort()}) |
| |
| logger.Debugw(ctx, "Device FSM: ", log.Fields{"state": string(dh.pDeviceStateFsm.Current())}) |
| if dh.pDeviceStateFsm.Is(devStNull) { |
| if err := dh.pDeviceStateFsm.Event(devEvDeviceInit); err != nil { |
| logger.Errorw(ctx, "Device FSM: Can't go to state DeviceInit", log.Fields{"err": err}) |
| } |
| logger.Debugw(ctx, "Device FSM: ", log.Fields{"state": string(dh.pDeviceStateFsm.Current())}) |
| } else { |
| logger.Debugw(ctx, "AdoptOrReconcileDevice: Agent/device init already done", log.Fields{"device-id": device.Id}) |
| } |
| |
| } |
| |
| func (dh *deviceHandler) processInterAdapterOMCIReqMessage(ctx context.Context, msg *ic.InterAdapterMessage) error { |
| msgBody := msg.GetBody() |
| omciMsg := &ic.InterAdapterOmciMessage{} |
| if err := ptypes.UnmarshalAny(msgBody, omciMsg); err != nil { |
| logger.Warnw(ctx, "cannot-unmarshal-omci-msg-body", log.Fields{ |
| "device-id": dh.deviceID, "error": err}) |
| return err |
| } |
| |
| //assuming omci message content is hex coded! |
| // with restricted output of 16(?) bytes would be ...omciMsg.Message[:16] |
| logger.Debugw(ctx, "inter-adapter-recv-omci", log.Fields{ |
| "device-id": dh.deviceID, "RxOmciMessage": hex.EncodeToString(omciMsg.Message)}) |
| //receive_message(omci_msg.message) |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry != nil { |
| if pDevEntry.PDevOmciCC != nil { |
| return pDevEntry.PDevOmciCC.receiveMessage(log.WithSpanFromContext(context.TODO(), ctx), omciMsg.Message) |
| } |
| logger.Debugw(ctx, "omciCC not ready to receive omci messages - incoming omci message ignored", log.Fields{"rxMsg": omciMsg.Message}) |
| } |
| logger.Errorw(ctx, "No valid OnuDevice -aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| |
| func (dh *deviceHandler) processInterAdapterTechProfileDownloadReqMessage( |
| ctx context.Context, |
| msg *ic.InterAdapterMessage) error { |
| |
| logger.Infow(ctx, "tech-profile-download-request", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| if dh.pOnuTP == nil { |
| //should normally not happen ... |
| logger.Errorw(ctx, "onuTechProf instance not set up for DLMsg request - ignoring request", |
| log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("techProfile DLMsg request while onuTechProf instance not setup: %s", dh.deviceID) |
| } |
| if !dh.ReadyForSpecificOmciConfig { |
| logger.Errorw(ctx, "TechProf-set rejected: improper device state", log.Fields{"device-id": dh.deviceID, |
| "device-state": deviceReasonMap[dh.deviceReason]}) |
| return fmt.Errorf("improper device state %s on device %s", deviceReasonMap[dh.deviceReason], dh.deviceID) |
| } |
| //previous state test here was just this one, now extended for more states to reject the SetRequest: |
| // at least 'mib-downloaded' should be reached for processing of this specific ONU configuration |
| // if (dh.deviceReason == "stopping-openomci") || (dh.deviceReason == "omci-admin-lock") |
| |
| msgBody := msg.GetBody() |
| techProfMsg := &ic.InterAdapterTechProfileDownloadMessage{} |
| if err := ptypes.UnmarshalAny(msgBody, techProfMsg); err != nil { |
| logger.Warnw(ctx, "cannot-unmarshal-techprof-msg-body", log.Fields{ |
| "device-id": dh.deviceID, "error": err}) |
| return err |
| } |
| |
| // we have to lock access to TechProfile processing based on different messageType calls or |
| // even to fast subsequent calls of the same messageType as well as OnuKVStore processing due |
| // to possible concurrent access by flow processing |
| dh.pOnuTP.lockTpProcMutex() |
| defer dh.pOnuTP.unlockTpProcMutex() |
| pDevEntry.lockOnuKVStoreMutex() |
| defer pDevEntry.unlockOnuKVStoreMutex() |
| |
| if techProfMsg.UniId > 255 { |
| return fmt.Errorf(fmt.Sprintf("received UniId value exceeds range: %d, device-id: %s", |
| techProfMsg.UniId, dh.deviceID)) |
| } |
| uniID := uint8(techProfMsg.UniId) |
| tpID, err := GetTpIDFromTpPath(techProfMsg.Path) |
| if err != nil { |
| logger.Errorw(ctx, "error-parsing-tpid-from-tppath", log.Fields{"err": err, "tp-path": techProfMsg.Path}) |
| return err |
| } |
| |
| if bTpModify := pDevEntry.updateOnuUniTpPath(ctx, uniID, uint8(tpID), techProfMsg.Path); bTpModify { |
| // if there has been some change for some uni TechProfilePath |
| //in order to allow concurrent calls to other dh instances we do not wait for execution here |
| //but doing so we can not indicate problems to the caller (who does what with that then?) |
| //by now we just assume straightforward successful execution |
| //TODO!!! Generally: In this scheme it would be good to have some means to indicate |
| // possible problems to the caller later autonomously |
| |
| // deadline context to ensure completion of background routines waited for |
| //20200721: 10s proved to be less in 8*8 ONU test on local vbox machine with debug, might be further adapted |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(context.Background(), deadline) |
| |
| dh.pOnuTP.resetTpProcessingErrorIndication(uniID, tpID) |
| pDevEntry.resetKvProcessingErrorIndication() |
| |
| var wg sync.WaitGroup |
| wg.Add(2) // for the 2 go routines to finish |
| // attention: deadline completion check and wg.Done is to be done in both routines |
| go dh.pOnuTP.configureUniTp(log.WithSpanFromContext(dctx, ctx), uniID, techProfMsg.Path, &wg) |
| go pDevEntry.updateOnuKvStore(log.WithSpanFromContext(dctx, ctx), &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "TechProfDwld") //wait for background process to finish |
| |
| return dh.combineErrorStrings(dh.pOnuTP.getTpProcessingErrorIndication(uniID, tpID), pDevEntry.getKvProcessingErrorIndication()) |
| } |
| // no change, nothing really to do - return success |
| return nil |
| } |
| |
| func (dh *deviceHandler) processInterAdapterDeleteGemPortReqMessage( |
| ctx context.Context, |
| msg *ic.InterAdapterMessage) error { |
| |
| logger.Infow(ctx, "delete-gem-port-request", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| if dh.pOnuTP == nil { |
| //should normally not happen ... |
| logger.Warnw(ctx, "onuTechProf instance not set up for DelGem request - ignoring request", |
| log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("techProfile DelGem request while onuTechProf instance not setup: %s", dh.deviceID) |
| } |
| |
| msgBody := msg.GetBody() |
| delGemPortMsg := &ic.InterAdapterDeleteGemPortMessage{} |
| if err := ptypes.UnmarshalAny(msgBody, delGemPortMsg); err != nil { |
| logger.Warnw(ctx, "cannot-unmarshal-delete-gem-msg-body", log.Fields{ |
| "device-id": dh.deviceID, "error": err}) |
| return err |
| } |
| |
| //compare TECH_PROFILE_DOWNLOAD_REQUEST |
| dh.pOnuTP.lockTpProcMutex() |
| defer dh.pOnuTP.unlockTpProcMutex() |
| pDevEntry.lockOnuKVStoreMutex() |
| defer pDevEntry.unlockOnuKVStoreMutex() |
| |
| if delGemPortMsg.UniId > 255 { |
| return fmt.Errorf(fmt.Sprintf("received UniId value exceeds range: %d, device-id: %s", |
| delGemPortMsg.UniId, dh.deviceID)) |
| } |
| uniID := uint8(delGemPortMsg.UniId) |
| tpID, err := GetTpIDFromTpPath(delGemPortMsg.TpPath) |
| if err != nil { |
| logger.Errorw(ctx, "error-extracting-tp-id-from-tp-path", log.Fields{"err": err, "tp-path": delGemPortMsg.TpPath}) |
| return err |
| } |
| |
| //a removal of some GemPort would never remove the complete TechProfile entry (done on T-Cont) |
| |
| // deadline context to ensure completion of background routines waited for |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(context.Background(), deadline) |
| |
| dh.pOnuTP.resetTpProcessingErrorIndication(uniID, tpID) |
| |
| var wg sync.WaitGroup |
| wg.Add(1) // for the 1 go routine to finish |
| go dh.pOnuTP.deleteTpResource(log.WithSpanFromContext(dctx, ctx), uniID, tpID, delGemPortMsg.TpPath, |
| cResourceGemPort, delGemPortMsg.GemPortId, &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "GemDelete") //wait for background process to finish |
| |
| return dh.pOnuTP.getTpProcessingErrorIndication(uniID, tpID) |
| } |
| |
| func (dh *deviceHandler) processInterAdapterDeleteTcontReqMessage( |
| ctx context.Context, |
| msg *ic.InterAdapterMessage) error { |
| |
| logger.Infow(ctx, "delete-tcont-request", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| if dh.pOnuTP == nil { |
| //should normally not happen ... |
| logger.Warnw(ctx, "onuTechProf instance not set up for DelTcont request - ignoring request", |
| log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("techProfile DelTcont request while onuTechProf instance not setup: %s", dh.deviceID) |
| } |
| |
| msgBody := msg.GetBody() |
| delTcontMsg := &ic.InterAdapterDeleteTcontMessage{} |
| if err := ptypes.UnmarshalAny(msgBody, delTcontMsg); err != nil { |
| logger.Warnw(ctx, "cannot-unmarshal-delete-tcont-msg-body", log.Fields{ |
| "device-id": dh.deviceID, "error": err}) |
| return err |
| } |
| |
| //compare TECH_PROFILE_DOWNLOAD_REQUEST |
| dh.pOnuTP.lockTpProcMutex() |
| defer dh.pOnuTP.unlockTpProcMutex() |
| pDevEntry.lockOnuKVStoreMutex() |
| defer pDevEntry.unlockOnuKVStoreMutex() |
| |
| if delTcontMsg.UniId > 255 { |
| return fmt.Errorf(fmt.Sprintf("received UniId value exceeds range: %d, device-id: %s", |
| delTcontMsg.UniId, dh.deviceID)) |
| } |
| uniID := uint8(delTcontMsg.UniId) |
| tpPath := delTcontMsg.TpPath |
| tpID, err := GetTpIDFromTpPath(tpPath) |
| if err != nil { |
| logger.Errorw(ctx, "error-extracting-tp-id-from-tp-path", log.Fields{"err": err, "tp-path": tpPath}) |
| return err |
| } |
| |
| if bTpModify := pDevEntry.updateOnuUniTpPath(ctx, uniID, tpID, ""); bTpModify { |
| // deadline context to ensure completion of background routines waited for |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(context.Background(), deadline) |
| |
| dh.pOnuTP.resetTpProcessingErrorIndication(uniID, tpID) |
| pDevEntry.resetKvProcessingErrorIndication() |
| |
| var wg sync.WaitGroup |
| wg.Add(2) // for the 2 go routines to finish |
| go dh.pOnuTP.deleteTpResource(log.WithSpanFromContext(dctx, ctx), uniID, tpID, delTcontMsg.TpPath, |
| cResourceTcont, delTcontMsg.AllocId, &wg) |
| // Removal of the tcont/alloc id mapping represents the removal of the tech profile |
| go pDevEntry.updateOnuKvStore(log.WithSpanFromContext(dctx, ctx), &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "TContDelete") //wait for background process to finish |
| |
| return dh.combineErrorStrings(dh.pOnuTP.getTpProcessingErrorIndication(uniID, tpID), pDevEntry.getKvProcessingErrorIndication()) |
| } |
| return nil |
| } |
| |
| //processInterAdapterMessage sends the proxied messages to the target device |
| // If the proxy address is not found in the unmarshalled message, it first fetches the onu device for which the message |
| // is meant, and then send the unmarshalled omci message to this onu |
| func (dh *deviceHandler) processInterAdapterMessage(ctx context.Context, msg *ic.InterAdapterMessage) error { |
| msgID := msg.Header.Id |
| msgType := msg.Header.Type |
| fromTopic := msg.Header.FromTopic |
| toTopic := msg.Header.ToTopic |
| toDeviceID := msg.Header.ToDeviceId |
| proxyDeviceID := msg.Header.ProxyDeviceId |
| logger.Debugw(ctx, "InterAdapter message header", log.Fields{"msgID": msgID, "msgType": msgType, |
| "fromTopic": fromTopic, "toTopic": toTopic, "toDeviceID": toDeviceID, "proxyDeviceID": proxyDeviceID}) |
| |
| switch msgType { |
| // case ic.InterAdapterMessageType_ONU_IND_REQUEST: was handled by OpenONUAC already - see comments there |
| case ic.InterAdapterMessageType_OMCI_REQUEST: |
| { |
| return dh.processInterAdapterOMCIReqMessage(ctx, msg) |
| } |
| case ic.InterAdapterMessageType_TECH_PROFILE_DOWNLOAD_REQUEST: |
| { |
| return dh.processInterAdapterTechProfileDownloadReqMessage(ctx, msg) |
| } |
| case ic.InterAdapterMessageType_DELETE_GEM_PORT_REQUEST: |
| { |
| return dh.processInterAdapterDeleteGemPortReqMessage(ctx, msg) |
| |
| } |
| case ic.InterAdapterMessageType_DELETE_TCONT_REQUEST: |
| { |
| return dh.processInterAdapterDeleteTcontReqMessage(ctx, msg) |
| } |
| default: |
| { |
| logger.Errorw(ctx, "inter-adapter-unhandled-type", log.Fields{ |
| "msgType": msg.Header.Type, "device-id": dh.deviceID}) |
| return fmt.Errorf("inter-adapter-unhandled-type: %d, %s", msg.Header.Type, dh.deviceID) |
| } |
| } |
| } |
| |
| //FlowUpdateIncremental removes and/or adds the flow changes on a given device |
| func (dh *deviceHandler) FlowUpdateIncremental(ctx context.Context, |
| apOfFlowChanges *openflow_13.FlowChanges, |
| apOfGroupChanges *openflow_13.FlowGroupChanges, apFlowMetaData *voltha.FlowMetadata) error { |
| logger.Debugw(ctx, "FlowUpdateIncremental started", log.Fields{"device-id": dh.deviceID}) |
| |
| var retError error = nil |
| //Remove flows (always remove flows first - remove old and add new with same cookie may be part of the same request) |
| if apOfFlowChanges.ToRemove != nil { |
| for _, flowItem := range apOfFlowChanges.ToRemove.Items { |
| if flowItem.GetCookie() == 0 { |
| logger.Warnw(ctx, "flow-remove no cookie: ignore and continuing on checking further flows", log.Fields{ |
| "device-id": dh.deviceID}) |
| retError = fmt.Errorf("flow-remove no cookie, device-id %s", dh.deviceID) |
| continue |
| } |
| flowInPort := flow.GetInPort(flowItem) |
| if flowInPort == uint32(of.OfpPortNo_OFPP_INVALID) { |
| logger.Warnw(ctx, "flow-remove inPort invalid: ignore and continuing on checking further flows", log.Fields{"device-id": dh.deviceID}) |
| retError = fmt.Errorf("flow-remove inPort invalid, device-id %s", dh.deviceID) |
| continue |
| //return fmt.Errorf("flow inPort invalid: %s", dh.deviceID) |
| } else if flowInPort == dh.ponPortNumber { |
| //this is some downstream flow, not regarded as error, just ignored |
| logger.Debugw(ctx, "flow-remove for downstream: ignore and continuing on checking further flows", log.Fields{ |
| "device-id": dh.deviceID, "inPort": flowInPort}) |
| continue |
| } else { |
| // this is the relevant upstream flow |
| var loUniPort *onuUniPort |
| if uniPort, exist := dh.uniEntityMap[flowInPort]; exist { |
| loUniPort = uniPort |
| } else { |
| logger.Warnw(ctx, "flow-remove inPort not found in UniPorts: ignore and continuing on checking further flows", |
| log.Fields{"device-id": dh.deviceID, "inPort": flowInPort}) |
| retError = fmt.Errorf("flow-remove inPort not found in UniPorts, inPort %d, device-id %s", |
| flowInPort, dh.deviceID) |
| continue |
| } |
| flowOutPort := flow.GetOutPort(flowItem) |
| logger.Debugw(ctx, "flow-remove port indications", log.Fields{ |
| "device-id": dh.deviceID, "inPort": flowInPort, "outPort": flowOutPort, |
| "uniPortName": loUniPort.name}) |
| err := dh.removeFlowItemFromUniPort(ctx, flowItem, loUniPort) |
| //try next flow after processing error |
| if err != nil { |
| logger.Warnw(ctx, "flow-remove processing error: continuing on checking further flows", |
| log.Fields{"device-id": dh.deviceID, "error": err}) |
| retError = err |
| continue |
| //return err |
| } else { // if last setting succeeds, overwrite possibly previously set error |
| retError = nil |
| } |
| } |
| } |
| } |
| if apOfFlowChanges.ToAdd != nil { |
| for _, flowItem := range apOfFlowChanges.ToAdd.Items { |
| if flowItem.GetCookie() == 0 { |
| logger.Debugw(ctx, "incremental flow-add no cookie: ignore and continuing on checking further flows", log.Fields{ |
| "device-id": dh.deviceID}) |
| retError = fmt.Errorf("flow-add no cookie, device-id %s", dh.deviceID) |
| continue |
| } |
| flowInPort := flow.GetInPort(flowItem) |
| if flowInPort == uint32(of.OfpPortNo_OFPP_INVALID) { |
| logger.Warnw(ctx, "flow-add inPort invalid: ignore and continuing on checking further flows", log.Fields{"device-id": dh.deviceID}) |
| retError = fmt.Errorf("flow-add inPort invalid, device-id %s", dh.deviceID) |
| continue |
| //return fmt.Errorf("flow inPort invalid: %s", dh.deviceID) |
| } else if flowInPort == dh.ponPortNumber { |
| //this is some downstream flow |
| logger.Debugw(ctx, "flow-add for downstream: ignore and continuing on checking further flows", log.Fields{ |
| "device-id": dh.deviceID, "inPort": flowInPort}) |
| continue |
| } else { |
| // this is the relevant upstream flow |
| var loUniPort *onuUniPort |
| if uniPort, exist := dh.uniEntityMap[flowInPort]; exist { |
| loUniPort = uniPort |
| } else { |
| logger.Warnw(ctx, "flow-add inPort not found in UniPorts: ignore and continuing on checking further flows", |
| log.Fields{"device-id": dh.deviceID, "inPort": flowInPort}) |
| retError = fmt.Errorf("flow-add inPort not found in UniPorts, inPort %d, device-id %s", |
| flowInPort, dh.deviceID) |
| continue |
| //return fmt.Errorf("flow-parameter inPort %d not found in internal UniPorts", flowInPort) |
| } |
| // let's still assume that we receive the flow-add only in some 'active' device state (as so far observed) |
| // if not, we just throw some error here to have an indication about that, if we really need to support that |
| // then we would need to create some means to activate the internal stored flows |
| // after the device gets active automatically (and still with its dependency to the TechProfile) |
| // for state checking compare also code here: processInterAdapterTechProfileDownloadReqMessage |
| // also abort for the other still possible flows here |
| if !dh.ReadyForSpecificOmciConfig { |
| logger.Errorw(ctx, "flow-add rejected: improper device state", log.Fields{"device-id": dh.deviceID, |
| "last device-reason": deviceReasonMap[dh.deviceReason]}) |
| return fmt.Errorf("improper device state on device %s", dh.deviceID) |
| } |
| |
| flowOutPort := flow.GetOutPort(flowItem) |
| logger.Debugw(ctx, "flow-add port indications", log.Fields{ |
| "device-id": dh.deviceID, "inPort": flowInPort, "outPort": flowOutPort, |
| "uniPortName": loUniPort.name}) |
| err := dh.addFlowItemToUniPort(ctx, flowItem, loUniPort) |
| //try next flow after processing error |
| if err != nil { |
| logger.Warnw(ctx, "flow-add processing error: continuing on checking further flows", |
| log.Fields{"device-id": dh.deviceID, "error": err}) |
| retError = err |
| continue |
| //return err |
| } else { // if last setting succeeds, overwrite possibly previously set error |
| retError = nil |
| } |
| } |
| } |
| } |
| return retError |
| } |
| |
| //disableDevice locks the ONU and its UNI/VEIP ports (admin lock via OMCI) |
| //following are the expected device states after this activity: |
| //Device Admin-State : down (on rwCore), Port-State: UNKNOWN, Conn-State: REACHABLE, Reason: omci-admin-lock |
| // (Conn-State: REACHABLE might conflict with some previous ONU Down indication - maybe to be resolved later) |
| func (dh *deviceHandler) disableDevice(ctx context.Context, device *voltha.Device) { |
| logger.Debugw(ctx, "disable-device", log.Fields{"device-id": device.Id, "SerialNumber": device.SerialNumber}) |
| |
| //admin-lock reason can also be used uniquely for setting the DeviceState accordingly |
| //note that disableDevice sequences in some 'ONU active' state may yield also |
| // "tech...delete-success" or "omci-flow-deleted" according to further received requests in the end |
| // - inblock state checking to prevent possibly unneeded processing (on command repitition) |
| if dh.deviceReason != drOmciAdminLock { |
| //disable-device shall be just a UNi/ONU-G related admin state setting |
| //all other configurations/FSM's shall not be impacted and shall execute as required by the system |
| |
| if dh.ReadyForSpecificOmciConfig { |
| // disable UNI ports/ONU |
| // *** should generate UniDisableStateDone event - used to disable the port(s) on success |
| if dh.pLockStateFsm == nil { |
| dh.createUniLockFsm(ctx, true, UniDisableStateDone) |
| } else { //LockStateFSM already init |
| dh.pLockStateFsm.setSuccessEvent(UniDisableStateDone) |
| dh.runUniLockFsm(ctx, true) |
| } |
| } else { |
| logger.Debugw(ctx, "DeviceStateUpdate upon disable", log.Fields{"ConnectStatus": voltha.ConnectStatus_REACHABLE, |
| "OperStatus": voltha.OperStatus_UNKNOWN, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), |
| dh.deviceID, voltha.ConnectStatus_REACHABLE, voltha.OperStatus_UNKNOWN); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state", log.Fields{"device-id": dh.deviceID, "error": err}) |
| } |
| // DeviceReason to update acc.to modified py code as per beginning of Sept 2020 |
| |
| //TODO with VOL-3045/VOL-3046: catch and return error, valid for all occurrences in the codebase |
| _ = dh.deviceReasonUpdate(ctx, drOmciAdminLock, true) |
| } |
| } |
| } |
| |
| //reEnableDevice unlocks the ONU and its UNI/VEIP ports (admin unlock via OMCI) |
| func (dh *deviceHandler) reEnableDevice(ctx context.Context, device *voltha.Device) { |
| logger.Debugw(ctx, "reenable-device", log.Fields{"device-id": device.Id, "SerialNumber": device.SerialNumber}) |
| |
| //setting ReadyForSpecificOmciConfig here is just a workaround for BBSIM testing in the sequence |
| // OnuSoftReboot-disable-enable, because BBSIM does not generate a new OnuIndication-Up event after SoftReboot |
| // which is the assumption for real ONU's, where the ready-state is then set according to the following MibUpload/Download |
| // for real ONU's that should have nearly no influence |
| // Note that for real ONU's there is anyway a problematic situation with following sequence: |
| // OnuIndication-Dw (or not active at all) (- disable) - enable: here already the LockFsm may run into timeout (no OmciResponse) |
| // but that anyway is hopefully resolved by some OnuIndication-Up event (maybe to be tested) |
| // one could also argue, that a device-enable should also enable attempts for specific omci configuration |
| dh.ReadyForSpecificOmciConfig = true //needed to allow subsequent flow/techProf config (on BBSIM) |
| |
| // enable ONU/UNI ports |
| // *** should generate UniEnableStateDone event - used to disable the port(s) on success |
| if dh.pUnlockStateFsm == nil { |
| dh.createUniLockFsm(ctx, false, UniEnableStateDone) |
| } else { //UnlockStateFSM already init |
| dh.pUnlockStateFsm.setSuccessEvent(UniEnableStateDone) |
| dh.runUniLockFsm(ctx, false) |
| } |
| } |
| |
| func (dh *deviceHandler) reconcileDeviceOnuInd(ctx context.Context) { |
| logger.Debugw(ctx, "reconciling - simulate onu indication", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| if err := pDevEntry.restoreDataFromOnuKvStore(log.WithSpanFromContext(context.TODO(), ctx)); err != nil { |
| if err == fmt.Errorf("no-ONU-data-found") { |
| logger.Debugw(ctx, "no persistent data found - abort reconciling", log.Fields{"device-id": dh.deviceID}) |
| } else { |
| logger.Errorw(ctx, "reconciling - restoring OnuTp-data failed - abort", log.Fields{"err": err, "device-id": dh.deviceID}) |
| } |
| dh.reconciling = false |
| return |
| } |
| var onuIndication oop.OnuIndication |
| onuIndication.IntfId = pDevEntry.sOnuPersistentData.PersIntfID |
| onuIndication.OnuId = pDevEntry.sOnuPersistentData.PersOnuID |
| onuIndication.OperState = pDevEntry.sOnuPersistentData.PersOperState |
| onuIndication.AdminState = pDevEntry.sOnuPersistentData.PersAdminState |
| _ = dh.createInterface(ctx, &onuIndication) |
| } |
| |
| func (dh *deviceHandler) reconcileDeviceTechProf(ctx context.Context) { |
| logger.Debugw(ctx, "reconciling - trigger tech profile config", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| dh.pOnuTP.lockTpProcMutex() |
| defer dh.pOnuTP.unlockTpProcMutex() |
| |
| if len(pDevEntry.sOnuPersistentData.PersUniConfig) == 0 { |
| logger.Debugw(ctx, "reconciling - no uni-configs have been stored before adapter restart - terminate reconcilement", |
| log.Fields{"device-id": dh.deviceID}) |
| dh.reconciling = false |
| return |
| } |
| for _, uniData := range pDevEntry.sOnuPersistentData.PersUniConfig { |
| //TODO: check for uni-port specific reconcilement in case of multi-uni-port-per-onu-support |
| if len(uniData.PersTpPathMap) == 0 { |
| logger.Debugw(ctx, "reconciling - no TPs have been stored before adapter restart - terminate reconcilement", |
| log.Fields{"uni-id": uniData.PersUniID, "device-id": dh.deviceID}) |
| dh.reconciling = false |
| return |
| } |
| for tpID := range uniData.PersTpPathMap { |
| // deadline context to ensure completion of background routines waited for |
| //20200721: 10s proved to be less in 8*8 ONU test on local vbox machine with debug, might be further adapted |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(ctx, deadline) |
| |
| dh.pOnuTP.resetTpProcessingErrorIndication(uniData.PersUniID, tpID) |
| var wg sync.WaitGroup |
| wg.Add(1) // for the 1 go routine to finish |
| go dh.pOnuTP.configureUniTp(log.WithSpanFromContext(dctx, ctx), uniData.PersUniID, uniData.PersTpPathMap[tpID], &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "TechProfReconcile") //wait for background process to finish |
| if err := dh.pOnuTP.getTpProcessingErrorIndication(uniData.PersUniID, tpID); err != nil { |
| logger.Errorw(ctx, err.Error(), log.Fields{"device-id": dh.deviceID}) |
| } |
| } |
| if len(uniData.PersFlowParams) == 0 { |
| logger.Debugw(ctx, "reconciling - no flows have been stored before adapter restart - terminate reconcilement", |
| log.Fields{"uni-id": uniData.PersUniID, "device-id": dh.deviceID}) |
| dh.reconciling = false |
| } |
| } |
| } |
| |
| func (dh *deviceHandler) reconcileDeviceFlowConfig(ctx context.Context) { |
| logger.Debugw(ctx, "reconciling - trigger flow config", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| if len(pDevEntry.sOnuPersistentData.PersUniConfig) == 0 { |
| logger.Debugw(ctx, "reconciling - no uni-configs have been stored before adapter restart - terminate reconcilement", |
| log.Fields{"device-id": dh.deviceID}) |
| dh.reconciling = false |
| return |
| } |
| for _, uniData := range pDevEntry.sOnuPersistentData.PersUniConfig { |
| //TODO: check for uni-port specific reconcilement in case of multi-uni-port-per-onu-support |
| if len(uniData.PersFlowParams) == 0 { |
| logger.Debugw(ctx, "reconciling - no flows have been stored before adapter restart - terminate reconcilement", |
| log.Fields{"uni-id": uniData.PersUniID, "device-id": dh.deviceID}) |
| dh.reconciling = false |
| return |
| } |
| var uniPort *onuUniPort |
| var exist bool |
| uniNo := mkUniPortNum(ctx, dh.pOnuIndication.GetIntfId(), dh.pOnuIndication.GetOnuId(), uint32(uniData.PersUniID)) |
| if uniPort, exist = dh.uniEntityMap[uniNo]; !exist { |
| logger.Errorw(ctx, "onuUniPort data not found!", log.Fields{"uniNo": uniNo, "device-id": dh.deviceID}) |
| return |
| } |
| for _, flowData := range uniData.PersFlowParams { |
| logger.Debugw(ctx, "add flow with cookie slice", log.Fields{"device-id": dh.deviceID, "cookies": flowData.CookieSlice}) |
| //the slice can be passed 'by value' here, - which internally passes its reference copy |
| if _, exist = dh.UniVlanConfigFsmMap[uniData.PersUniID]; exist { |
| if err := dh.UniVlanConfigFsmMap[uniData.PersUniID].SetUniFlowParams(ctx, flowData.VlanRuleParams.TpID, |
| flowData.CookieSlice, uint16(flowData.VlanRuleParams.MatchVid), uint16(flowData.VlanRuleParams.SetVid), |
| uint8(flowData.VlanRuleParams.SetPcp)); err != nil { |
| logger.Errorw(ctx, err.Error(), log.Fields{"device-id": dh.deviceID}) |
| } |
| } else { |
| if err := dh.createVlanFilterFsm(ctx, uniPort, flowData.VlanRuleParams.TpID, flowData.CookieSlice, |
| uint16(flowData.VlanRuleParams.MatchVid), uint16(flowData.VlanRuleParams.SetVid), |
| uint8(flowData.VlanRuleParams.SetPcp), OmciVlanFilterAddDone); err != nil { |
| logger.Errorw(ctx, err.Error(), log.Fields{"device-id": dh.deviceID}) |
| } |
| } |
| } |
| if len(uniData.PersTpPathMap) == 0 { |
| logger.Debugw(ctx, "reconciling - no TPs have been stored before adapter restart - terminate reconcilement", |
| log.Fields{"uni-id": uniData.PersUniID, "device-id": dh.deviceID}) |
| dh.reconciling = false |
| } |
| } |
| } |
| |
| func (dh *deviceHandler) reconcileMetrics(ctx context.Context) { |
| logger.Debugw(ctx, "reconciling - trigger metrics - to be implemented in scope of VOL-3324!", log.Fields{"device-id": dh.deviceID}) |
| |
| //TODO: reset of reconciling-flag has always to be done in the last reconcile*() function |
| dh.reconciling = false |
| } |
| |
| func (dh *deviceHandler) deleteDevicePersistencyData(ctx context.Context) error { |
| logger.Debugw(ctx, "delete device persistency data", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| //IfDevEntry does not exist here, no problem - no persistent data should have been stored |
| logger.Debugw(ctx, "OnuDevice does not exist - nothing to delete", log.Fields{"device-id": dh.deviceID}) |
| return nil |
| } |
| pDevEntry.lockOnuKVStoreMutex() |
| defer pDevEntry.unlockOnuKVStoreMutex() |
| |
| // deadline context to ensure completion of background routines waited for |
| //20200721: 10s proved to be less in 8*8 ONU test on local vbox machine with debug, might be further adapted |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(ctx, deadline) |
| |
| pDevEntry.resetKvProcessingErrorIndication() |
| |
| var wg sync.WaitGroup |
| wg.Add(1) // for the 1 go routine to finish |
| go pDevEntry.deleteDataFromOnuKvStore(log.WithSpanFromContext(dctx, ctx), &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "DeleteDevice") //wait for background process to finish |
| |
| // TODO: further actions - stop metrics and FSMs, remove device ... |
| return pDevEntry.getKvProcessingErrorIndication() |
| } |
| |
| func (dh *deviceHandler) rebootDevice(ctx context.Context, device *voltha.Device) error { |
| logger.Debugw(ctx, "reboot-device", log.Fields{"device-id": device.Id, "SerialNumber": device.SerialNumber}) |
| if device.ConnectStatus != voltha.ConnectStatus_REACHABLE { |
| logger.Errorw(ctx, "device-unreachable", log.Fields{"device-id": device.Id, "SerialNumber": device.SerialNumber}) |
| return fmt.Errorf("device-unreachable: %s, %s", dh.deviceID, device.SerialNumber) |
| } |
| if err := dh.pOnuOmciDevice.reboot(log.WithSpanFromContext(context.TODO(), ctx)); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-rebooting-device", log.Fields{"device-id": dh.deviceID, "error": err}) |
| return err |
| } |
| |
| //transfer the possibly modified logical uni port state |
| dh.disableUniPortStateUpdate(ctx) |
| |
| logger.Debugw(ctx, "call DeviceStateUpdate upon reboot", log.Fields{"ConnectStatus": voltha.ConnectStatus_REACHABLE, |
| "OperStatus": voltha.OperStatus_DISCOVERED, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, voltha.ConnectStatus_REACHABLE, |
| voltha.OperStatus_DISCOVERED); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state", log.Fields{"device-id": dh.deviceID, "error": err}) |
| return err |
| } |
| if err := dh.deviceReasonUpdate(ctx, drRebooting, true); err != nil { |
| return err |
| } |
| dh.ReadyForSpecificOmciConfig = false |
| //no specific activity to synchronize any internal FSM to the 'rebooted' state is explicitly done here |
| // the expectation ids for a real device, that it will be synced with the expected following 'down' indication |
| // as BBSIM does not support this testing requires explicite disable/enable device calls in which sequence also |
| // all other FSM's should be synchronized again |
| return nil |
| } |
| |
| // deviceHandler methods that implement the adapters interface requests## end ######### |
| // ##################################################################################### |
| |
| // ################ to be updated acc. needs of ONU Device ######################## |
| // deviceHandler StateMachine related state transition methods ##### begin ######### |
| |
| func (dh *deviceHandler) logStateChange(ctx context.Context, e *fsm.Event) { |
| logger.Debugw(ctx, "Device FSM: ", log.Fields{"event name": string(e.Event), "src state": string(e.Src), "dst state": string(e.Dst), "device-id": dh.deviceID}) |
| } |
| |
| // doStateInit provides the device update to the core |
| func (dh *deviceHandler) doStateInit(ctx context.Context, e *fsm.Event) { |
| |
| logger.Debug(ctx, "doStateInit-started") |
| var err error |
| |
| // populate what we know. rest comes later after mib sync |
| dh.device.Root = false |
| dh.device.Vendor = "OpenONU" |
| dh.device.Model = "go" |
| dh.device.Reason = deviceReasonMap[drActivatingOnu] |
| dh.deviceReason = drActivatingOnu |
| |
| dh.logicalDeviceID = dh.deviceID // really needed - what for ??? //TODO!!! |
| |
| if !dh.reconciling { |
| logger.Infow(ctx, "DeviceUpdate", log.Fields{"deviceReason": dh.device.Reason, "device-id": dh.deviceID}) |
| _ = dh.coreProxy.DeviceUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.device) |
| } else { |
| logger.Debugw(ctx, "reconciling - don't notify core about DeviceUpdate", |
| log.Fields{"device-id": dh.deviceID}) |
| } |
| |
| dh.parentID = dh.device.ParentId |
| dh.ponPortNumber = dh.device.ParentPortNo |
| |
| // store proxy parameters for later communication - assumption: invariant, else they have to be requested dynamically!! |
| dh.ProxyAddressID = dh.device.ProxyAddress.GetDeviceId() |
| dh.ProxyAddressType = dh.device.ProxyAddress.GetDeviceType() |
| logger.Debugw(ctx, "device-updated", log.Fields{"device-id": dh.deviceID, "proxyAddressID": dh.ProxyAddressID, |
| "proxyAddressType": dh.ProxyAddressType, "SNR": dh.device.SerialNumber, |
| "ParentId": dh.parentID, "ParentPortNo": dh.ponPortNumber}) |
| |
| /* |
| self._pon = PonPort.create(self, self._pon_port_number) |
| self._pon.add_peer(self.parent_id, self._pon_port_number) |
| self.logger.debug('adding-pon-port-to-agent', |
| type=self._pon.get_port().type, |
| admin_state=self._pon.get_port().admin_state, |
| oper_status=self._pon.get_port().oper_status, |
| ) |
| */ |
| if !dh.reconciling { |
| logger.Debugw(ctx, "adding-pon-port", log.Fields{"device-id": dh.deviceID, "ponPortNo": dh.ponPortNumber}) |
| var ponPortNo uint32 = 1 |
| if dh.ponPortNumber != 0 { |
| ponPortNo = dh.ponPortNumber |
| } |
| |
| pPonPort := &voltha.Port{ |
| PortNo: ponPortNo, |
| Label: fmt.Sprintf("pon-%d", ponPortNo), |
| Type: voltha.Port_PON_ONU, |
| OperStatus: voltha.OperStatus_ACTIVE, |
| Peers: []*voltha.Port_PeerPort{{DeviceId: dh.parentID, // Peer device is OLT |
| PortNo: ponPortNo}}, // Peer port is parent's port number |
| } |
| if err = dh.coreProxy.PortCreated(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, pPonPort); err != nil { |
| logger.Fatalf(ctx, "Device FSM: PortCreated-failed-%s", err) |
| e.Cancel(err) |
| return |
| } |
| } else { |
| logger.Debugw(ctx, "reconciling - pon-port already added", log.Fields{"device-id": dh.deviceID}) |
| } |
| logger.Debug(ctx, "doStateInit-done") |
| } |
| |
| // postInit setups the DeviceEntry for the conerned device |
| func (dh *deviceHandler) postInit(ctx context.Context, e *fsm.Event) { |
| |
| logger.Debug(ctx, "postInit-started") |
| var err error |
| /* |
| dh.Client = oop.NewOpenoltClient(dh.clientCon) |
| dh.pTransitionMap.Handle(ctx, GrpcConnected) |
| return nil |
| */ |
| if err = dh.addOnuDeviceEntry(log.WithSpanFromContext(context.TODO(), ctx)); err != nil { |
| logger.Fatalf(ctx, "Device FSM: addOnuDeviceEntry-failed-%s", err) |
| e.Cancel(err) |
| return |
| } |
| |
| if dh.reconciling { |
| go dh.reconcileDeviceOnuInd(ctx) |
| // reconcilement will be continued after mib download is done |
| } |
| /* |
| ############################################################################ |
| # Setup Alarm handler |
| self.events = AdapterEvents(self.core_proxy, device.id, self.logical_device_id, |
| device.serial_number) |
| ############################################################################ |
| # Setup PM configuration for this device |
| # Pass in ONU specific options |
| kwargs = { |
| OnuPmMetrics.DEFAULT_FREQUENCY_KEY: OnuPmMetrics.DEFAULT_ONU_COLLECTION_FREQUENCY, |
| 'heartbeat': self.heartbeat, |
| OnuOmciPmMetrics.OMCI_DEV_KEY: self._onu_omci_device |
| } |
| self.logger.debug('create-pm-metrics', device_id=device.id, serial_number=device.serial_number) |
| self._pm_metrics = OnuPmMetrics(self.events, self.core_proxy, self.device_id, |
| self.logical_device_id, device.serial_number, |
| grouped=True, freq_override=False, **kwargs) |
| pm_config = self._pm_metrics.make_proto() |
| self._onu_omci_device.set_pm_config(self._pm_metrics.omci_pm.openomci_interval_pm) |
| self.logger.info("initial-pm-config", device_id=device.id, serial_number=device.serial_number) |
| yield self.core_proxy.device_pm_config_update(pm_config, init=True) |
| |
| # Note, ONU ID and UNI intf set in add_uni_port method |
| self._onu_omci_device.alarm_synchronizer.set_alarm_params(mgr=self.events, |
| ani_ports=[self._pon]) |
| |
| # Code to Run OMCI Test Action |
| kwargs_omci_test_action = { |
| OmciTestRequest.DEFAULT_FREQUENCY_KEY: |
| OmciTestRequest.DEFAULT_COLLECTION_FREQUENCY |
| } |
| serial_number = device.serial_number |
| self._test_request = OmciTestRequest(self.core_proxy, |
| self.omci_agent, self.device_id, |
| AniG, serial_number, |
| self.logical_device_id, |
| exclusive=False, |
| **kwargs_omci_test_action) |
| |
| self.enabled = True |
| else: |
| self.logger.info('onu-already-activated') |
| */ |
| logger.Debug(ctx, "postInit-done") |
| } |
| |
| // doStateConnected get the device info and update to voltha core |
| // for comparison of the original method (not that easy to uncomment): compare here: |
| // voltha-openolt-adapter/adaptercore/device_handler.go |
| // -> this one obviously initiates all communication interfaces of the device ...? |
| func (dh *deviceHandler) doStateConnected(ctx context.Context, e *fsm.Event) { |
| |
| logger.Debug(ctx, "doStateConnected-started") |
| err := errors.New("device FSM: function not implemented yet") |
| e.Cancel(err) |
| logger.Debug(ctx, "doStateConnected-done") |
| } |
| |
| // doStateUp handle the onu up indication and update to voltha core |
| func (dh *deviceHandler) doStateUp(ctx context.Context, e *fsm.Event) { |
| |
| logger.Debug(ctx, "doStateUp-started") |
| err := errors.New("device FSM: function not implemented yet") |
| e.Cancel(err) |
| logger.Debug(ctx, "doStateUp-done") |
| |
| /* |
| // Synchronous call to update device state - this method is run in its own go routine |
| if err := dh.coreProxy.DeviceStateUpdate(ctx, dh.device.Id, voltha.ConnectStatus_REACHABLE, |
| voltha.OperStatus_ACTIVE); err != nil { |
| logger.Errorw("Failed to update device with OLT UP indication", log.Fields{"device-id": dh.device.Id, "error": err}) |
| return err |
| } |
| return nil |
| */ |
| } |
| |
| // doStateDown handle the onu down indication |
| func (dh *deviceHandler) doStateDown(ctx context.Context, e *fsm.Event) { |
| |
| logger.Debug(ctx, "doStateDown-started") |
| var err error |
| |
| device := dh.device |
| if device == nil { |
| /*TODO: needs to handle error scenarios */ |
| logger.Errorw(ctx, "Failed to fetch handler device", log.Fields{"device-id": dh.deviceID}) |
| e.Cancel(err) |
| return |
| } |
| |
| cloned := proto.Clone(device).(*voltha.Device) |
| logger.Debugw(ctx, "do-state-down", log.Fields{"ClonedDeviceID": cloned.Id}) |
| /* |
| // Update the all ports state on that device to disable |
| if er := dh.coreProxy.PortsStateUpdate(ctx, cloned.Id, voltha.OperStatus_UNKNOWN); er != nil { |
| logger.Errorw("updating-ports-failed", log.Fields{"device-id": device.Id, "error": er}) |
| return er |
| } |
| |
| //Update the device oper state and connection status |
| cloned.OperStatus = voltha.OperStatus_UNKNOWN |
| cloned.ConnectStatus = common.ConnectStatus_UNREACHABLE |
| dh.device = cloned |
| |
| if er := dh.coreProxy.DeviceStateUpdate(ctx, cloned.Id, cloned.ConnectStatus, cloned.OperStatus); er != nil { |
| logger.Errorw("error-updating-device-state", log.Fields{"device-id": device.Id, "error": er}) |
| return er |
| } |
| |
| //get the child device for the parent device |
| onuDevices, err := dh.coreProxy.GetChildDevices(ctx, dh.device.Id) |
| if err != nil { |
| logger.Errorw("failed to get child devices information", log.Fields{"device-id": dh.device.Id, "error": err}) |
| return err |
| } |
| for _, onuDevice := range onuDevices.Items { |
| |
| // Update onu state as down in onu adapter |
| onuInd := oop.OnuIndication{} |
| onuInd.OperState = "down" |
| er := dh.AdapterProxy.SendInterAdapterMessage(ctx, &onuInd, ic.InterAdapterMessageType_ONU_IND_REQUEST, |
| "openolt", onuDevice.Type, onuDevice.Id, onuDevice.ProxyAddress.DeviceId, "") |
| if er != nil { |
| logger.Errorw("Failed to send inter-adapter-message", log.Fields{"OnuInd": onuInd, |
| "From Adapter": "openolt", "DevieType": onuDevice.Type, "device-id": onuDevice.Id}) |
| //Do not return here and continue to process other ONUs |
| } |
| } |
| // * Discovered ONUs entries need to be cleared , since after OLT |
| // is up, it starts sending discovery indications again* / |
| dh.discOnus = sync.Map{} |
| logger.Debugw("do-state-down-end", log.Fields{"device-id": device.Id}) |
| return nil |
| */ |
| err = errors.New("device FSM: function not implemented yet") |
| e.Cancel(err) |
| logger.Debug(ctx, "doStateDown-done") |
| } |
| |
| // deviceHandler StateMachine related state transition methods ##### end ######### |
| // ################################################################################# |
| |
| // ################################################### |
| // deviceHandler utility methods ##### begin ######### |
| |
| //getOnuDeviceEntry gets the ONU device entry and may wait until its value is defined |
| func (dh *deviceHandler) getOnuDeviceEntry(ctx context.Context, aWait bool) *OnuDeviceEntry { |
| dh.lockDevice.RLock() |
| pOnuDeviceEntry := dh.pOnuOmciDevice |
| if aWait && pOnuDeviceEntry == nil { |
| //keep the read sema short to allow for subsequent write |
| dh.lockDevice.RUnlock() |
| logger.Debugw(ctx, "Waiting for DeviceEntry to be set ...", log.Fields{"device-id": dh.deviceID}) |
| // based on concurrent processing the deviceEntry setup may not yet be finished at his point |
| // so it might be needed to wait here for that event with some timeout |
| select { |
| case <-time.After(60 * time.Second): //timer may be discussed ... |
| logger.Errorw(ctx, "No valid DeviceEntry set after maxTime", log.Fields{"device-id": dh.deviceID}) |
| return nil |
| case <-dh.deviceEntrySet: |
| logger.Debugw(ctx, "devicEntry ready now - continue", log.Fields{"device-id": dh.deviceID}) |
| // if written now, we can return the written value without sema |
| return dh.pOnuOmciDevice |
| } |
| } |
| dh.lockDevice.RUnlock() |
| return pOnuDeviceEntry |
| } |
| |
| //setOnuDeviceEntry sets the ONU device entry within the handler |
| func (dh *deviceHandler) setOnuDeviceEntry( |
| apDeviceEntry *OnuDeviceEntry, apOnuTp *onuUniTechProf) { |
| dh.lockDevice.Lock() |
| defer dh.lockDevice.Unlock() |
| dh.pOnuOmciDevice = apDeviceEntry |
| dh.pOnuTP = apOnuTp |
| } |
| |
| //addOnuDeviceEntry creates a new ONU device or returns the existing |
| func (dh *deviceHandler) addOnuDeviceEntry(ctx context.Context) error { |
| logger.Debugw(ctx, "adding-deviceEntry", log.Fields{"device-id": dh.deviceID}) |
| |
| deviceEntry := dh.getOnuDeviceEntry(ctx, false) |
| if deviceEntry == nil { |
| /* costum_me_map in python code seems always to be None, |
| we omit that here first (declaration unclear) -> todo at Adapter specialization ...*/ |
| /* also no 'clock' argument - usage open ...*/ |
| /* and no alarm_db yet (oo.alarm_db) */ |
| deviceEntry = newOnuDeviceEntry(ctx, dh) |
| onuTechProfProc := newOnuUniTechProf(ctx, dh) |
| //error treatment possible //TODO!!! |
| dh.setOnuDeviceEntry(deviceEntry, onuTechProfProc) |
| // fire deviceEntry ready event to spread to possibly waiting processing |
| dh.deviceEntrySet <- true |
| logger.Debugw(ctx, "onuDeviceEntry-added", log.Fields{"device-id": dh.deviceID}) |
| } else { |
| logger.Debugw(ctx, "onuDeviceEntry-add: Device already exists", log.Fields{"device-id": dh.deviceID}) |
| } |
| // might be updated with some error handling !!! |
| return nil |
| } |
| |
| func (dh *deviceHandler) createInterface(ctx context.Context, onuind *oop.OnuIndication) error { |
| logger.Debugw(ctx, "create_interface-started", log.Fields{"OnuId": onuind.GetOnuId(), |
| "OnuIntfId": onuind.GetIntfId(), "OnuSerialNumber": onuind.GetSerialNumber()}) |
| |
| dh.pOnuIndication = onuind // let's revise if storing the pointer is sufficient... |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| if !dh.reconciling { |
| if err := dh.storePersistentData(ctx); err != nil { |
| logger.Warnw(ctx, "store persistent data error - continue as there will be additional write attempts", |
| log.Fields{"device-id": dh.deviceID, "err": err}) |
| } |
| logger.Debugw(ctx, "call DeviceStateUpdate upon create interface", log.Fields{"ConnectStatus": voltha.ConnectStatus_REACHABLE, |
| "OperStatus": voltha.OperStatus_ACTIVATING, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, |
| voltha.ConnectStatus_REACHABLE, voltha.OperStatus_ACTIVATING); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state", log.Fields{"device-id": dh.deviceID, "error": err}) |
| } |
| } else { |
| logger.Debugw(ctx, "reconciling - don't notify core about DeviceStateUpdate to ACTIVATING", |
| log.Fields{"device-id": dh.deviceID}) |
| |
| if !pDevEntry.sOnuPersistentData.PersUniUnlockDone { |
| logger.Debugw(ctx, "reconciling - uni-ports were not unlocked before adapter restart - resume with a normal start-up", |
| log.Fields{"device-id": dh.deviceID}) |
| dh.reconciling = false |
| } |
| } |
| // It does not look to me as if makes sense to work with the real core device here, (not the stored clone)? |
| // in this code the GetDevice would just make a check if the DeviceID's Device still exists in core |
| // in python code it looks as the started onu_omci_device might have been updated with some new instance state of the core device |
| // but I would not know why, and the go code anyway does not work with the device directly anymore in the OnuDeviceEntry |
| // so let's just try to keep it simple ... |
| /* |
| device, err := dh.coreProxy.GetDevice(log.WithSpanFromContext(context.TODO(), ctx), dh.device.Id, dh.device.Id) |
| if err != nil || device == nil { |
| //TODO: needs to handle error scenarios |
| logger.Errorw("Failed to fetch device device at creating If", log.Fields{"err": err}) |
| return errors.New("Voltha Device not found") |
| } |
| */ |
| |
| if err := pDevEntry.start(log.WithSpanFromContext(context.TODO(), ctx)); err != nil { |
| return err |
| } |
| |
| _ = dh.deviceReasonUpdate(ctx, drStartingOpenomci, !dh.reconciling) |
| |
| /* this might be a good time for Omci Verify message? */ |
| verifyExec := make(chan bool) |
| omciVerify := newOmciTestRequest(log.WithSpanFromContext(context.TODO(), ctx), |
| dh.device.Id, pDevEntry.PDevOmciCC, |
| true, true) //exclusive and allowFailure (anyway not yet checked) |
| omciVerify.performOmciTest(log.WithSpanFromContext(context.TODO(), ctx), verifyExec) |
| |
| /* give the handler some time here to wait for the OMCi verification result |
| after Timeout start and try MibUpload FSM anyway |
| (to prevent stopping on just not supported OMCI verification from ONU) */ |
| select { |
| case <-time.After(2 * time.Second): |
| logger.Warn(ctx, "omci start-verification timed out (continue normal)") |
| case testresult := <-verifyExec: |
| logger.Infow(ctx, "Omci start verification done", log.Fields{"result": testresult}) |
| } |
| |
| /* In py code it looks earlier (on activate ..) |
| # Code to Run OMCI Test Action |
| kwargs_omci_test_action = { |
| OmciTestRequest.DEFAULT_FREQUENCY_KEY: |
| OmciTestRequest.DEFAULT_COLLECTION_FREQUENCY |
| } |
| serial_number = device.serial_number |
| self._test_request = OmciTestRequest(self.core_proxy, |
| self.omci_agent, self.device_id, |
| AniG, serial_number, |
| self.logical_device_id, |
| exclusive=False, |
| **kwargs_omci_test_action) |
| ... |
| # Start test requests after a brief pause |
| if not self._test_request_started: |
| self._test_request_started = True |
| tststart = _STARTUP_RETRY_WAIT * (random.randint(1, 5)) |
| reactor.callLater(tststart, self._test_request.start_collector) |
| |
| */ |
| /* which is then: in omci_test_request.py : */ |
| /* |
| def start_collector(self, callback=None): |
| """ |
| Start the collection loop for an adapter if the frequency > 0 |
| |
| :param callback: (callable) Function to call to collect PM data |
| """ |
| self.logger.info("starting-pm-collection", device_name=self.name, default_freq=self.default_freq) |
| if callback is None: |
| callback = self.perform_test_omci |
| |
| if self.lc is None: |
| self.lc = LoopingCall(callback) |
| |
| if self.default_freq > 0: |
| self.lc.start(interval=self.default_freq / 10) |
| |
| def perform_test_omci(self): |
| """ |
| Perform the initial test request |
| """ |
| ani_g_entities = self._device.configuration.ani_g_entities |
| ani_g_entities_ids = list(ani_g_entities.keys()) if ani_g_entities \ |
| is not None else None |
| self._entity_id = ani_g_entities_ids[0] |
| self.logger.info('perform-test', entity_class=self._entity_class, |
| entity_id=self._entity_id) |
| try: |
| frame = MEFrame(self._entity_class, self._entity_id, []).test() |
| result = yield self._device.omci_cc.send(frame) |
| if not result.fields['omci_message'].fields['success_code']: |
| self.logger.info('Self-Test Submitted Successfully', |
| code=result.fields[ |
| 'omci_message'].fields['success_code']) |
| else: |
| raise TestFailure('Test Failure: {}'.format( |
| result.fields['omci_message'].fields['success_code'])) |
| except TimeoutError as e: |
| self.deferred.errback(failure.Failure(e)) |
| |
| except Exception as e: |
| self.logger.exception('perform-test-Error', e=e, |
| class_id=self._entity_class, |
| entity_id=self._entity_id) |
| self.deferred.errback(failure.Failure(e)) |
| |
| */ |
| |
| // PM related heartbeat??? !!!TODO.... |
| //self._heartbeat.enabled = True |
| |
| /* Note: Even though FSM calls look 'synchronous' here, FSM is running in background with the effect that possible errors |
| * within the MibUpload are not notified in the OnuIndication response, this might be acceptable here, |
| * as further OltAdapter processing may rely on the deviceReason event 'MibUploadDone' as a result of the FSM processing |
| * otherwise some processing synchronization would be required - cmp. e.g TechProfile processing |
| */ |
| //call MibUploadFSM - transition up to state ulStInSync |
| pMibUlFsm := pDevEntry.pMibUploadFsm.pFsm |
| if pMibUlFsm != nil { |
| if pMibUlFsm.Is(ulStDisabled) { |
| if err := pMibUlFsm.Event(ulEvStart); err != nil { |
| logger.Errorw(ctx, "MibSyncFsm: Can't go to state starting", log.Fields{"device-id": dh.deviceID, "err": err}) |
| return fmt.Errorf("can't go to state starting: %s", dh.deviceID) |
| } |
| logger.Debugw(ctx, "MibSyncFsm", log.Fields{"state": string(pMibUlFsm.Current())}) |
| //Determine ONU status and start/re-start MIB Synchronization tasks |
| //Determine if this ONU has ever synchronized |
| if true { //TODO: insert valid check |
| if err := pMibUlFsm.Event(ulEvResetMib); err != nil { |
| logger.Errorw(ctx, "MibSyncFsm: Can't go to state resetting_mib", log.Fields{"device-id": dh.deviceID, "err": err}) |
| return fmt.Errorf("can't go to state resetting_mib: %s", dh.deviceID) |
| } |
| } else { |
| if err := pMibUlFsm.Event(ulEvExamineMds); err != nil { |
| logger.Errorw(ctx, "MibSyncFsm: Can't go to state examine_mds", log.Fields{"device-id": dh.deviceID, "err": err}) |
| return fmt.Errorf("can't go to examine_mds: %s", dh.deviceID) |
| } |
| logger.Debugw(ctx, "state of MibSyncFsm", log.Fields{"state": string(pMibUlFsm.Current())}) |
| //Examine the MIB Data Sync |
| // callbacks to be handled: |
| // Event(ulEvSuccess) |
| // Event(ulEvTimeout) |
| // Event(ulEvMismatch) |
| } |
| } else { |
| logger.Errorw(ctx, "wrong state of MibSyncFsm - want: disabled", log.Fields{"have": string(pMibUlFsm.Current()), |
| "device-id": dh.deviceID}) |
| return fmt.Errorf("wrong state of MibSyncFsm: %s", dh.deviceID) |
| } |
| } else { |
| logger.Errorw(ctx, "MibSyncFsm invalid - cannot be executed!!", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("can't execute MibSync: %s", dh.deviceID) |
| } |
| return nil |
| } |
| |
| func (dh *deviceHandler) updateInterface(ctx context.Context, onuind *oop.OnuIndication) error { |
| //state checking to prevent unneeded processing (eg. on ONU 'unreachable' and 'down') |
| // (but note that the deviceReason may also have changed to e.g. TechProf*Delete_Success in between) |
| if dh.deviceReason != drStoppingOpenomci { |
| logger.Debugw(ctx, "updateInterface-started - stopping-device", log.Fields{"device-id": dh.deviceID}) |
| |
| //stop all running FSM processing - make use of the DH-state as mirrored in the deviceReason |
| //here no conflict with aborted FSM's should arise as a complete OMCI initialization is assumed on ONU-Up |
| //but that might change with some simple MDS check on ONU-Up treatment -> attention!!! |
| if err := dh.resetFsms(ctx); err != nil { |
| logger.Errorw(ctx, "error-updateInterface at FSM stop", |
| log.Fields{"device-id": dh.deviceID, "error": err}) |
| // abort: system behavior is just unstable ... |
| return err |
| } |
| //all stored persistent data are not valid anymore (loosing knowledge about the connected ONU) |
| _ = dh.deleteDevicePersistencyData(ctx) //ignore possible errors here and continue, hope is that data is synchronized with new ONU-Up |
| |
| //deviceEntry stop without omciCC reset here, regarding the OMCI_CC still valid for this ONU |
| // - in contrary to disableDevice - compare with processUniDisableStateDoneEvent |
| //stop the device entry which resets the attached omciCC |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice -aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| _ = pDevEntry.stop(log.WithSpanFromContext(context.TODO(), ctx), false) |
| |
| //TODO!!! remove existing traffic profiles |
| /* from py code, if TP's exist, remove them - not yet implemented |
| self._tp = dict() |
| # Let TP download happen again |
| for uni_id in self._tp_service_specific_task: |
| self._tp_service_specific_task[uni_id].clear() |
| for uni_id in self._tech_profile_download_done: |
| self._tech_profile_download_done[uni_id].clear() |
| */ |
| |
| dh.disableUniPortStateUpdate(ctx) |
| |
| dh.ReadyForSpecificOmciConfig = false |
| |
| if err := dh.deviceReasonUpdate(ctx, drStoppingOpenomci, true); err != nil { |
| // abort: system behavior is just unstable ... |
| return err |
| } |
| logger.Debugw(ctx, "call DeviceStateUpdate upon update interface", log.Fields{"ConnectStatus": voltha.ConnectStatus_UNREACHABLE, |
| "OperStatus": voltha.OperStatus_DISCOVERED, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, |
| voltha.ConnectStatus_UNREACHABLE, voltha.OperStatus_DISCOVERED); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state unreachable-discovered", |
| log.Fields{"device-id": dh.deviceID, "error": err}) |
| // abort: system behavior is just unstable ... |
| return err |
| } |
| } else { |
| logger.Debugw(ctx, "updateInterface - device already stopped", log.Fields{"device-id": dh.deviceID}) |
| } |
| return nil |
| } |
| |
| func (dh *deviceHandler) resetFsms(ctx context.Context) error { |
| //all possible FSM's are stopped or reset here to ensure their transition to 'disabled' |
| //it is not sufficient to stop/reset the latest running FSM as done in previous versions |
| // as after down/up procedures all FSM's might be active/ongoing (in theory) |
| // and using the stop/reset event should never harm |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice -aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| //the MibSync FSM might be active all the ONU-active time, |
| // hence it must be stopped unconditionally |
| pMibUlFsm := pDevEntry.pMibUploadFsm.pFsm |
| if pMibUlFsm != nil { |
| _ = pMibUlFsm.Event(ulEvStop) //TODO!! verify if MibSyncFsm stop-processing is sufficient (to allow it again afterwards) |
| } |
| //MibDownload may run |
| pMibDlFsm := pDevEntry.pMibDownloadFsm.pFsm |
| if pMibDlFsm != nil { |
| _ = pMibDlFsm.Event(dlEvReset) |
| } |
| //port lock/unlock FSM's may be active |
| if dh.pUnlockStateFsm != nil { |
| _ = dh.pUnlockStateFsm.pAdaptFsm.pFsm.Event(uniEvReset) |
| } |
| if dh.pLockStateFsm != nil { |
| _ = dh.pLockStateFsm.pAdaptFsm.pFsm.Event(uniEvReset) |
| } |
| //techProfile related PonAniConfigFsm FSM may be active |
| if dh.pOnuTP != nil { |
| // should always be the case here |
| // FSM stop maybe encapsulated as OnuTP method - perhaps later in context of module splitting |
| if dh.pOnuTP.pAniConfigFsm != nil { |
| for uniTP := range dh.pOnuTP.pAniConfigFsm { |
| _ = dh.pOnuTP.pAniConfigFsm[uniTP].pAdaptFsm.pFsm.Event(aniEvReset) |
| } |
| } |
| for _, uniPort := range dh.uniEntityMap { |
| // reset the possibly existing VlanConfigFsm |
| if pVlanFilterFsm, exist := dh.UniVlanConfigFsmMap[uniPort.uniID]; exist { |
| //VlanFilterFsm exists and was already started |
| pVlanFilterStatemachine := pVlanFilterFsm.pAdaptFsm.pFsm |
| if pVlanFilterStatemachine != nil { |
| //reset of all Fsm is always accompanied by global persistency data removal |
| // no need to remove specific data |
| pVlanFilterFsm.RequestClearPersistency(false) |
| //and reset the UniVlanConfig FSM |
| _ = pVlanFilterStatemachine.Event(vlanEvReset) |
| } |
| } |
| } |
| } |
| //TODO!!! care about PM/Alarm processing once started |
| return nil |
| } |
| |
| func (dh *deviceHandler) processMibDatabaseSyncEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| logger.Debugw(ctx, "MibInSync event received, adding uni ports and locking the ONU interfaces", log.Fields{"device-id": dh.deviceID}) |
| |
| _ = dh.deviceReasonUpdate(ctx, drDiscoveryMibsyncComplete, !dh.reconciling) |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| i := uint8(0) //UNI Port limit: see MaxUnisPerOnu (by now 16) (OMCI supports max 255 p.b.) |
| if unigInstKeys := pDevEntry.pOnuDB.getSortedInstKeys(ctx, me.UniGClassID); len(unigInstKeys) > 0 { |
| for _, mgmtEntityID := range unigInstKeys { |
| logger.Debugw(ctx, "Add UNI port for stored UniG instance:", log.Fields{ |
| "device-id": dh.deviceID, "UnigMe EntityID": mgmtEntityID}) |
| dh.addUniPort(ctx, mgmtEntityID, i, uniPPTP) |
| i++ |
| } |
| } else { |
| logger.Debugw(ctx, "No UniG instances found", log.Fields{"device-id": dh.deviceID}) |
| } |
| if veipInstKeys := pDevEntry.pOnuDB.getSortedInstKeys(ctx, me.VirtualEthernetInterfacePointClassID); len(veipInstKeys) > 0 { |
| for _, mgmtEntityID := range veipInstKeys { |
| logger.Debugw(ctx, "Add VEIP acc. to stored VEIP instance:", log.Fields{ |
| "device-id": dh.deviceID, "VEIP EntityID": mgmtEntityID}) |
| dh.addUniPort(ctx, mgmtEntityID, i, uniVEIP) |
| i++ |
| } |
| } else { |
| logger.Debugw(ctx, "No VEIP instances found", log.Fields{"device-id": dh.deviceID}) |
| } |
| if i == 0 { |
| logger.Warnw(ctx, "No PPTP instances found", log.Fields{"device-id": dh.deviceID}) |
| } |
| /* 200605: lock processing after initial MIBUpload removed now as the ONU should be in the lock state per default here */ |
| /* 201117: build_dt-berlin-pod-openonugo_1T8GEM_voltha_DT_openonugo_master_test runs into error TC |
| * 'Test Disable ONUs and OLT Then Delete ONUs and OLT for DT' with Sercom ONU, which obviously needs |
| * disable/enable toggling here to allow traffic |
| * but moreover it might be useful for tracking the interface operState changes if this will be implemented, |
| * like the py comment says: |
| * # start by locking all the unis till mib sync and initial mib is downloaded |
| * # this way we can capture the port down/up events when we are ready |
| */ |
| |
| // Init Uni Ports to Admin locked state |
| // *** should generate UniLockStateDone event ***** |
| if dh.pLockStateFsm == nil { |
| dh.createUniLockFsm(ctx, true, UniLockStateDone) |
| } else { //LockStateFSM already init |
| dh.pLockStateFsm.setSuccessEvent(UniLockStateDone) |
| dh.runUniLockFsm(ctx, true) |
| } |
| } |
| |
| func (dh *deviceHandler) processUniLockStateDoneEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| logger.Infow(ctx, "UniLockStateDone event: Starting MIB download", log.Fields{"device-id": dh.deviceID}) |
| /* Mib download procedure - |
| ***** should run over 'downloaded' state and generate MibDownloadDone event ***** |
| */ |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice -aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| pMibDlFsm := pDevEntry.pMibDownloadFsm.pFsm |
| if pMibDlFsm != nil { |
| if pMibDlFsm.Is(dlStDisabled) { |
| if err := pMibDlFsm.Event(dlEvStart); err != nil { |
| logger.Errorw(ctx, "MibDownloadFsm: Can't go to state starting", log.Fields{"device-id": dh.deviceID, "err": err}) |
| // maybe try a FSM reset and then again ... - TODO!!! |
| } else { |
| logger.Debugw(ctx, "MibDownloadFsm", log.Fields{"state": string(pMibDlFsm.Current())}) |
| // maybe use more specific states here for the specific download steps ... |
| if err := pMibDlFsm.Event(dlEvCreateGal); err != nil { |
| logger.Errorw(ctx, "MibDownloadFsm: Can't start CreateGal", log.Fields{"device-id": dh.deviceID, "err": err}) |
| } else { |
| logger.Debugw(ctx, "state of MibDownloadFsm", log.Fields{"state": string(pMibDlFsm.Current())}) |
| //Begin MIB data download (running autonomously) |
| } |
| } |
| } else { |
| logger.Errorw(ctx, "wrong state of MibDownloadFsm - want: disabled", log.Fields{"have": string(pMibDlFsm.Current()), |
| "device-id": dh.deviceID}) |
| // maybe try a FSM reset and then again ... - TODO!!! |
| } |
| /***** Mib download started */ |
| } else { |
| logger.Errorw(ctx, "MibDownloadFsm invalid - cannot be executed!!", log.Fields{"device-id": dh.deviceID}) |
| } |
| } |
| |
| func (dh *deviceHandler) processMibDownloadDoneEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| logger.Debugw(ctx, "MibDownloadDone event received, unlocking the ONU interfaces", log.Fields{"device-id": dh.deviceID}) |
| //initiate DevStateUpdate |
| if !dh.reconciling { |
| logger.Debugw(ctx, "call DeviceStateUpdate upon mib-download done", log.Fields{"ConnectStatus": voltha.ConnectStatus_REACHABLE, |
| "OperStatus": voltha.OperStatus_ACTIVE, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, |
| voltha.ConnectStatus_REACHABLE, voltha.OperStatus_ACTIVE); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state", log.Fields{"device-id": dh.deviceID, "error": err}) |
| } else { |
| logger.Debugw(ctx, "dev state updated to 'Oper.Active'", log.Fields{"device-id": dh.deviceID}) |
| } |
| } else { |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| if pDevEntry.sOnuPersistentData.PersUniDisableDone { |
| logger.Debugw(ctx, "reconciling - uni-ports were disabled by admin before adapter restart - keep the ports locked and wait for re-enabling", |
| log.Fields{"device-id": dh.deviceID}) |
| dh.reconciling = false |
| return |
| } |
| logger.Debugw(ctx, "reconciling - don't notify core about DeviceStateUpdate to ACTIVE", |
| log.Fields{"device-id": dh.deviceID}) |
| } |
| _ = dh.deviceReasonUpdate(ctx, drInitialMibDownloaded, !dh.reconciling) |
| dh.ReadyForSpecificOmciConfig = true |
| // *** should generate UniUnlockStateDone event ***** |
| if dh.pUnlockStateFsm == nil { |
| dh.createUniLockFsm(ctx, false, UniUnlockStateDone) |
| } else { //UnlockStateFSM already init |
| dh.pUnlockStateFsm.setSuccessEvent(UniUnlockStateDone) |
| dh.runUniLockFsm(ctx, false) |
| } |
| } |
| |
| func (dh *deviceHandler) processUniUnlockStateDoneEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| dh.enableUniPortStateUpdate(ctx) //cmp python yield self.enable_ports() |
| |
| if !dh.reconciling { |
| logger.Infow(ctx, "UniUnlockStateDone event: Sending OnuUp event", log.Fields{"device-id": dh.deviceID}) |
| raisedTs := time.Now().UnixNano() |
| go dh.sendOnuOperStateEvent(ctx, voltha.OperStatus_ACTIVE, dh.deviceID, raisedTs) //cmp python onu_active_event |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| pDevEntry.sOnuPersistentData.PersUniUnlockDone = true |
| if err := dh.storePersistentData(ctx); err != nil { |
| logger.Warnw(ctx, "store persistent data error - continue for now as there will be additional write attempts", |
| log.Fields{"device-id": dh.deviceID, "err": err}) |
| } |
| } else { |
| logger.Debugw(ctx, "reconciling - don't notify core that onu went to active but trigger tech profile config", |
| log.Fields{"device-id": dh.deviceID}) |
| go dh.reconcileDeviceTechProf(ctx) |
| // reconcilement will be continued after ani config is done |
| } |
| } |
| |
| func (dh *deviceHandler) processUniDisableStateDoneEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| logger.Debugw(ctx, "DeviceStateUpdate upon disable", log.Fields{"ConnectStatus": voltha.ConnectStatus_REACHABLE, |
| "OperStatus": voltha.OperStatus_UNKNOWN, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), |
| dh.deviceID, voltha.ConnectStatus_REACHABLE, voltha.OperStatus_UNKNOWN); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state", log.Fields{"device-id": dh.deviceID, "error": err}) |
| } |
| |
| logger.Debugw(ctx, "DeviceReasonUpdate upon disable", log.Fields{"reason": deviceReasonMap[drOmciAdminLock], "device-id": dh.deviceID}) |
| // DeviceReason to update acc.to modified py code as per beginning of Sept 2020 |
| _ = dh.deviceReasonUpdate(ctx, drOmciAdminLock, true) |
| |
| //transfer the modified logical uni port state |
| dh.disableUniPortStateUpdate(ctx) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| pDevEntry.sOnuPersistentData.PersUniDisableDone = true |
| if err := dh.storePersistentData(ctx); err != nil { |
| logger.Warnw(ctx, "store persistent data error - continue for now as there will be additional write attempts", |
| log.Fields{"device-id": dh.deviceID, "err": err}) |
| } |
| } |
| |
| func (dh *deviceHandler) processUniEnableStateDoneEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| logger.Debugw(ctx, "DeviceStateUpdate upon re-enable", log.Fields{"ConnectStatus": voltha.ConnectStatus_REACHABLE, |
| "OperStatus": voltha.OperStatus_ACTIVE, "device-id": dh.deviceID}) |
| if err := dh.coreProxy.DeviceStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, voltha.ConnectStatus_REACHABLE, |
| voltha.OperStatus_ACTIVE); err != nil { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing |
| logger.Errorw(ctx, "error-updating-device-state", log.Fields{"device-id": dh.deviceID, "error": err}) |
| } |
| |
| logger.Debugw(ctx, "DeviceReasonUpdate upon re-enable", log.Fields{ |
| "reason": deviceReasonMap[drOnuReenabled], "device-id": dh.deviceID}) |
| // DeviceReason to update acc.to modified py code as per beginning of Sept 2020 |
| _ = dh.deviceReasonUpdate(ctx, drOnuReenabled, true) |
| |
| //transfer the modified logical uni port state |
| dh.enableUniPortStateUpdate(ctx) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, false) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| pDevEntry.sOnuPersistentData.PersUniDisableDone = false |
| if err := dh.storePersistentData(ctx); err != nil { |
| logger.Warnw(ctx, "store persistent data error - continue for now as there will be additional write attempts", |
| log.Fields{"device-id": dh.deviceID, "err": err}) |
| } |
| } |
| |
| func (dh *deviceHandler) processOmciAniConfigDoneEvent(ctx context.Context, devEvent OnuDeviceEvent) { |
| if devEvent == OmciAniConfigDone { |
| logger.Debugw(ctx, "OmciAniConfigDone event received", log.Fields{"device-id": dh.deviceID}) |
| // attention: the device reason update is done based on ONU-UNI-Port related activity |
| // - which may cause some inconsistency |
| if dh.deviceReason != drTechProfileConfigDownloadSuccess { |
| // which may be the case from some previous actvity even on this UNI Port (but also other UNI ports) |
| _ = dh.deviceReasonUpdate(ctx, drTechProfileConfigDownloadSuccess, !dh.reconciling) |
| } |
| if dh.reconciling { |
| go dh.reconcileDeviceFlowConfig(ctx) |
| } |
| } else { // should be the OmciAniResourceRemoved block |
| logger.Debugw(ctx, "OmciAniResourceRemoved event received", log.Fields{"device-id": dh.deviceID}) |
| // attention: the device reason update is done based on ONU-UNI-Port related activity |
| // - which may cause some inconsistency |
| if dh.deviceReason != drTechProfileConfigDeleteSuccess { |
| // which may be the case from some previous actvity even on this ONU port (but also other UNI ports) |
| _ = dh.deviceReasonUpdate(ctx, drTechProfileConfigDeleteSuccess, true) |
| } |
| } |
| } |
| |
| func (dh *deviceHandler) processOmciVlanFilterDoneEvent(ctx context.Context, aDevEvent OnuDeviceEvent) { |
| logger.Debugw(ctx, "OmciVlanFilterDone event received", |
| log.Fields{"device-id": dh.deviceID, "event": aDevEvent}) |
| // attention: the device reason update is done based on ONU-UNI-Port related activity |
| // - which may cause some inconsistency |
| |
| if aDevEvent == OmciVlanFilterAddDone { |
| if dh.deviceReason != drOmciFlowsPushed { |
| // which may be the case from some previous actvity on another UNI Port of the ONU |
| // or even some previous flow add activity on the same port |
| _ = dh.deviceReasonUpdate(ctx, drOmciFlowsPushed, !dh.reconciling) |
| if dh.reconciling { |
| go dh.reconcileMetrics(ctx) |
| } |
| } |
| } else { |
| if dh.deviceReason != drOmciFlowsDeleted { |
| //not relevant for reconcile |
| _ = dh.deviceReasonUpdate(ctx, drOmciFlowsDeleted, true) |
| } |
| } |
| } |
| |
| //deviceProcStatusUpdate evaluates possible processing events and initiates according next activities |
| func (dh *deviceHandler) deviceProcStatusUpdate(ctx context.Context, devEvent OnuDeviceEvent) { |
| switch devEvent { |
| case MibDatabaseSync: |
| { |
| dh.processMibDatabaseSyncEvent(ctx, devEvent) |
| } |
| case UniLockStateDone: |
| { |
| dh.processUniLockStateDoneEvent(ctx, devEvent) |
| } |
| case MibDownloadDone: |
| { |
| dh.processMibDownloadDoneEvent(ctx, devEvent) |
| } |
| case UniUnlockStateDone: |
| { |
| dh.processUniUnlockStateDoneEvent(ctx, devEvent) |
| } |
| case UniEnableStateDone: |
| { |
| dh.processUniEnableStateDoneEvent(ctx, devEvent) |
| } |
| case UniDisableStateDone: |
| { |
| dh.processUniDisableStateDoneEvent(ctx, devEvent) |
| } |
| case OmciAniConfigDone, OmciAniResourceRemoved: |
| { |
| dh.processOmciAniConfigDoneEvent(ctx, devEvent) |
| } |
| case OmciVlanFilterAddDone, OmciVlanFilterRemDone: |
| { |
| dh.processOmciVlanFilterDoneEvent(ctx, devEvent) |
| } |
| default: |
| { |
| logger.Debugw(ctx, "unhandled-device-event", log.Fields{"device-id": dh.deviceID, "event": devEvent}) |
| } |
| } //switch |
| } |
| |
| func (dh *deviceHandler) addUniPort(ctx context.Context, aUniInstNo uint16, aUniID uint8, aPortType uniPortType) { |
| // parameters are IntfId, OnuId, uniId |
| uniNo := mkUniPortNum(ctx, dh.pOnuIndication.GetIntfId(), dh.pOnuIndication.GetOnuId(), |
| uint32(aUniID)) |
| if _, present := dh.uniEntityMap[uniNo]; present { |
| logger.Warnw(ctx, "onuUniPort-add: Port already exists", log.Fields{"for InstanceId": aUniInstNo}) |
| } else { |
| //with arguments aUniID, a_portNo, aPortType |
| pUniPort := newOnuUniPort(ctx, aUniID, uniNo, aUniInstNo, aPortType) |
| if pUniPort == nil { |
| logger.Warnw(ctx, "onuUniPort-add: Could not create Port", log.Fields{"for InstanceId": aUniInstNo}) |
| } else { |
| //store UniPort with the System-PortNumber key |
| dh.uniEntityMap[uniNo] = pUniPort |
| if !dh.reconciling { |
| // create announce the UniPort to the core as VOLTHA Port object |
| if err := pUniPort.createVolthaPort(ctx, dh); err == nil { |
| logger.Infow(ctx, "onuUniPort-added", log.Fields{"for PortNo": uniNo}) |
| } //error logging already within UniPort method |
| } else { |
| logger.Debugw(ctx, "reconciling - onuUniPort already added", log.Fields{"for PortNo": uniNo, "device-id": dh.deviceID}) |
| } |
| } |
| } |
| } |
| |
| // enableUniPortStateUpdate enables UniPortState and update core port state accordingly |
| func (dh *deviceHandler) enableUniPortStateUpdate(ctx context.Context) { |
| // py code was updated 2003xx to activate the real ONU UNI ports per OMCI (VEIP or PPTP) |
| // but towards core only the first port active state is signaled |
| // with following remark: |
| // # TODO: for now only support the first UNI given no requirement for multiple uni yet. Also needed to reduce flow |
| // # load on the core |
| |
| // lock_ports(false) as done in py code here is shifted to separate call from devicevent processing |
| |
| for uniNo, uniPort := range dh.uniEntityMap { |
| // only if this port is validated for operState transfer |
| if (1<<uniPort.uniID)&activeUniPortStateUpdateMask == (1 << uniPort.uniID) { |
| logger.Infow(ctx, "onuUniPort-forced-OperState-ACTIVE", log.Fields{"for PortNo": uniNo}) |
| uniPort.setOperState(vc.OperStatus_ACTIVE) |
| if !dh.reconciling { |
| //maybe also use getter functions on uniPort - perhaps later ... |
| go dh.coreProxy.PortStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, voltha.Port_ETHERNET_UNI, uniPort.portNo, uniPort.operState) |
| } else { |
| //TODO there is no retry mechanism, return error |
| logger.Debugw(ctx, "reconciling - don't notify core about PortStateUpdate", log.Fields{"device-id": dh.deviceID}) |
| } |
| } |
| } |
| } |
| |
| // Disable UniPortState and update core port state accordingly |
| func (dh *deviceHandler) disableUniPortStateUpdate(ctx context.Context) { |
| // compare enableUniPortStateUpdate() above |
| // -> use current restriction to operate only on first UNI port as inherited from actual Py code |
| for uniNo, uniPort := range dh.uniEntityMap { |
| // only if this port is validated for operState transfer |
| if (1<<uniPort.uniID)&activeUniPortStateUpdateMask == (1 << uniPort.uniID) { |
| logger.Infow(ctx, "onuUniPort-forced-OperState-UNKNOWN", log.Fields{"for PortNo": uniNo}) |
| uniPort.setOperState(vc.OperStatus_UNKNOWN) |
| //maybe also use getter functions on uniPort - perhaps later ... |
| go dh.coreProxy.PortStateUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, voltha.Port_ETHERNET_UNI, uniPort.portNo, uniPort.operState) |
| } |
| } |
| } |
| |
| // ONU_Active/Inactive announcement on system KAFKA bus |
| // tried to re-use procedure of oltUpDownIndication from openolt_eventmgr.go with used values from Py code |
| func (dh *deviceHandler) sendOnuOperStateEvent(ctx context.Context, aOperState vc.OperStatus_Types, aDeviceID string, raisedTs int64) { |
| var de voltha.DeviceEvent |
| eventContext := make(map[string]string) |
| //Populating event context |
| // assume giving ParentId in GetDevice twice really gives the ParentDevice (there is no GetParentDevice()...) |
| parentDevice, err := dh.coreProxy.GetDevice(log.WithSpanFromContext(context.TODO(), ctx), dh.parentID, dh.parentID) |
| if err != nil || parentDevice == nil { |
| logger.Errorw(ctx, "Failed to fetch parent device for OnuEvent", |
| log.Fields{"parentID": dh.parentID, "err": err}) |
| } |
| oltSerialNumber := parentDevice.SerialNumber |
| |
| eventContext["pon-id"] = strconv.FormatUint(uint64(dh.pOnuIndication.IntfId), 10) |
| eventContext["onu-id"] = strconv.FormatUint(uint64(dh.pOnuIndication.OnuId), 10) |
| eventContext["serial-number"] = dh.device.SerialNumber |
| eventContext["olt_serial_number"] = oltSerialNumber |
| eventContext["device_id"] = aDeviceID |
| eventContext["registration_id"] = aDeviceID //py: string(device_id)?? |
| logger.Debugw(ctx, "prepare ONU_ACTIVATED event", |
| log.Fields{"device-id": aDeviceID, "EventContext": eventContext}) |
| |
| /* Populating device event body */ |
| de.Context = eventContext |
| de.ResourceId = aDeviceID |
| if aOperState == voltha.OperStatus_ACTIVE { |
| de.DeviceEventName = fmt.Sprintf("%s_%s", cOnuActivatedEvent, "RAISE_EVENT") |
| de.Description = fmt.Sprintf("%s Event - %s - %s", |
| cEventObjectType, cOnuActivatedEvent, "Raised") |
| } else { |
| de.DeviceEventName = fmt.Sprintf("%s_%s", cOnuActivatedEvent, "CLEAR_EVENT") |
| de.Description = fmt.Sprintf("%s Event - %s - %s", |
| cEventObjectType, cOnuActivatedEvent, "Cleared") |
| } |
| /* Send event to KAFKA */ |
| if err := dh.EventProxy.SendDeviceEvent(ctx, &de, equipment, pon, raisedTs); err != nil { |
| logger.Warnw(ctx, "could not send ONU_ACTIVATED event", |
| log.Fields{"device-id": aDeviceID, "error": err}) |
| } |
| logger.Debugw(ctx, "ctx, ONU_ACTIVATED event sent to KAFKA", |
| log.Fields{"device-id": aDeviceID, "with-EventName": de.DeviceEventName}) |
| } |
| |
| // createUniLockFsm initializes and runs the UniLock FSM to transfer the OMCI related commands for port lock/unlock |
| func (dh *deviceHandler) createUniLockFsm(ctx context.Context, aAdminState bool, devEvent OnuDeviceEvent) { |
| chLSFsm := make(chan Message, 2048) |
| var sFsmName string |
| if aAdminState { |
| logger.Debugw(ctx, "createLockStateFSM", log.Fields{"device-id": dh.deviceID}) |
| sFsmName = "LockStateFSM" |
| } else { |
| logger.Debugw(ctx, "createUnlockStateFSM", log.Fields{"device-id": dh.deviceID}) |
| sFsmName = "UnLockStateFSM" |
| } |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice -aborting", log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| pLSFsm := newLockStateFsm(ctx, pDevEntry.PDevOmciCC, aAdminState, devEvent, |
| sFsmName, dh, chLSFsm) |
| if pLSFsm != nil { |
| if aAdminState { |
| dh.pLockStateFsm = pLSFsm |
| } else { |
| dh.pUnlockStateFsm = pLSFsm |
| } |
| dh.runUniLockFsm(ctx, aAdminState) |
| } else { |
| logger.Errorw(ctx, "LockStateFSM could not be created - abort!!", log.Fields{"device-id": dh.deviceID}) |
| } |
| } |
| |
| // runUniLockFsm starts the UniLock FSM to transfer the OMCI related commands for port lock/unlock |
| func (dh *deviceHandler) runUniLockFsm(ctx context.Context, aAdminState bool) { |
| /* Uni Port lock/unlock procedure - |
| ***** should run via 'adminDone' state and generate the argument requested event ***** |
| */ |
| var pLSStatemachine *fsm.FSM |
| if aAdminState { |
| pLSStatemachine = dh.pLockStateFsm.pAdaptFsm.pFsm |
| //make sure the opposite FSM is not running and if so, terminate it as not relevant anymore |
| if (dh.pUnlockStateFsm != nil) && |
| (dh.pUnlockStateFsm.pAdaptFsm.pFsm.Current() != uniStDisabled) { |
| _ = dh.pUnlockStateFsm.pAdaptFsm.pFsm.Event(uniEvReset) |
| } |
| } else { |
| pLSStatemachine = dh.pUnlockStateFsm.pAdaptFsm.pFsm |
| //make sure the opposite FSM is not running and if so, terminate it as not relevant anymore |
| if (dh.pLockStateFsm != nil) && |
| (dh.pLockStateFsm.pAdaptFsm.pFsm.Current() != uniStDisabled) { |
| _ = dh.pLockStateFsm.pAdaptFsm.pFsm.Event(uniEvReset) |
| } |
| } |
| if pLSStatemachine != nil { |
| if pLSStatemachine.Is(uniStDisabled) { |
| if err := pLSStatemachine.Event(uniEvStart); err != nil { |
| logger.Warnw(ctx, "LockStateFSM: can't start", log.Fields{"err": err}) |
| // maybe try a FSM reset and then again ... - TODO!!! |
| } else { |
| /***** LockStateFSM started */ |
| logger.Debugw(ctx, "LockStateFSM started", log.Fields{ |
| "state": pLSStatemachine.Current(), "device-id": dh.deviceID}) |
| } |
| } else { |
| logger.Warnw(ctx, "wrong state of LockStateFSM - want: disabled", log.Fields{ |
| "have": pLSStatemachine.Current(), "device-id": dh.deviceID}) |
| // maybe try a FSM reset and then again ... - TODO!!! |
| } |
| } else { |
| logger.Errorw(ctx, "LockStateFSM StateMachine invalid - cannot be executed!!", log.Fields{"device-id": dh.deviceID}) |
| // maybe try a FSM reset and then again ... - TODO!!! |
| } |
| } |
| |
| //setBackend provides a DB backend for the specified path on the existing KV client |
| func (dh *deviceHandler) setBackend(ctx context.Context, aBasePathKvStore string) *db.Backend { |
| addr := dh.pOpenOnuAc.KVStoreHost + ":" + strconv.Itoa(dh.pOpenOnuAc.KVStorePort) |
| logger.Debugw(ctx, "SetKVStoreBackend", log.Fields{"IpTarget": addr, |
| "BasePathKvStore": aBasePathKvStore, "device-id": dh.deviceID}) |
| kvbackend := &db.Backend{ |
| Client: dh.pOpenOnuAc.kvClient, |
| StoreType: dh.pOpenOnuAc.KVStoreType, |
| /* address config update acc. to [VOL-2736] */ |
| Address: addr, |
| Timeout: dh.pOpenOnuAc.KVStoreTimeout, |
| PathPrefix: aBasePathKvStore} |
| |
| return kvbackend |
| } |
| func (dh *deviceHandler) getFlowOfbFields(ctx context.Context, apFlowItem *ofp.OfpFlowStats, loMatchVlan *uint16, |
| loAddPcp *uint8, loIPProto *uint32) { |
| |
| for _, field := range flow.GetOfbFields(apFlowItem) { |
| switch field.Type { |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_ETH_TYPE: |
| { |
| logger.Debugw(ctx, "flow type EthType", log.Fields{"device-id": dh.deviceID, |
| "EthType": strconv.FormatInt(int64(field.GetEthType()), 16)}) |
| } |
| /* TT related temporary workaround - should not be needed anymore |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_IP_PROTO: |
| { |
| *loIPProto = field.GetIpProto() |
| logger.Debugw("flow type IpProto", log.Fields{"device-id": dh.deviceID, |
| "IpProto": strconv.FormatInt(int64(*loIPProto), 16)}) |
| if *loIPProto == 2 { |
| // some workaround for TT workflow at proto == 2 (IGMP trap) -> ignore the flow |
| // avoids installing invalid EVTOCD rule |
| logger.Debugw("flow type IpProto 2: TT workaround: ignore flow", |
| log.Fields{"device-id": dh.deviceID}) |
| return |
| } |
| } |
| */ |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_VLAN_VID: |
| { |
| *loMatchVlan = uint16(field.GetVlanVid()) |
| loMatchVlanMask := uint16(field.GetVlanVidMask()) |
| if !(*loMatchVlan == uint16(of.OfpVlanId_OFPVID_PRESENT) && |
| loMatchVlanMask == uint16(of.OfpVlanId_OFPVID_PRESENT)) { |
| *loMatchVlan = *loMatchVlan & 0xFFF // not transparent: copy only ID bits |
| } |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "VID": strconv.FormatInt(int64(*loMatchVlan), 16)}) |
| } |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_VLAN_PCP: |
| { |
| *loAddPcp = uint8(field.GetVlanPcp()) |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "PCP": loAddPcp}) |
| } |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_UDP_DST: |
| { |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "UDP-DST": strconv.FormatInt(int64(field.GetUdpDst()), 16)}) |
| } |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_UDP_SRC: |
| { |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "UDP-SRC": strconv.FormatInt(int64(field.GetUdpSrc()), 16)}) |
| } |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_IPV4_DST: |
| { |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "IPv4-DST": field.GetIpv4Dst()}) |
| } |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_IPV4_SRC: |
| { |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "IPv4-SRC": field.GetIpv4Src()}) |
| } |
| case of.OxmOfbFieldTypes_OFPXMT_OFB_METADATA: |
| { |
| logger.Debugw(ctx, "flow field type", log.Fields{"device-id": dh.deviceID, |
| "Metadata": field.GetTableMetadata()}) |
| } |
| /* |
| default: |
| { |
| //all other entires ignored |
| } |
| */ |
| } |
| } //for all OfbFields |
| } |
| |
| func (dh *deviceHandler) getFlowActions(ctx context.Context, apFlowItem *ofp.OfpFlowStats, loSetPcp *uint8, loSetVlan *uint16) { |
| for _, action := range flow.GetActions(apFlowItem) { |
| switch action.Type { |
| /* not used: |
| case of.OfpActionType_OFPAT_OUTPUT: |
| { |
| logger.Debugw("flow action type", log.Fields{"device-id": dh.deviceID, |
| "Output": action.GetOutput()}) |
| } |
| */ |
| case of.OfpActionType_OFPAT_PUSH_VLAN: |
| { |
| logger.Debugw(ctx, "flow action type", log.Fields{"device-id": dh.deviceID, |
| "PushEthType": strconv.FormatInt(int64(action.GetPush().Ethertype), 16)}) |
| } |
| case of.OfpActionType_OFPAT_SET_FIELD: |
| { |
| pActionSetField := action.GetSetField() |
| if pActionSetField.Field.OxmClass != of.OfpOxmClass_OFPXMC_OPENFLOW_BASIC { |
| logger.Warnw(ctx, "flow action SetField invalid OxmClass (ignored)", log.Fields{"device-id": dh.deviceID, |
| "OxcmClass": pActionSetField.Field.OxmClass}) |
| } |
| if pActionSetField.Field.GetOfbField().Type == of.OxmOfbFieldTypes_OFPXMT_OFB_VLAN_VID { |
| *loSetVlan = uint16(pActionSetField.Field.GetOfbField().GetVlanVid()) |
| logger.Debugw(ctx, "flow Set VLAN from SetField action", log.Fields{"device-id": dh.deviceID, |
| "SetVlan": strconv.FormatInt(int64(*loSetVlan), 16)}) |
| } else if pActionSetField.Field.GetOfbField().Type == of.OxmOfbFieldTypes_OFPXMT_OFB_VLAN_PCP { |
| *loSetPcp = uint8(pActionSetField.Field.GetOfbField().GetVlanPcp()) |
| logger.Debugw(ctx, "flow Set PCP from SetField action", log.Fields{"device-id": dh.deviceID, |
| "SetPcp": *loSetPcp}) |
| } else { |
| logger.Warnw(ctx, "flow action SetField invalid FieldType", log.Fields{"device-id": dh.deviceID, |
| "Type": pActionSetField.Field.GetOfbField().Type}) |
| } |
| } |
| /* |
| default: |
| { |
| //all other entires ignored |
| } |
| */ |
| } |
| } //for all Actions |
| } |
| |
| //addFlowItemToUniPort parses the actual flow item to add it to the UniPort |
| func (dh *deviceHandler) addFlowItemToUniPort(ctx context.Context, apFlowItem *ofp.OfpFlowStats, apUniPort *onuUniPort) error { |
| var loSetVlan uint16 = uint16(of.OfpVlanId_OFPVID_NONE) //noValidEntry |
| var loMatchVlan uint16 = uint16(of.OfpVlanId_OFPVID_PRESENT) //reserved VLANID entry |
| var loAddPcp, loSetPcp uint8 |
| var loIPProto uint32 |
| /* the TechProfileId is part of the flow Metadata - compare also comment within |
| * OLT-Adapter:openolt_flowmgr.go |
| * Metadata 8 bytes: |
| * Most Significant 2 Bytes = Inner VLAN |
| * Next 2 Bytes = Tech Profile ID(TPID) |
| * Least Significant 4 Bytes = Port ID |
| * Flow Metadata carries Tech-Profile (TP) ID and is mandatory in all |
| * subscriber related flows. |
| */ |
| |
| metadata := flow.GetMetadataFromWriteMetadataAction(ctx, apFlowItem) |
| if metadata == 0 { |
| logger.Debugw(ctx, "flow-add invalid metadata - abort", |
| log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("flow-add invalid metadata: %s", dh.deviceID) |
| } |
| loTpID := uint8(flow.GetTechProfileIDFromWriteMetaData(ctx, metadata)) |
| loCookie := apFlowItem.GetCookie() |
| loCookieSlice := []uint64{loCookie} |
| logger.Debugw(ctx, "flow-add base indications", log.Fields{"device-id": dh.deviceID, |
| "TechProf-Id": loTpID, "cookie": loCookie}) |
| |
| dh.getFlowOfbFields(ctx, apFlowItem, &loMatchVlan, &loAddPcp, &loIPProto) |
| /* TT related temporary workaround - should not be needed anymore |
| if loIPProto == 2 { |
| // some workaround for TT workflow at proto == 2 (IGMP trap) -> ignore the flow |
| // avoids installing invalid EVTOCD rule |
| logger.Debugw("flow-add type IpProto 2: TT workaround: ignore flow", |
| log.Fields{"device-id": dh.deviceID}) |
| return nil |
| } |
| */ |
| dh.getFlowActions(ctx, apFlowItem, &loSetPcp, &loSetVlan) |
| |
| if loSetVlan == uint16(of.OfpVlanId_OFPVID_NONE) && loMatchVlan != uint16(of.OfpVlanId_OFPVID_PRESENT) { |
| logger.Errorw(ctx, "flow-add aborted - SetVlanId undefined, but MatchVid set", log.Fields{ |
| "device-id": dh.deviceID, "UniPort": apUniPort.portNo, |
| "set_vid": strconv.FormatInt(int64(loSetVlan), 16), |
| "match_vid": strconv.FormatInt(int64(loMatchVlan), 16)}) |
| //TODO!!: Use DeviceId within the error response to rwCore |
| // likewise also in other error response cases to calling components as requested in [VOL-3458] |
| return fmt.Errorf("flow-add Set/Match VlanId inconsistent: %s", dh.deviceID) |
| } |
| if loSetVlan == uint16(of.OfpVlanId_OFPVID_NONE) && loMatchVlan == uint16(of.OfpVlanId_OFPVID_PRESENT) { |
| logger.Debugw(ctx, "flow-add vlan-any/copy", log.Fields{"device-id": dh.deviceID}) |
| loSetVlan = loMatchVlan //both 'transparent' (copy any) |
| } else { |
| //looks like OMCI value 4097 (copyFromOuter - for Uni double tagged) is not supported here |
| if loSetVlan != uint16(of.OfpVlanId_OFPVID_PRESENT) { |
| // not set to transparent |
| loSetVlan &= 0x0FFF //mask VID bits as prerequisite for vlanConfigFsm |
| } |
| logger.Debugw(ctx, "flow-add vlan-set", log.Fields{"device-id": dh.deviceID}) |
| } |
| if _, exist := dh.UniVlanConfigFsmMap[apUniPort.uniID]; exist { |
| return dh.UniVlanConfigFsmMap[apUniPort.uniID].SetUniFlowParams(ctx, loTpID, loCookieSlice, |
| loMatchVlan, loSetVlan, loSetPcp) |
| } |
| return dh.createVlanFilterFsm(ctx, apUniPort, loTpID, loCookieSlice, |
| loMatchVlan, loSetVlan, loSetPcp, OmciVlanFilterAddDone) |
| } |
| |
| //removeFlowItemFromUniPort parses the actual flow item to remove it from the UniPort |
| func (dh *deviceHandler) removeFlowItemFromUniPort(ctx context.Context, apFlowItem *ofp.OfpFlowStats, apUniPort *onuUniPort) error { |
| //optimization and assumption: the flow cookie uniquely identifies the flow and with that the internal rule |
| //hence only the cookie is used here to find the relevant flow and possibly remove the rule |
| //no extra check is done on the rule parameters |
| //accordingly the removal is done only once - for the first found flow with that cookie, even though |
| // at flow creation is not assured, that the same cookie is not configured for different flows - just assumed |
| //additionally it is assumed here, that removal can only be done for one cookie per flow in a sequence (different |
| // from addFlow - where at reconcilement multiple cookies per flow ) can be configured in one sequence) |
| // - some possible 'delete-all' sequence would have to be implemented separately (where the cookies are don't care anyway) |
| loCookie := apFlowItem.GetCookie() |
| logger.Debugw(ctx, "flow-remove base indications", log.Fields{"device-id": dh.deviceID, "cookie": loCookie}) |
| |
| /* TT related temporary workaround - should not be needed anymore |
| for _, field := range flow.GetOfbFields(apFlowItem) { |
| if field.Type == of.OxmOfbFieldTypes_OFPXMT_OFB_IP_PROTO { |
| loIPProto := field.GetIpProto() |
| logger.Debugw(ctx, "flow type IpProto", log.Fields{"device-id": dh.deviceID, |
| "IpProto": strconv.FormatInt(int64(loIPProto), 16)}) |
| if loIPProto == 2 { |
| // some workaround for TT workflow on proto == 2 (IGMP trap) -> the flow was not added, no need to remove |
| logger.Debugw(ctx, "flow-remove type IpProto 2: TT workaround: ignore flow", |
| log.Fields{"device-id": dh.deviceID}) |
| return nil |
| } |
| } |
| } //for all OfbFields |
| */ |
| |
| if _, exist := dh.UniVlanConfigFsmMap[apUniPort.uniID]; exist { |
| return dh.UniVlanConfigFsmMap[apUniPort.uniID].RemoveUniFlowParams(ctx, loCookie) |
| } |
| logger.Debugw(ctx, "flow-remove called, but no flow is configured (no VlanConfigFsm, flow already removed) ", |
| log.Fields{"device-id": dh.deviceID}) |
| //but as we regard the flow as not existing = removed we respond just ok |
| // and treat the reason accordingly (which in the normal removal procedure is initiated by the FSM) |
| go dh.deviceProcStatusUpdate(ctx, OmciVlanFilterRemDone) |
| |
| return nil |
| } |
| |
| // createVlanFilterFsm initializes and runs the VlanFilter FSM to transfer OMCI related VLAN config |
| func (dh *deviceHandler) createVlanFilterFsm(ctx context.Context, apUniPort *onuUniPort, aTpID uint8, aCookieSlice []uint64, |
| aMatchVlan uint16, aSetVlan uint16, aSetPcp uint8, aDevEvent OnuDeviceEvent) error { |
| chVlanFilterFsm := make(chan Message, 2048) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice -aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice for device-id %x - aborting", dh.deviceID) |
| } |
| |
| pVlanFilterFsm := NewUniVlanConfigFsm(ctx, dh, pDevEntry.PDevOmciCC, apUniPort, dh.pOnuTP, |
| pDevEntry.pOnuDB, aTpID, aDevEvent, "UniVlanConfigFsm", chVlanFilterFsm, |
| dh.pOpenOnuAc.AcceptIncrementalEvto, aCookieSlice, aMatchVlan, aSetVlan, aSetPcp) |
| if pVlanFilterFsm != nil { |
| dh.UniVlanConfigFsmMap[apUniPort.uniID] = pVlanFilterFsm |
| pVlanFilterStatemachine := pVlanFilterFsm.pAdaptFsm.pFsm |
| if pVlanFilterStatemachine != nil { |
| if pVlanFilterStatemachine.Is(vlanStDisabled) { |
| if err := pVlanFilterStatemachine.Event(vlanEvStart); err != nil { |
| logger.Warnw(ctx, "UniVlanConfigFsm: can't start", log.Fields{"err": err}) |
| return fmt.Errorf("can't start UniVlanConfigFsm for device-id %x", dh.deviceID) |
| } |
| /***** UniVlanConfigFsm started */ |
| logger.Debugw(ctx, "UniVlanConfigFsm started", log.Fields{ |
| "state": pVlanFilterStatemachine.Current(), "device-id": dh.deviceID, |
| "UniPort": apUniPort.portNo}) |
| } else { |
| logger.Warnw(ctx, "wrong state of UniVlanConfigFsm - want: disabled", log.Fields{ |
| "have": pVlanFilterStatemachine.Current(), "device-id": dh.deviceID}) |
| return fmt.Errorf("uniVlanConfigFsm not in expected disabled state for device-id %x", dh.deviceID) |
| } |
| } else { |
| logger.Errorw(ctx, "UniVlanConfigFsm StateMachine invalid - cannot be executed!!", log.Fields{ |
| "device-id": dh.deviceID}) |
| return fmt.Errorf("uniVlanConfigFsm invalid for device-id %x", dh.deviceID) |
| } |
| } else { |
| logger.Errorw(ctx, "UniVlanConfigFsm could not be created - abort!!", log.Fields{ |
| "device-id": dh.deviceID, "UniPort": apUniPort.portNo}) |
| return fmt.Errorf("uniVlanConfigFsm could not be created for device-id %x", dh.deviceID) |
| } |
| return nil |
| } |
| |
| //VerifyVlanConfigRequest checks on existence of a given uniPort |
| // and starts verification of flow config based on that |
| func (dh *deviceHandler) VerifyVlanConfigRequest(ctx context.Context, aUniID uint8, aTpID uint8) { |
| //ensure that the given uniID is available (configured) in the UniPort class (used for OMCI entities) |
| var pCurrentUniPort *onuUniPort |
| for _, uniPort := range dh.uniEntityMap { |
| // only if this port is validated for operState transfer |
| if uniPort.uniID == uint8(aUniID) { |
| pCurrentUniPort = uniPort |
| break //found - end search loop |
| } |
| } |
| if pCurrentUniPort == nil { |
| logger.Debugw(ctx, "VerifyVlanConfig aborted: requested uniID not found in PortDB", |
| log.Fields{"device-id": dh.deviceID, "uni-id": aUniID}) |
| return |
| } |
| dh.verifyUniVlanConfigRequest(ctx, pCurrentUniPort, aTpID) |
| } |
| |
| //verifyUniVlanConfigRequest checks on existence of flow configuration and starts it accordingly |
| func (dh *deviceHandler) verifyUniVlanConfigRequest(ctx context.Context, apUniPort *onuUniPort, aTpID uint8) { |
| //TODO!! verify and start pending flow configuration |
| //some pending config request my exist in case the UniVlanConfig FSM was already started - with internal data - |
| //but execution was set to 'on hold' as first the TechProfile config had to be applied |
| if pVlanFilterFsm, exist := dh.UniVlanConfigFsmMap[apUniPort.uniID]; exist { |
| //VlanFilterFsm exists and was already started (assumed to wait for TechProfile execution here) |
| pVlanFilterStatemachine := pVlanFilterFsm.pAdaptFsm.pFsm |
| if pVlanFilterStatemachine != nil { |
| //if this was an event of the TP processing that was waited for in the VlanFilterFsm |
| if pVlanFilterFsm.GetWaitingTpID() == aTpID { |
| if pVlanFilterStatemachine.Is(vlanStWaitingTechProf) { |
| if err := pVlanFilterStatemachine.Event(vlanEvContinueConfig); err != nil { |
| logger.Warnw(ctx, "UniVlanConfigFsm: can't continue processing", log.Fields{"err": err, |
| "device-id": dh.deviceID, "UniPort": apUniPort.portNo}) |
| } else { |
| /***** UniVlanConfigFsm continued */ |
| logger.Debugw(ctx, "UniVlanConfigFsm continued", log.Fields{ |
| "state": pVlanFilterStatemachine.Current(), "device-id": dh.deviceID, |
| "UniPort": apUniPort.portNo}) |
| } |
| } else if pVlanFilterStatemachine.Is(vlanStIncrFlowWaitTP) { |
| if err := pVlanFilterStatemachine.Event(vlanEvIncrFlowConfig); err != nil { |
| logger.Warnw(ctx, "UniVlanConfigFsm: can't continue processing", log.Fields{"err": err, |
| "device-id": dh.deviceID, "UniPort": apUniPort.portNo}) |
| } else { |
| /***** UniVlanConfigFsm continued */ |
| logger.Debugw(ctx, "UniVlanConfigFsm continued with incremental flow", log.Fields{ |
| "state": pVlanFilterStatemachine.Current(), "device-id": dh.deviceID, |
| "UniPort": apUniPort.portNo}) |
| } |
| } else { |
| logger.Debugw(ctx, "no state of UniVlanConfigFsm to be continued", log.Fields{ |
| "have": pVlanFilterStatemachine.Current(), "device-id": dh.deviceID, |
| "UniPort": apUniPort.portNo}) |
| } |
| } else { |
| logger.Debugw(ctx, "TechProfile Ready event for TpId that was not waited for in the VlanConfigFsm - continue waiting", log.Fields{ |
| "state": pVlanFilterStatemachine.Current(), "device-id": dh.deviceID, |
| "UniPort": apUniPort.portNo, "techprofile-id (done)": aTpID}) |
| } |
| } else { |
| logger.Debugw(ctx, "UniVlanConfigFsm StateMachine does not exist, no flow processing", log.Fields{ |
| "device-id": dh.deviceID, "UniPort": apUniPort.portNo}) |
| } |
| } // else: nothing to do |
| } |
| |
| //RemoveVlanFilterFsm deletes the stored pointer to the VlanConfigFsm |
| // intention is to provide this method to be called from VlanConfigFsm itself, when resources (and methods!) are cleaned up |
| func (dh *deviceHandler) RemoveVlanFilterFsm(ctx context.Context, apUniPort *onuUniPort) { |
| logger.Debugw(ctx, "remove UniVlanConfigFsm StateMachine", log.Fields{ |
| "device-id": dh.deviceID, "uniPort": apUniPort.portNo}) |
| //save to do, even if entry dows not exist |
| delete(dh.UniVlanConfigFsmMap, apUniPort.uniID) |
| } |
| |
| //storePersUniFlowConfig updates local storage of OnuUniFlowConfig and writes it into kv-store afterwards to have it |
| //available for potential reconcilement |
| |
| func (dh *deviceHandler) storePersUniFlowConfig(ctx context.Context, aUniID uint8, aUniVlanFlowParams *[]uniVlanFlowParams) error { |
| |
| if dh.reconciling { |
| logger.Debugw(ctx, "reconciling - don't store persistent UniFlowConfig", log.Fields{"device-id": dh.deviceID}) |
| return nil |
| } |
| logger.Debugw(ctx, "Store or clear persistent UniFlowConfig", log.Fields{"device-id": dh.deviceID}) |
| |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Errorw(ctx, "No valid OnuDevice - aborting", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| pDevEntry.updateOnuUniFlowConfig(aUniID, aUniVlanFlowParams) |
| |
| pDevEntry.lockOnuKVStoreMutex() |
| defer pDevEntry.unlockOnuKVStoreMutex() |
| |
| // deadline context to ensure completion of background routines waited for |
| //20200721: 10s proved to be less in 8*8 ONU test on local vbox machine with debug, might be further adapted |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(context.Background(), deadline) |
| |
| pDevEntry.resetKvProcessingErrorIndication() |
| var wg sync.WaitGroup |
| wg.Add(1) // for the 1 go routine to finish |
| |
| go pDevEntry.updateOnuKvStore(log.WithSpanFromContext(dctx, ctx), &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "UpdateKvStore") //wait for background process to finish |
| |
| return pDevEntry.getKvProcessingErrorIndication() |
| } |
| |
| func (dh *deviceHandler) waitForCompletion(ctx context.Context, cancel context.CancelFunc, wg *sync.WaitGroup, aCallerIdent string) { |
| defer cancel() //ensure termination of context (may be pro forma) |
| wg.Wait() |
| logger.Debugw(ctx, "WaitGroup processing completed", log.Fields{ |
| "device-id": dh.deviceID, "called from": aCallerIdent}) |
| } |
| |
| func (dh *deviceHandler) deviceReasonUpdate(ctx context.Context, deviceReason uint8, notifyCore bool) error { |
| |
| dh.deviceReason = deviceReason |
| if notifyCore { |
| //TODO with VOL-3045/VOL-3046: return the error and stop further processing at calling position |
| if err := dh.coreProxy.DeviceReasonUpdate(log.WithSpanFromContext(context.TODO(), ctx), dh.deviceID, deviceReasonMap[deviceReason]); err != nil { |
| logger.Errorf(ctx, "DeviceReasonUpdate error: %s", |
| log.Fields{"device-id": dh.deviceID, "error": err}, deviceReasonMap[deviceReason]) |
| return err |
| } |
| logger.Infof(ctx, "DeviceReasonUpdate success: %s - device-id: %s", deviceReasonMap[deviceReason], dh.deviceID) |
| return nil |
| } |
| logger.Infof(ctx, "Don't notify core about DeviceReasonUpdate: %s - device-id: %s", deviceReasonMap[deviceReason], dh.deviceID) |
| return nil |
| } |
| |
| func (dh *deviceHandler) storePersistentData(ctx context.Context) error { |
| pDevEntry := dh.getOnuDeviceEntry(ctx, true) |
| if pDevEntry == nil { |
| logger.Warnw(ctx, "No valid OnuDevice", log.Fields{"device-id": dh.deviceID}) |
| return fmt.Errorf("no valid OnuDevice: %s", dh.deviceID) |
| } |
| pDevEntry.lockOnuKVStoreMutex() |
| defer pDevEntry.unlockOnuKVStoreMutex() |
| |
| deadline := time.Now().Add(dh.pOpenOnuAc.maxTimeoutInterAdapterComm) //allowed run time to finish before execution |
| dctx, cancel := context.WithDeadline(context.Background(), deadline) |
| |
| pDevEntry.resetKvProcessingErrorIndication() |
| var wg sync.WaitGroup |
| wg.Add(1) // for the 1 go routine to finish |
| |
| go pDevEntry.updateOnuKvStore(dctx, &wg) |
| dh.waitForCompletion(ctx, cancel, &wg, "UpdateKvStore") //wait for background process to finish |
| |
| if err := pDevEntry.getKvProcessingErrorIndication(); err != nil { |
| logger.Warnw(ctx, "KV-processing error", log.Fields{"device-id": dh.deviceID, "err": err}) |
| return err |
| } |
| return nil |
| } |
| |
| func (dh *deviceHandler) combineErrorStrings(errS ...error) error { |
| var errStr string = "" |
| for _, err := range errS { |
| if err != nil { |
| errStr = errStr + err.Error() + " " |
| } |
| } |
| if errStr != "" { |
| return fmt.Errorf("%s: %s", errStr, dh.deviceID) |
| } |
| return nil |
| } |
| |
| // getUniPortMEEntityID takes uniPortNo as the input and returns the Entity ID corresponding to this UNI-G ME Instance |
| func (dh *deviceHandler) getUniPortMEEntityID(uniPortNo uint32) (uint16, error) { |
| dh.lockDevice.RLock() |
| defer dh.lockDevice.RUnlock() |
| if uniPort, ok := dh.uniEntityMap[uniPortNo]; ok { |
| return uniPort.entityID, nil |
| } |
| return 0, errors.New("error-fetching-uni-port") |
| } |